TGI — Indoor Air, Ambient Air, Sub-Slab Vapor, and Soil Vapor 04ARCADIS <br /> Sampling for Analysis via USEPA Compendium Method TO-10A <br /> Rev: 0 1 Rev Date: March 10, 2023 <br /> Soil Vapor Collection of the Sample <br /> Sub-slab and soil vapor sample assemblies are nearly <br /> identical. Soil vapor probes typically are equipped with COMPRESSION NUT <br /> 7W0-WAY <br /> permanent sample assemblies. The sub-slab vapor VALVE AND FERRULE SET <br /> point/Vapor Pin TM and connected silicone tubing 7TELBONN-LINED <br /> shown in the Purge Configuration show to the right are <br /> TEDLAR <br /> not present in soil vapor probe assemblies. THREE-WAY VALVE BAG <br /> WITH 1/4''ID A <br /> SILICONE TUBING <br /> 1. Pre-assemble the sample train for each sub-slab CONNECTIONS <br /> point to be sampled (Vapor Pin°with barb fitting). <br /> PURGE SYRINGE <br /> Cut an approximate 18-inch length and a 1-inch 1/4''11)SILICONE 1 <br /> length of Teflon or Teflon-lined 1/4-inch OD tubing. TUBING <br /> Cut a 2-inch piece of 1/4-inch silicone tubing. <br /> Connect the silicone tubing to one end of the 18- SUB-SLAB POINT PURGE <br /> W BS LAB VAPOR <br /> inch length of tubing. Connect a stainless-steel INT/VAPORPIN" CONFIGURATION WITH <br /> SEPARATE SAMPLE <br /> two-way valve with compression fittings to the <br /> other side of the Teflon tubing. Connect the 1-inch piece of Teflon tubing to the other side of the <br /> two-way valve. Connect a compression nut and ferrule set to the other end of the 1-inch piece of <br /> Teflon tubing for the connection to the sub-slab PUF absorbent tube fitting detailed in step 4. <br /> Connect the silicone tubing to the sub-slab point. <br /> For both sub-slab vapor and soil vapor sampling: <br /> 2. Connect 1-inch pieces of silicone tubing to each side of the three-way valve. Connect the 60-mL <br /> syringe to one side of the three-way valve, a TedlarO bag to another side of the three-way valve, <br /> and the sub-slab point assembly to the last side of the three-way valve; shown in the Purge <br /> Configuration diagram above. <br /> 3. Open the two-way valve and purge three volumes of air from the sample assembly at a rate of <br /> <200 milliliters per minute (mL/min) into the Tedlar° bag. Approximately 10-mL of air is in 1 foot of <br /> 1/4-inch OD tubing. Discharge purged air into the Tedlar°bag. <br /> 4. After purging, close the two-way valve and remove <br /> COMPRESSION <br /> the purge assembly. Connect the PUF sorbent tube TW°-WAY NUT WITH <br /> with sub-slab fitting (and quartz filter assembly if VALVE FERRULESET <br /> TELFON OR TEFLON- <br /> using)to the sub-slab point sample assembly LINED14"CDTUN- <br /> LINED 1J4"CD TUBING <br /> PUF ABSORBENT TUBE <br /> compression fitting. Connect the tapered end of theP° I SUB-SLAB ADAPTER <br /> PUF sorbent tube to the calibrated low flow air ABSORBENT <br /> TUBE <br /> pump using a short length of silicone tubing as <br /> LOW AIR <br /> shown in the Sample Configuration diagram to the <br /> 1/4"ID swcoNE <br /> right. TUBING <br /> 3. Turn on the low flow air sampler. Record the start <br /> time on the sample form. Ensure the low flow <br /> sua-sloe TO-10A SUB-SLAB VAPOR <br /> VAPOR POINT/ SAMPLE CONFIGURATION <br /> sampler is reading correctly according to the VAPOR PIN <br /> WITH SEPARATE PURGE <br /> flow rate pre-determined by the laboratory and <br /> project team. <br /> Printed copies of this Technical Guidance Instruction are uncontrolled. Page 10 of 14 <br />