COMPLIANCE INFO_2024 Q1 WATER QUALITY RPT
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
2023-2026 Reports
>
COMPLIANCE INFO_2024 Q1 WATER QUALITY RPT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/31/2024 10:50:50 AM
Creation date
5/31/2024 8:38:48 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024 Q1 WATER QUALITY RPT
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\cfield
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2577
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> <br />4683 Chabot Dr., #200, Pleasanton, CA 94588 | 925-426-0080 <br /> <br />Environmental Consultants & Contractors <br /> <br /> <br />April 12, 2024 <br />Project No. 01221044.09 <br /> <br /> <br />Mr. Brendan Kenny <br />Central Valley Regional Water Quality Control Board <br />11020 Sun Center Drive <br />Rancho Cordova, CA 95670 <br /> <br /> <br />Subject: FIRST QUARTER 2024 LFG GCCS UPDATE <br /> FORWARD LANDFILL <br /> MANTECA, CALIFORNIA 95336 <br /> <br />Dear Mr. Kenny: <br /> <br />On behalf of Republic Services and Forward, Inc. (Forward), SCS Engineers (SCS) is pleased to <br />submit the First Quarter 2024 Corrective Action Program Update for the landfill gas (LFG) collection <br />and control system (GCCS) at the Forward Landfill (Landfill or Site), located in Manteca, California. <br />Information herein is being provided to the Central Valley Regional Water Quality Control Board <br />(CVRWQCB) as part of the directives set forth in Cleanup and Abatement Order (CAO) R5-2017-0703 <br />(Order). Please see the details for compliance and operations below. <br />ORDER COMPLIANCE <br />The following is a summary of the first quarter 2024 activities performed as they pertain to the <br />performance and improvements of the GCCS: <br /> Continued monitoring of twelve (12) perimeter gas monitoring probes. The current probe <br />network subject to the CAO includes wells GP-1A through GP-6A, and GP-10 through GP-15. <br />All CAO probes were monitored on March 20, 2024 and March 22, 2024 as part of SCS Field <br />Services (SCSFS) site-wide LFG monitoring and onsite structure testing event. Note that <br />testing, monitoring protocols, and reporting were performed in general conformance with <br />Title 27 California Code of Regulations (CCR) Article 6. The monitoring results for the CAO <br />probes are presented in attached Table 1. <br /> <br /> Per the Order, based on the first quarter monitoring results, probe intervals GP-10D, GP-10M, <br />and GP-10S will require annual TO-15 sampling due to a detection of methane greater than 1 <br />percent of 48.4, 56.2, and 56.7, respectively. Probes GP-1AD, GP-2AD, GP-4AD, GP-10D, GP- <br />10M, GP-10S, GP-11D, GP-11M, GP-11S, GP-12D, GP-12M and GP-12S will require annual <br />TO-15 sampling due to VOC concentrations above 10 parts per billion by volume (ppbv). The <br />TO-15 sampling of these probes is conducted on an annual basis and will be sampled later in <br />the year, in conformance with the Order. <br /> <br />COMPLIANCE TESTING INSTRUMENTATION AND METHODS <br />Testing for methane gas, oxygen gas, carbon dioxide gas and pressure was performed using a <br />Landtec GEM-5000 Gas Analyzer calibrated to methane gas. The instrument measures combustible <br />gas concentrations as a percentage by volume (0 to 100 percent) in the gas sampled. The detection
The URL can be used to link to this page
Your browser does not support the video tag.