Laserfiche WebLink
NOTE: INDICATES ITEMS FOUND ON bp <br /> MATERIALS LIST SHEETS FM-1 & FM-2 <br /> NOTES: UST INSTALLATION <br /> MANUFACTURER SUPPLIED 14 TANK LIFTING 42" DIA. FILL SUMP 1. SLOPE CONCRETE AWAY FROM ALL MANHOLES 1" RISE OVER 12" RUN. <br /> 18'x8-3/4"x8' DEAD MAN (TYP. OF 6) LUGS (TYP.) 2. FIBER REINFORCEMENT TO BE USED. PREMIX UNIFORMLY THROUGHOUT <br /> CONCRETE. <br /> 3. REINFORCING BARS TO BE NO LESS THAN 2"AND NO MORE THAN 4" FROM <br /> EINFOR <br /> 48" DIA. TURBINE SUMP LENGTH. PLACE REBAR 6" FROM SIDES OF BOX. <br /> 22" DIA. MANWAY 5. SINGLE 1" CONDUIT TO EACH SUBMERSIBLE PUMP. PROVIDE SEAL-OFF AT SUMP <br /> MONITOR 42" DIA FILL SUMP & BUILDING WIRING TROUGH. CONTAINS LINE VOLTAGE WIRING. ALL CONDUIT <br /> RISER 15 PENETRATIONS MUST BE MADE WITH ROBROY PVC COATED CONDUIT ONLY.ONE <br /> 1" STANDARD MONITORING HOMERUN CONDUIT TO EACH TANK. FOR STANDARD ARCO <br /> MONITORING DEVICES, LOOP CONTAINMENT SUMP SENSORS, PLLD, VAC <br /> b ci <br /> r, — 00\ SENSORS &TANK GAUGE TO TANK INTERSTITIAL SENSOR LOCATION AND BP WEST COAST PRODUCTS,LLC <br /> T HOMERUN TO BLDG. PROVIDE SEAL-OFFS IN BUILDING & PRIOR TO LEAVING <br /> ..0 <br /> VAPOR HAZARDOUS AREA. ROUTE TO INTRINSICALLY SAFE TROUGH IN BUILDING. <br /> VAP' <br /> ®RECOVERY RISER CONDUITS SHALL CONTAIN ONLY LOW VOLTAGE WIRING FOR SENSORS. ALL <br /> ANCHOR STRAP TANK GAUGE LOCATION CONDUIT PENETRATIONS MUST BE MADE WITH ROBROY PVC COATED CONDUIT <br /> FILL RISER 14 LOCATION (TYP.) ONLY. <br /> STRAP CHANNEL 6. USE PEA GRAVEL CONSISTING OF NATURALLY ROUNDED AGGREGATE, MIN/," & <br /> THROUGH SUMP MAX OF,/4" IN SIZE, FREE OF CLAY, SLAG, CINDERS, OR DEBRIS. ALL <br /> SUBSTITUTES MUST BE APPROVED BY MANUFACTURER'S & OWNER'S FIELD <br /> REPRESENTATIVE. <br /> 7. TANK PAD MINIMUM 2'-0" OFF OUTSIDE WALLS OF TANKS, AND MUST COVER THE <br /> FOOTPRINT OF THE TANKS. REQUIRED TO PROVIDE FOR PROPER TANK HOLD <br /> BRINE RESERVOIR AND TANK GAUGE FILL RISER DOWN, AND TO PREVENT ACCIDENTAL DRILLING INTO TANK. <br /> INTERSTITIAL MONITOR LOCATION VAPOR RECOVERY 8. CUT CORNER WHERE MEETING ASPHALT PAVING ONLY. SQUARE CORNERS <br /> RISER WHERE MEETING CONCRETE. NO. DATE REVISION DESCRIPTION <br /> 3 9. REFER TO SITE SPECIFIC PLANS FOR ACTUAL PIPE RUNS & NUMBER OF <br /> 55'-V4" PRODUCT LINES (1 OR 2 PER UST SUMP). 1/30/2024 INITIAL ISSUE <br /> 10. TURBINE AND FILL SIDE SUMP CONFIGURATION SHOWN IS TYPICAL. FOR 2/7/2024 ISSUE FOR PERMIT <br /> SPECIFIC DESIGN CRITERIA AT THESE SUMPS SEE ACCOMPANYING TANK <br /> INSTALLATION SITE PLAN & SUMP DETAIL DRAWINGS NOTED ABOVE. <br /> 11. TANK ANCHORING, CONSULT LOCAL REGULATION; VERIFY WITH OWNER'S 3/26/2024 REVISED PER C.E.H.COMMENTS <br /> REPRESENTATIVE. <br /> 12. OVERFLOW PROTECTION: LIST OVERFLOW COMPLIANCE IS ACHIEVED BY USE OF <br /> OVERFLOW PREVENTION DROP TUBE FLAPPER VALVE SET AT 95% AND IS IN A6 5/3/2024 REVISED PER C.E.H.COMMENTS <br /> ACCORDANCE WITH FEDERAL AND STATE GUIDELINES FOR LIST OVERFILL <br /> REQUIREMENTS. ZL <br /> 13. AN OVERFILL ALARM AND ACKNOWLEDGE SWITCH TIED INTO THE VEEDER ROOT ZL <br /> AUTOMATIC TANK GAUGE SYSTEM. THE MONITORING SYSTEM PROVIDES AN <br /> AUDIBLE AND VISUAL ALARM WHEN THE TANK(S)ARE FILLED TO THE 90% LEVEL. <br /> UNDERGROUND 24,000/6,000 SPLIT GAL TANK PLAN VIEW SEAL: <br /> SCALE: 1/4" l'-O" <br /> A B A B <br /> T-4 T-4 T-3 T-3 THE RECIPIENT OF THESE MATERIALS UND.ERSTANDS THAT <br /> COPYRIGHT IN THE MATERIALS IS OWNED BY BP,AND ALSO,THAT <br /> THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS <br /> 8"THICK, 4000 PSI FIBER INFORMATION OF Bp ACCORDINGLY,THE RECIPIENT AGREES TO <br /> E rA Y­BN��A �B RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NO <br /> REINFORCED CONCRETE TANK 2 3 TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND <br /> T-5 T-5 T-5 T-3 T-3 T-4 T-4 T-3 T-3 FT-5.lFT-5.1 T-3 T-3 FU THEIR AGREES NOT TO MAKE COPIES OF THE MATERIALS.THE <br /> SLAB, SEE SHEET FS-1 FOR SPECS RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED <br /> PU RPOSE FOR WHICH BP HAS MADE THE MATERIALS AVAILABLE,AN <br /> RECIPIENT AGREES TO RETURN A L MATERIALS TO BP EITHER U <br /> TANK LEVEL GAUGE W/4" FLOAT KIT. COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUE <br /> 3 4 13 1 OVERFILL ALARM AT 90% CAPACITY 12 13 13 12 13 10 11 TYP. OF BP,WHICHEVER COMES FIRST. <br /> PIPE AND TANK DESIGN DISCLAIMER: <br /> BP DOES NOT AND CANNOT WARRANT THAT THE PLANS FOR <br /> PET OLEUM STORAGE AND DISPENSING ARE COMPLIANT ITH ALL <br /> LEGAL REQUIREMENTS THAT EXIST OR AS THEY MAY BE APPLIED IN <br /> 6 THE FUTURE.NOR DOES BP WARRANT THAT A FUELING STO RAGE <br /> AN D D LIVERY SYSTEM CONSTRUCTED IN CONFORMITY WITH THES <br /> 6 PLANS WI L BE FREE OF ALL LEAKS.YOU ARE ACCORDINGLY <br /> STRONGLY ENCOURAGED TO CONSULT WITH A FUELING STATION <br /> ENGINEER OF YOUR CHOOSING TO INDEPENDENTLY EVALUATE <br /> WHETHER THESE PLANS ARE TRULY SUFFICIENT FOR <br /> CONSTRUCTING THE STORAGE AND DELIVERY SYSTEM AT YOUR <br /> ;__�18)9 J-BOX D F— DEVELOPMENT INFORMATION: <br /> 1 COND. LOOP TO SUMP 187 a- <br /> uJ <br /> 6 <br /> I 1::�1::� 1111 UNDERGROUNDSTORAGE <br /> 4" FRP RISER TO GRADE 11 � 'ii <br /> --Odt2m <br /> C? Z) TANKSTANDARDS <br /> HOME RUN TO BUILDING rn 00 <br /> ELEMENT TP01 <br /> DUAL FLOAT HYDROSTATIC <br /> 203 V-15.0 2023 SERIES <br /> MONITORING SENSOR <br /> NOTE: SLOPE SIDES OF TANK HOLE (USE <br /> OF SLOPING MUST BE RECEIVE PRIOR - -—-—- <br /> 01 1 I=muum!=00: <br /> APPROVAL ON INDIVIDUAL SITE BASIC <br /> u) <br /> FROM "BP") OR USE SHORING FOR ALL OVERFILL PROTECTION TT <br /> TANK EXCAVATIONS IN ACCORDANCE DROP SET AT 95% TANK LEVEL GAUGE W/4" FLOAT KIT. 15 <br /> WITH OSHA 1926 SUBPART P, OSHA (TYP.) OVERFILL ALARM AT 90% CAPACITY 6 <br /> c:) <br /> STANDARDS EXCAVATIONS; FINAL RULE 6K PRE STOCKTON, CA 95206 <br /> 6 <br /> OCTOBER 1, 1989 <br /> 4K R`EGULAR <br /> A 1�1. <br /> DESIGNED BY: ALLIANCE Z&DM: <br /> Y' AAK <br /> 4'-0" MAX. ONLY IF 2" MIN. 5-1/2" MAX. 511 /' <br /> CONDITIONS PERMIT — U CHECKED BY: BP REPM: <br /> T_ C�T )<:�T)c�?T )C�5T)c�?T DRAWN BY: ALLIANCE PM: <br /> TAF <br /> '�XM��0/K <br /> Z'�</ CA-4795 <br /> 7 INSTALLED OVER <br /> BACKFILL WITH PEA GRAVEL COMPACTED SOIL log TRAPPER SCREEN (TYP.) DRAWING TITLE: <br /> PER TANK MANUFACTURER 7 2' MIN. 55-9 3/4" 2' MIN. �10) <br /> SPECIFICATIONS. (TYP.) __'w_ (�� "0 11- i.. 111.i 24,000/6,000 GALLON <br /> "'Iv END OF TANK STEEL STRIKER PLATE TYP. UNDER ALL UST INSTALLATION <br /> OPENINGS W/ MANWAYS ON FIBERGLASS TANK <br /> (BY TANK MANUFACTURER) SHEET NO: <br /> UNDERGROUND 24,000/6,000 SPLIT GAL TANK - ELEVATION VIEW <br /> BSCALE: 1/4" = l'-O" <br />