Laserfiche WebLink
Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Date: <br />October 17, 2023 <br /> Facility Address: <br /> 2758 W Kettleman Ln, Lodi <br /> Facility Name: <br /> Sunwest Chevron <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 106 CCR 2632(d), 2641(h) Failure to submit and maintain a current facility plot plan / site map. <br />OBSERVATION: An accurate UST Monitoring Site Plan was not submitted. The site map incorrectly indicates that <br />the split tank contains diesel in one compartment. <br />REGULATION GUIDANCE: A site plan must be submitted identifying the locations where monitoring will be <br />performed. The site plan must show the general layout of tanks and clearly identify locations of the following <br />equipment, if installed: 1) monitoring panels; 2) in-tank liquid level probes (if used for leak detection); 3) devices <br />monitoring tank annular spaces or vault; 4) devices monitoring product piping; 5) devices monitoring fill piping; 6) <br />devices monitoring vent piping; 7) devices monitoring vapor recovery piping; 8) devices monitoring vent/transition <br />sumps; 9) devices monitoring under-dispenser containment; 10) line leak detectors; and 11) devices monitoring any <br />other secondary containment areas. <br />CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.calepa.ca.gov/ and upload a copy of the UST Monitoring Site Plan. <br />This is a repeat violation, Class II. <br /> 107 HSC 25292.2; CCR 2711(a)(11) Failure to submit and maintain complete and current financial responsibility <br />documents. <br />1)OBSERVATION: Financial responsibility documents have not been submitted to the EHD. The most recent <br />financial responsibility documents in CERS are dated 9/27/2022. <br />REGULATION GUIDANCE: Current financial responsibility documents are required to be submitted annually. <br />CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.calepa.ca.gov/, and upload the required documents. <br />------------------------------------------------------------- <br />2) OBSERVATION: Current financial responsibility documents were not found on site. <br />REGULATION GUIDANCE: A copy of current financial responsibility documents are required to be maintained on <br />site. <br />CORRECTIVE ACTION: Immediately obtain a copy of the facility's financial responsibility documents and maintain a <br />copy on site. <br />This is a repeat violation, Class II. <br />FA0023733 PR0541416 SC001 10/17/2023 <br />EHD 23-01 Rev. 12/06/2021 Underground Storage Tank Program OIRPage 5 of 11 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD