My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_FINAL WMU FU-23 DESIGN RPT & CONCURRENCE LTRS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
2023-2025 Reports
>
COMPLIANCE INFO_FINAL WMU FU-23 DESIGN RPT & CONCURRENCE LTRS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2023 8:51:58 AM
Creation date
11/30/2023 9:10:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
FINAL WMU FU-23 DESIGN RPT & CONCURRENCE LTRS
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\cfield
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
257
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> <br />Forward Landfill WMU FU-23 ATTACHMENT A 1 LEAK LOCATION TESTING <br /> ATTACHMENT A LEAK LOCATION TESTING PART 1 GENERAL 1.1 WORK INCLUDED A. This section includes required methods for leak location testing on an HDPE Geomembrane. Tests shall be performed on both the geomembrane in an uncovered state and on the geomembrane once the overlying granular drainage material and protective operations layers are placed. 1.2 REFERENCES <br />A. ASTM D6747 – Standard Guide for Selection of Techniques for Electrical <br />Detection of Potential Leak Paths in Geomembranes <br />B. ASTM D7002 – Standard Practice for Leak Location on Exposed <br />Geomembranes Using the Water Puddle System <br /> 1.3 QUALIFICATIONS A. Leak Location Contractors shall demonstrate successful experience in performing large-scale leak location surveys for geomembranes alone and geomembranes covered with soil. The Leak Location Contractor shall have performed at least 10,000,000 square feet of surveys in the previous three years. 1.4 SUBMITTALS A. Submit qualifications of proposed Leak Location Contractor to QA/QC CONSULTANT and OWNER. PART 2 DEMONSTRATION 2.1 GENERAL A. The preparations, operation of the system, and survey parameters shall be verified by performing tests over two artificial leaks. An artificial leak is an electrical simulation of a leak consisting of an area of metal the size of the desired leak connected to an insulated wire. The other end of the wire is connected to a ground electrode. The test parameters and procedures shall be: 1. An artificial leak with a diameter of 0.64 cm (0.25-inch) shall be placed at ground surface and an artificial leak with a diameter of 1.27 cm (0.5-inch) shall be buried at a depth of two-feet below ground surface. 2. A line of data shall be taken and recorded directly over the artificial leak for a distance of at least 20-feet in front and behind the artificial leak with the artificial leak disconnected to measure and quantify the background noise level (BN). The background noise level shall be defined as the difference between the maximum and minimum measured voltage with the artificial leak disconnected. 3. The artificial leak shall be connected and leak location measurements shall be made and recorded along closely-spaced parallel lines in the vicinity of