Laserfiche WebLink
3.3 Description of All Current On-Site Potential and/or Known Above and Below <br /> Ground Sources of Contamination Identified at the Project Site: Presently, there are no <br /> underground storage tanks on the property and visual inspection did not produce any evidence of <br /> buried containers, as well as no odors that would be associated with buried chemical tanks. <br /> There are three above ground fuel tanks on the site which are permitted under the San Joaquin Valley <br /> Air Pollution Control District. On-site water dissipates through either percolation or evaporation via an <br /> on site retention pond. Stormwater flows through a sand and oil separator prior to flowing into the pond. <br /> 3.4 Description of All Past Off-Site Potential and/or Known Above and Below Ground <br /> Sources of Contamination Identified In the Area of the Project Site: Past off-site potential <br /> for contamination is low. The subject parcel is located in an agricultural neighborhood. The land use <br /> has historically been used as a residence and for agricultural purposes. <br /> 3.5 Description of all Present Off-Site Potential and/or Known Above and Below Ground Sources <br /> of Contamination Identified in the Area of the Project Site: Present off-site potential for <br /> contamination is low. (See Appendix for case studies.) <br /> 4.0 EVALUATION OF PAST AND CURRENT SOURCES OF <br /> CONTAMINATION IDENTIFIED AT OR NEAR THE SITE AND <br /> RECOMMENDATIONS FOR FURTHER ACTION: <br /> 4.1 Evaluation of each potential and/or known source of contamination identified for any real <br /> and/or potential threat to human health and the environment: The depth to ground water in this area <br /> is approximately 110 feet. Due to this depth, any pesticides, insecticides, and fertilizers used on the <br /> property in the past or present would have a minimal impact to the ground water. All existing and future <br /> homesibuildings will be served by private wells. <br /> 5.0 CONCLUSIONS AND RECOMMENDATIONS SECTION: <br /> 5.1 Discussion of the Above Evaluation: There are fuel storage tanks on this site that are permitted <br /> through the San Joaquin Valley Air Pollution Control District. Thus the potential for contamination is <br /> low. There are pesticides, insecticides, and fertilizers used on the site but the depth to groundwater is <br /> such that the impact is minimal. No mitigation measures are recommended. <br /> 5.2 The Report is inclusive: All information in this report does not reference any other documents that <br /> are not contained in this report. <br /> 5.3 Report was signed dated and stamped: See below. <br /> 5.4 'Che report was prepared within Six Months of the Date of the Subm i ttal: This report was <br /> originally generated in February, 2024. <br /> 5.5 "Che Attachment/Appendices Contain Sufficient Documentation to Support Claims Made in <br /> Report: See Appendix. <br /> 2 <br />