My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
15
>
2300 - Underground Storage Tank Program
>
PR0231404
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/17/2024 3:49:45 PM
Creation date
11/1/2023 4:25:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0231404
PE
2361
FACILITY_ID
FA0002915
FACILITY_NAME
TRACY MARKET INC
STREET_NUMBER
15
Direction
E
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21435004
CURRENT_STATUS
01
SITE_LOCATION
15 E GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Secondary Containment Testing Report Form <br /> 8. SUMP/UDC TEST <br /> Test Method Developed by ❑ Manufacturer ® Industry Standard ❑ Professional Engineer <br /> Test Type ❑ Pressure ❑ Vacuum M Hydrostatic <br /> Test Equipment Used: Caldwell Level Change Indicator <br /> Sump/UDC ID 87-1 STP 87-2 STP 91 STP VENT Sump <br /> Sump Manufacturer Unknown Unknown Unknown Unknown <br /> Sump Depth (inches) 36 32 30 24 <br /> Sump Bottom to Top of 23 21 16 17 <br /> Highest Pipe Penetration <br /> (inches) <br /> Test Start Time 9:15 AM 9:30 AM 9:40 AM 9:45 AM <br /> Initial Reading 0 0 0 0 <br /> Test End Time 9:45 AM 10:00 Am 10:10 AM 10:15 AM <br /> Final Reading 0 0 0 0 <br /> Change in Reading 0 0 0 0 <br /> Pass Fail Criteria 0 0 0 0 <br /> Tightness Test Results ® Pass ❑ Fail ® Pass ❑ Fail ® Pass ❑ Fail ® Pass ❑ Fail <br /> Sump/UDC ID 87-1 FILL 87-2 FILL 91 FILL <br /> Sump Manufacturer Unknown Unknown Unknown <br /> Sump Depth (inches) 41 35 26 <br /> Sump Bottom to Top of 0 0 0 <br /> Highest Pipe Penetration <br /> (inches) <br /> Test Start Time 8:55 AM 9:00 AM 9:05 AM <br /> Initial Reading 0 0 0 <br /> Test End Time 9:25 AM 9:30 AM 9:35 AM <br /> Final Reading 0 0 0 <br /> Change in Reading 0 0 0 <br /> Pass Fail Criteria 0 0 0 <br /> Tightness Test Results ® Pass ❑ Fail M Pass ❑ Fail M Pass ❑ Fail ❑ Pass ❑ Fail <br /> Additional copies of this page may be attached. <br /> All tests marked "Fail"and any repairs made before or during the tightness test must be described in <br /> the COMMENTS section. <br /> Page 3of5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.