My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023 ARCADIS REPORT
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
2023-2026 Reports
>
COMPLIANCE INFO_2023 ARCADIS REPORT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/31/2024 10:25:53 AM
Creation date
11/22/2023 8:56:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023 ARCADIS REPORT
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\cfield
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
254
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TGI - Indoor Air, Ambient Air, Sub-Slab Vapor, and Soil Vapor 04ARCADIS <br /> Sampling for Analysis via USEPA Compendium Method TO-10A <br /> Rev: 0 1 Rev Date: March 10, 2023 <br /> 4. Record the following weather information on the sampling form (use a hand-held weather meter or other <br /> suitable information source [e.g., weatherunderground.com] to obtain the following information): <br /> o Ambient air temperature <br /> o Indoor air temperature <br /> o Barometric pressure <br /> o Wind speed <br /> o Relative humidity <br /> o Significant recent precipitation <br /> o Snow/ice cover <br /> Termination of Ambient Air, Indoor Air, Sub-Slab Vapor, and Soil Vapor Sample Collection <br /> 1. At the end of the specified sample duration turn off the low volume air sampler and record the time on the <br /> sample form. For soil gas samples, close the valve on the sub-slab or soil vapor sample assembly. <br /> 2. Remove the PUF cartridge with clean gloved hands and immediately wrap the cartridge in the original <br /> material. Wrap in foil, place in a small bubble bag and place inside the sealed container. Put the container <br /> in the large bubble bag and then into the re-sealable bag and close. If using the quartz filter, remove and <br /> place inside the sealed container. Label the re-sealable bag. <br /> 3. Package the PUF cartridges in the laboratory provided boxes - preservation with ice or frozen gel <br /> packs is required during shipment. <br /> 4. For sub-slab vapor samples, remove the sub-slab sample assembly. Replace the Vapor Pin° <br /> cap and cover. For soil vapor samples, replace the cap on the end of the tubing and coil into the <br /> well annulus. Replace the well cover. <br /> 5. Complete the COC forms and sample labels provided by the laboratory as directed. Instructions <br /> on how to determine the flow rate for the COC is below. <br /> 6. Complete the COC form; copy, photograph, or scan a version for the project file (if possible); and place the <br /> form in the shipping container. Close the shipping container and affix the custody seal to the container <br /> closure. <br /> 7. Transmit media via courier delivery service to laboratory for analysis. <br /> Determination of Flow Rate <br /> To determine the total volume of air that flowed through the low volume air pump during the sample duration: <br /> 1. Connect the low volume air sampler inlet to the flow calibrator using flexible silicone tubing. <br /> 2. Connect the tapered end of the calibration sorbent tube to the opposite end of the flow calibrator using <br /> flexible silicone tubing. <br /> Printed copies of this Technical Guidance Instruction are uncontrolled. Page 11 of 14 <br />
The URL can be used to link to this page
Your browser does not support the video tag.