Laserfiche WebLink
'oP SAN JOQQUIN Environmental Health Department <br /> z <br /> COUNTY Jasjit Kang , REHS , Director <br /> c �P Muniappa Naidu, REHS , Assistant Director <br /> ' 6F:60 �6 Greatness grows here . <br /> PROGRAM COORDINATORS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Steven Shih , REHS <br /> Elena Manzo , REHS <br /> Natalia Subbotnikova , REHS <br /> January 4 , 2024 <br /> RYAN BROWNLEE amended <br /> ABLE MAINTENANCE INC <br /> 3224 REGIONAL PARKWAY <br /> SANTA ROSA , CA 95403 <br /> Ryan@ablemaintenance . com <br /> Re : SAFEWAY FUEL CENTER # 1769 SR0086810 <br /> 2802 COUNTRY CLUB BLVD , STOCKTON , CA 95204 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a permit to do the following on the underground storage tank ( UST) system at the above <br /> noted address : <br /> • Replace all product piping . <br /> • Replace all UDCs ( under dispenser containment sumps) with conversion frames . <br /> • Replace all turbine sumps . <br /> • Replace all direct bury spill containers . <br /> Replace all overfill prevention flapper valve . <br /> • Replace the monitoring panel . <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire district , the San Joaquin Valley Air Pollution Control District , and the local <br /> community development department for any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for written approval <br /> prior to commencing work . All new submittals supersede previous ones . <br /> 3 . Email notification to ust(cDsigov . org to arrange the following inspection appointments . <br /> All appointments must be scheduled at least 48 hours in advance . <br /> a . Primary piping soap test of all piping joints and penetrations ( product , vapor recovery , vent , <br /> and chase) and pressure testing hydrostatically at 150 % of design operating pressure or <br /> pneumatically at 110 % of operating pressure . If the calculated test pressure is less than 40 <br /> psi , 40 psi shall be used as the test pressure . Testing must be conducted in accordance <br /> with manufacturer specifications and California code of Regulations (CCR) Title 23 . <br /> b . Secondary piping test : Soap test of all piping joints and penetrations ( product , vapor <br /> recovery , vent , and chase) and pressure test in accordance with manufacturer <br /> specifications . <br /> c . Verification of secondary piping slope for all piping ( product , vapor recovery , vent , and <br /> chase) at 1 /8 inch per foot or greater , to a containment sump with an audible/visual alarm . <br /> Piping slope must be adequate at the start of this inspection , with all piping in its final <br /> position and ready to be backfilled without adjustment per the manufacturer' s installation <br /> instructions . <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 T 209 468-3420 1 F 209 464-0138 1 www . sjgov . org/ehd <br />