My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
2758
>
2300 - Underground Storage Tank Program
>
PR0541416
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2024 1:32:34 PM
Creation date
10/10/2023 12:55:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0541416
PE
2351
FACILITY_ID
FA0023733
FACILITY_NAME
Sunwest Chevron
STREET_NUMBER
2758
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
Ln
City
Lodi
Zip
95242
APN
16646031
CURRENT_STATUS
01
SITE_LOCATION
2758 W Kettleman Ln
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Date: <br />October 17, 2023 <br /> Facility Address: <br /> 2758 W Kettleman Ln, Lodi <br /> Facility Name: <br /> Sunwest Chevron <br />Single-Walled Non-Pressurized Piping <br /> 404 □ V □ R □ COSFailure to conduct 0.1 gph test on single-walled gravity piping biennially or post repair (pre-1984)CCR 2643(e), 2661(f) <br />Other Violations <br /> 2010 □ V □ R □ COSUnlisted General violation See below <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 102 CCR 2711 Failure to submit a complete and accurate application for a permit to operate a UST. <br />OBSERVATION: UST Tank Information forms are not current in the California Environmental Reporting System <br />(CERS). The tank information for tank ID# 10748068-001 is inaccurate. CERS indicates the content is diesel, <br />however, manager Rajesh Pratap stated that the content was changed to biodiesel B20 approximately in <br />January/February 2023. <br />REGULATION GUIDANCE: Any change of information must be updated in CERS within 30 days of the changes. <br />CORRECTIVE ACTION: The tank form was updated at the time of the inspection. <br />This is a minor violation. <br /> 104 CCR 2632(d)(1), 2634(d) Failure to submit a complete and accurate UST Monitoring Plan. <br />OBSERVATION: The monitoring plan is not current. The first and second persons listed as having responsibility are <br />outdated. Per Rajesh Pratap, the managers listed in the monitoring plans are no longer working at the facility. <br />REGULATION GUIDANCE: The monitoring plan must be uploaded to the California Environmental Reporting <br />System (CERS). <br />CORRECTIVE ACTION: The names of the individuals having responsibility were updated in CERS at the time of the <br />inspection. <br />This is a repeat violation, Class II. <br /> 105 CCR 2632(d)(2), 2634(e) Failure to submit a complete and accurate UST Response Plan. <br />OBSERVATION: The response plan is not current. The person listed as having responsibility is outdated. <br />REGULATION GUIDANCE: The response plan must be uploaded to the California Environmental Reporting System <br />(CERS). <br />CORRECTIVE ACTION: Immediately log into CERS, upload the completed form, and submit for review by the EHD. <br />This is a minor violation. <br />FA0023733 PR0541416 SC001 10/17/2023 <br />EHD 23-01 Rev. 12/06/2021 Underground Storage Tank Program OIRPage 4 of 11 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.