A dOAQU1N Environmental Health Department <br /> COUNTY <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> UNITED#5447 1 1469 E HAMMER LN, STOCKTON i Uly 11 2024 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 7 CA Code of Regulations 2715(a)(1)(B), 2715(a)(3)2010003-Owner/Operator submitted DO form and/or informed the <br /> CUPA of any change(s)within 30 days (TCR 10). <br /> OBSERVATION:A new designated operator, Garrett Warren, began conducting inspections on 5/24/24 and notification <br /> was not provided to the EHD within 30 days of the change. <br /> REGULATION GUIDANCE:The owner or operator shall submit a"Designated Underground Storage Tank Operator <br /> Identification Form" no later than 30 days after any change in the designated UST operator(s). <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov and upload the notification identifying all the designated operators for this facility. <br /> This is (Minor)Violation. <br /> 28 CA Code of Regulations 2638(a), 2641 Q)2030043- Leak detection equipment properly installed, calibrated, operated, <br /> and maintained (TCR 9d). <br /> 1.)OBSERVATION:At the time of inspection, Mechanical Leak Detector 99 LD 2000 located in 87 North &South <br /> tanks were not able to detect a leak at the earliest opportunity. <br /> REGULATION GUIDANCE:All monitoring equipment shall be installed, calibrated, operated, and maintained in <br /> accordance with manufacturer's instructions, and certified for operability, proper operating condition, and proper <br /> calibration. <br /> CORRECTIVE ACTION: Service Technician replaced 87 North&South tanks with a new like for like 99 LD 2000 leak <br /> detector. <br /> This was corrected on site. <br /> ------------------------------------------------------------------------------------------------------------------ <br /> 2.)OBSERVATION: <br /> OBSERVATION: At time of inspection, the monitoring panel Veeder Root TLS-350 was not maintained in accordance <br /> with manufacturer's instructions due to facility's usage of the Franklin Fueling sensor S404 in UDC 3/4 AND <br /> Beaudreau BEI 406 sensor in UDC 1/2, 5/6, and 7/8. <br /> - Per Veeder Root, only sensors manufactured by Veeder Root are UL Listed and approved for their TLS-350 <br /> monitoring panel. <br /> REGULATION GUIDANCE:All monitoring equipment shall be installed, calibrated, operated, and maintained in <br /> accordance with manufacturer's instructions, and certified for operability, proper operating condition, and proper <br /> calibration. <br /> CORRECTIVE ACTION: Ensure that all leak detection equipment is properly programmed and maintained at all times. <br /> This is (Class 2)Violation. <br /> 54 CA Code of Regulations 2631, 2640.1, 2665, 2711 2030007-Documentation of compatibility for UST system <br /> FA0001570 PR0231126 SCO01 07/11/2024 <br /> EHD Rev.12/06/2021 Page 6 of 8 CP22-UST FULL OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />