Laserfiche WebLink
SAN J O A U I Environmental Health Department <br /> COUNTY <br /> Grrarness grows here, <br /> Food Program Service Request Inspection Report <br /> Name of Facility: Sombrero Taqueria LLC Date: 12/17/2024 <br /> Address: 678 N WILSON WAY, STOCKTON 95205 <br /> Requestor: Telephone: ()- <br /> Program Element: 1603- FOOD PLAN CHECK(1 HR MIN) Request#: SR2400703 <br /> Inspection Type: 521 - Plan Check/Report Review <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code commencing with section 7; <br /> 113700.All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and have the potential to cause foodborne illness.All major violations must be corrected immediately.Non-compliance may warrant immediate <br /> #35 Equipment/Utensils Approved and in Good Repair <br /> OBSERVATIONS:The hand sink in the restroom is offset to the left and cracked sealant. Reposition and secure the sink. <br /> Reseal using silicone or other commercial food safe sealant. Correct Prior to operation. <br /> -------------------------------------------------------- <br /> The 2-comp sink and prep sink were observed with damaged sealant. Clean wall and reseal the sinks using silicone or other <br /> commercial food safe sealant. Correct prior to operation. <br /> CALCODE DESCRIPTION:All utensils and equipment shall be fully operative and in good repair.(114175).All utensils and equipment <br /> shall be approved, installed properly,and meet applicable standards.(114130, 114130.1, 114130.2, 114130.3, 114130.4, 114130.5, <br /> 114132, 114133, 114137, 114139, 114153, 114155, 114163, 114165, 114167, 114169, 114172, 114177, 114180, 114182) <br /> #38 Approved/Sufficient Ventilation and Lighting <br /> OBSERVATIONS:Observed grease buildup on the exhaust hood. Clean and degrease hood between hood services to ensure <br /> proper removal of heat, grease, smoke, and vapors. Correct today. <br /> CALCODE DESCRIPTION:Exhaust hoods shall be provided to remove toxic gases, heat,grease,vapors and smoke and be approved <br /> by the local building department.Canopy-type hoods shall extend 6"beyond all cooking equipment.All areas shall have sufficient <br /> ventilation to facilitate proper food storage.Toilet rooms shall be vented to the outside air by a screened openable window,an air shaft, <br /> or a light-switch activated exhaust fan,consistent with local building codes.(114149, 114149.1)Adequate lighting shall be provided in <br /> all areas to facilitate cleaning and inspection. Light fixtures in areas where open food is stored,served,prepared,and where utensils <br /> are washed shall be of shatterproof construction or protected with light shields.(114149.2, 114149.3, 114252, 114252.1) <br /> #45 Floors,Walls,Ceilings; Clean and Maintained <br /> OBSERVATIONS:Observed the wall and seal behind the mop sink with black buildup. Clean and sanitize this area and <br /> maintain as needed. Correct prior to operation. <br /> -------------------------------------------------------- <br /> The tiles at the walk-in freezer entrance are damaged. Repair floor with like materials. Correct within 30 days. <br /> CALCODE DESCRIPTION:The walls/ceilings shall have durable,smooth,nonabsorbent,light-colored,and washable surfaces. All <br /> floor surfaces,other than the customer service areas,shall be approved,smooth,durable and made of nonabsorbent material that is <br /> easily cleanable.Approved base coving shall be provided in all areas,except customer service areas and where food is stored in <br /> original unopened containers. Food facilities shall be fully enclosed. All food facilities shall be kept clean and in good repair. (114143 <br /> (d), 114266, 114268, 114268.1, 114271, 114272) <br /> FA0002460 SR2400703 SC521 12/17/2024 <br /> EHD 16-23 Rev.09/16/2020 Page 1 of 2 Food Program Service Request Inspection Report <br />