My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BECKMAN
>
351
>
2300 - Underground Storage Tank Program
>
PR0231310
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 11:32:37 AM
Creation date
6/6/2024 2:29:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0231310
PE
2361 - UST FACILITY
FACILITY_ID
FA0003773
FACILITY_NAME
VAN DE POL ENT INC/PACIFIC PRIDE
STREET_NUMBER
351
Direction
N
STREET_NAME
BECKMAN
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04903015
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\lsauers1
Supplemental fields
Site Address
351 N BECKMAN RD LODI 95240
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A dOAQU1N Environmental Health Department <br /> COUNTY <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> VAN DE POL ENT INC/PACIFIC PRIDE 351 N BECKMAN RD LODI June 25 2024 <br /> 87 CA Code of Regulations 2060021-Striker plate installed and positioned correctly. ❑OUT ❑R ❑COS <br /> 2631(c),2662(d) <br /> 88 CA Code of Regulations 2060007-Primary and secondary containment designed and constructed to an engineering ❑OUT ❑R ❑COS <br /> 2631(b&d),2666(b&e) specification. <br /> 89 CA Health and Safety 2060008-Enhanced leak detection testing performed before the tank is placed in use ❑OUT ❑R ❑COS <br /> Code 25290.10) <br /> 90 CA Code of Regulations 2060029-SW piping has been upgraded to continuously monitored DW piping when replacement ❑OUT ❑R ❑COS <br /> 2666(b)(2) or repair needed <br /> 91 CA Health and Safety 2010-Administration/Documentation-General ❑OUT ❑R ❑COS <br /> Code 25291(e) <br /> 92 2015-Administrative/Documentation-General Local Ordinance ❑OUT ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 5 CA Code of Regulations 2632(d),2641(h)2030041 -A current facility plot plan is maintained and has been submitted. <br /> OBSERVATION:An accurate UST Monitoring Site Plan was not submitted.The plan shows sensors in the fill sumps <br /> of all 5 tanks;the sensors are no longer connected to the panel. <br /> REGULATION GUIDANCE:A site plan must be submitted identifying the locations where monitoring will be performed. <br /> The site plan must show the general layout of tanks and clearly identify locations of the following equipment, if <br /> installed: 1) monitoring panels; 2)in-tank liquid level probes(if used for leak detection); 3)devices monitoring tank <br /> annular spaces or vault;4)devices monitoring product piping; 5)devices monitoring fill piping; 6)devices monitoring <br /> vent piping; 7)devices monitoring vapor recovery piping; 8)devices monitoring vent/transition sumps; 9)devices <br /> monitoring under-dispenser containment; 10)line leak detectors; and 11)devices monitoring any other secondary <br /> containment areas. <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov/ and upload a copy of the UST Monitoring Site Plan. <br /> This is (Minor)Violation. <br /> 10 CA Code of Regulations 2638(c), 2638(d)2030074-Annual Monitoring System Certification Form to the CUPA within <br /> 30 days of completion of the test. <br /> OBSERVATION:Annual monitoring system certification and leak detector testing was performed on 06/23/2023 and a <br /> test report was submitted on 07/27/2023, 4 days late. <br /> REGULATION GUIDANCE:A copy of the test report must be submitted within 30 days of the tests. <br /> CORRECTIVE ACTION: Take all necessary precautions to ensure testing and submittal of test reports are performed <br /> in a timely manner. <br /> This is(Minor)Violation. <br /> 50 CA Code of Regulations 2635, 2637.1, 2665, 2712 2060020-Spill buckets meet requirements, have been tested as <br /> required, and records kept for 36 mths(TCR 9a). <br /> OBSERVATION:The Diesel (tank 005)spill container failed when tested. <br /> REGULATION GUIDANCE:All spill containers shall have a minimum capacity of five gallons and be capable of <br /> containing a spill or overfill until it is detected or cleaned up. <br /> FA0003773 PR0231310 SCO01 06/25/2024 <br /> EHD Rev.12/06/2021 Page 5 of 7 CP22-UST FULL OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.