My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
4607
>
2300 - Underground Storage Tank Program
>
PR2500817
>
INSTALL_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2026 12:59:00 PM
Creation date
7/18/2024 2:58:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2024
RECORD_ID
PR2500817
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0004996
FACILITY_NAME
AIRPORT PETROLEUM, LLC
STREET_NUMBER
4607
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
Stockton
Zip
95206
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
4607 S AIRPORT WAY Stockton 95206
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
784
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
bp <br /> 8" 81, 81, 81, 8" 8" 8" 8" <br /> PRESSURE VACUUM VENT PRESSURE VACUUM VENT <br /> CAPS (SEE NOTE BELOW) CAPS (SEE NOTE BELOW) <br /> A <br /> D 24 ATMOSPHERE VENT CAP ATMOSPHERE VENT CAP 24 <br /> SERVICEABLE VAPOR SENSOR GROUP <br /> 2 PIN CONNECTOR OF CABLE (FROM <br /> 183 186 2" GALVANIZED KIT)ATTACHES TO CCVP VALVE <br /> UNION & NIPPLES 2" GALVANIZED 183 186 CANISTER SUPPORT BRACKET AND FASTENERS <br /> VEEDER-ROOT CARBON CANISTER VAPOR UNION & NIPPLES (FROM KIT) <br /> POLISHER CANISTER WEIGHT APPROX 70 CANISTER SUPPORT STUDS W/NUTS (3 EA <br /> LBS. SEE FOUNDATION DESIGN CRITE�IA <br /> S I DE) <br /> BELOW INSTALL ONLY ON THE 87-OCTANE <br /> VENT RISER. DO NOT INSTALL ON DIESEL <br /> RISER IF EXISTING VEEDER-ROOT CARBON CANISTER VAPOR POLISHER <br /> CANISTER WEIGHT APPROX. 70 LBS. SEE <br /> EXPLOSION PROOF J-BOX 218 FOUNDATION DESIGN CRITERIA BELOW <br /> MOUNTED TO POST U) _43 INSTALL ONLY ON THE 87-OCTANE VENT RISER. DO ARCO <br /> Lu NOT INSTALL ON DIESEL RISER IF EXISTING <br /> 0 BP WEST COAST PRODUCTS,LLC <br /> 0 <br /> 0 LL <br /> �! < 189 EXPLOSION PROOF J-BOX MOUNTED TO POST <br /> U) � 2 <br /> z D <br /> MANUFACTURER SUPPLIED 0 Lu Z 0 <br /> i <br /> MOUNTING TUBING x Lu Lu ui <br /> INSTALLING CANISTEP ONTO BPACKET 0 Lu > co <br /> z 3: — 0 Lu MANUFACTURER SUPPLIED MOUNTING TUBING <br /> 00 Lu I-_ I-_ 2 <br /> C-) _j cf) Z 0 <br /> I o LLJ 0 ILL] <br /> CANISTER OPERABILITY TEST PORT o Lu U) 0 4L <br /> U) �__ LU o <br /> > <br /> 0 z Lu LLJ Z <br /> >< ui z IL _j <br /> 2" SCH. 40 GALV. STEEL < 0- U) ILL! < ui <br /> *MAINTAIN CLEARANCE IN A DIRECT 183 w 2 > Of 1,, 2" SCH. 40 GALV. STEEL VENT RISER <br /> LINE, TO ALLOW FOR CONNECTION OF VENT RISER PAINT TO D 0 b �-- _j CD �__ ILL PAINT TO MATCH SITE CONDITIONS <br /> TESTING APPARATUS. uj o -I Z _j -1 T_ <br /> MATCH SITE CONDITIONS N Lu [-L 04 0 NO. DATE REVISION DESCRIPTION <br /> 2 1.- Dj- <br /> 3: v (o > Lu W Z T LLI 1/30/2024 INITIAL ISSUE <br /> 0 FASTEN VENT RISER TO FRAME W/2" LLJ LL1 z <br /> 3-WAY LOCKING BALL VALVE TO BE LOCKED IN OPEN _j STAINLESS STEEL U-BOLT, 3/8"0 T U_ 0 U) 0 FASTEN VENT RISER TO FRAME W/2" <br /> LLJ LU (D < C) < U) U) Z� 2/7/2024 ISSUE FOR PERMIT <br /> POSITION IN NORMAL OPERATING MODE. I.- co U Z STAINLESS STEEL U-BOLT, 3/8"0 HOLE W/ LOCK <br /> HOLE W/ LOCK WASHER HEX NUT. ui Lu z <br /> &5 ui z: W 0� 0 Lu WASHER HEX NUT. TEST EACH RISER FOR 2/27/2024 REVISED PER C.E.H.COMMENTS <br /> TEST EACH RISER FOR ELECTRICAL w F_ Z� <br /> Of 0 CONTINUITY TO VENT RACK (TYP.) 2 U) 2 F- ELECTRICAL CONTINUITY TO VENT RACK(TYP.) <br /> LU Z D U) Fn 0 Z� 3/26/2024 REVISED PER C.E.H.COMMENTS <br /> BRANCH CONNECTION FROM VENT RIDER MUST BE 13- ui Lu z _j <br /> INSTALLED LEVEL OR SLOPED BACK TO THE TANKS Gf) 0 T_ 0 < <br /> uj o CD L) <br /> lo� C) 2" TEE WITH 1/4"TEST PORT T <br /> < UJ FITTING AND 1/4" PLUG (TYP.) U) 2 2" TEE WITH 1/4"TEST PORT <br /> > 10� �-- 0 FITTING AND 1/4" PLUG (TYP.) <br /> Z U- of <br /> 2" SCH. 40 GALVANIZED STEEL (��_ 2 LL <br /> LD < ED <br /> RISER. PAINT PER SPECS (TYP.) C.0 LJJ 0 <br /> T uj <br /> - w C) 9 <br /> 2" TEE WITH 1/4"TEST PORT 2 U) 2-IN-1 SENSOR BOX 217 217 2-IN-1 SENSOR BOX <br /> FITTING AND 1/4" PLUG (TYP.) D U) BOLTED GROUND A <br /> Z CONNECTION TO VENT RACK SEAL: <br /> o EXPLOSION PROOFJ-BOX 189 <br /> < <br /> 2-IN-1 SENSOR BOX 217 MOUNTED TO POST 189 EXPLOSION PROOF J-BOX MOUNTED TO POST <br /> z 2" OPENINGS WATERTIGHT <br /> 0 COMPRESSION PASS THRU <br /> HYDROSTATIC SENSOR INSIDE PRIMARY 212 MINIMUM 2,500 PSI 0 (TYP.) <br /> MANOMETER RESERVOIR ATTACHED TO SUMP CONCRETE FOUNDATION SEAL OFF 191 ANOMETER HOUSING 191 SEAL OFF <br /> PER MANUFACTURER'S M <br /> 10" THICK r 71 10" THICK CONCRETE SLAB <br /> __j SPECIFICATIONS. <br /> CONCRETE SLAB <br /> GRADE <br /> 71 7_1 GRADE <br /> c\I GRADE r M )r mr <br /> 6"WIDE DETECTABLE UNDERGROUND <br /> TIFF_'Lh <br /> MARKING TAPE BURIED 6"-12" BELOW 'A CONFIDENTIALITY STATEMENT: <br /> —�c I i I rr___ 0 f"_� <br /> FINISHED GRADE: EMPIRE#31-143 71H I7� 1 777-1 4 #4 BARE STRANDED CU 4 77% X f77j I 77j 177" <br /> THE ATERIALS CONTAIN PRI <br /> 1xx GROUND WIRE TO TANK INFOMMATION OF Bp A <br /> INSTALL (1) 1" CONDUIT 16-- <br /> R THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT <br /> 2" FLEX FIELD GROUND ROD 7 S <br /> 2" BELLxMALE ADAPTER (TYP.) TO MONITORING PANEL TO DI �LOSE TH ATERIALS TO ANY OTHE R PARTY AND <br /> 14t CONNECTOR FURTHER AGREES N M TO MAKE COPIES OF THE MATERIALS.THE <br /> It IN BUILDING #4 BARE STRANDED CU RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED <br /> (TYP.) N q INSTALL (1) 1" CONDUIT TO P RPOSE FOR WHICH BP HAS MADE THE MATERIALS AVAILABLE,AN <br /> GROUND WIRE TO TANK RECIPIENT AGREES TO RETURN A L MATERIALS TO BP EITHER UPON <br /> 3" FRIP BONDED FITTING 126 16 MONITORING PANEL IN BUILDING COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST <br /> FIELD GROUND ROD 4' OF BP,WHICHEVER COMES FIRST. <br /> W/TEST PORT (TYP.) 4 HYDROSTATIC SENSOR INSIDE 4 4 <br /> PRIMARY MANOMETER 212 < PIPE AND TANK DESIGN DISCLAIMER: <br /> 2" INSIDE 3" DOUBLE WALL FRIP < BP DOES NOT AND CANNOT WARRANT THAT THE PLANS FOR <br /> RESERVOIR ATTACHED TO SUMP PET OLEUM STORAGE AND DISPENSING ARE COMPLIANT WITH ALL <br /> VENT LINE. SEE NOTE BELOW. 142 1 8 HYDROSTATIC SENSOR INSIDE PRIMARY LEGAL REQUIREMENTS THAT EXIST OR AS THEY MAY BE APPLIED IN <br /> 2" SCHEID 40 BLACK IRON 2" FLEX CONNECTOR (TYP 174 THE FUTURE.NOR DOES BP WARRANT THAT A FUELING STORAGE <br /> MANOMETER RESERVOIR ATTACHED TO SUMP AND DELIVERY SYSTEM ONSTRUCTED IN CONFORMITY WITH THIES <br /> ELBOW BY GC 2" INSIDE 3" DOUBLE WALL FRIP VENT 142 PLANS WI L BE FREE OF ALL LEAKS.YOU ARE ACCORDINGLY <br /> STRONGLY ENCOURAGED TO CONSULT WITH A FUELING STATION <br /> LINE. SLOPE TO TANK AT 1/8" PER FOOT 142 14 174 2" FLEX CONNECTOR (TYP.) <br /> WHETHER THESE PLANS ARE TRULY SUFFICIENT FO <br /> CONSTRUCTING THE STORAGE AND DELIVERY SYSTEM AT YOUR <br /> DOUBLE WALL VENT CONTAINMENT NON-DISCRIMINATING MINIMUM. SEE NOTE BELOW. (TYP.) SUMP FILLED WITH PROPYLENE LIQUID SENSOR NON-DISCRIMINATING STATION. <br /> SUMP FILLED WITH PROPYLENE LIQUID SENSOR �,AIIL DOUBLE WALL VENT CONTAINMENT <br /> GLYCOL INTERSTITIAL FLUID, 4 LIQUID SENSOR NON-DISCRIMINATING 202 DOUBLE WALL VENT CONTAINMENT GLYCOL INTERSTITIAL FLUID, DEVELOPMENT INFORMATION: <br /> SUPPLIED BY BRAVO ONLY A SECTION A-A 111 SUMP FILLED WITH PROPYLENE SUPPLIED BY BRAVO ONLY <br /> V-16" GLYCOL INTERSTITIAL FLUID, SECTION B-B UNDERGROUNDSTORAGE <br /> COMPACTED OR NATIVE SOIL (TYPICAL) SUPPLIED BY BRAVO ONLY TANKSTANDARDS <br /> 7'-91 ELEMENT TP01 <br /> SECTION C-C_ 2 NOTES: V-15.0 2023 SERIES <br /> 10" MINIMUM 2,500 PSI c IN ORDER TO PROVIDE MECHANICAL FLEXIBILITY WITHIN THE RIGID PIPING SYSTEM, <br /> CONCRETE FOUNDATION PROVIDE AT LEAST 4 FEET OF STRAIGHT PIPE RUN BEFORE A CHANGE IN DIRECTION OF 30 <br /> SEE DETAILIA' PER MANUFACTURER'S DEGREES OR MORE. [NFPA 30A(2012)§5.3.3(2)], [IFC (2015) §5703.6.9.11,[3 RCNY§3403.6.9.11, SITE ADDRESS: <br /> SPECIFICATIONS. [CFC (2016) §5703.6.9.11. <br /> 10" THICK CONCRETE SLAB zi 1 " < zi THE VENT CONFIGURATION SHOWN IS IN ACCORDANCE WITH CP-201 THE NUMBER OF VENT <br /> ,�7 VENT PIPING MOUNTING RACK <br /> VAPOR SENSOR 4� co CAPS AT ANY GDF SHALL NOT PERMIT AN ADDITIVE LEAK RATE OF MORE THAN .17 CHIF AT 21, <br /> OPERABILITY OF WATER COLUMN. MAX ALLOWED WITHOUT MANIFOLDING IS (3). STOCKTON, CA 95206 <br /> INTRINSICALLY SAFE---\,, TEST PORT m I EXPLOSION PROOF J-BOX 189 NOTE: <br /> VALVE ASSEMBLY GROUP MOUNTED TO POST < 0 VEEDER-ROOT CARBON CANISTER THE VENT DISCHARGE SHALL BE LOCATED SO THAT VAPORS ARE RELEASED AT A SAFE POINT <br /> VAPOR POLISHER TO BE LOCATED IN OUTSIDE OF BUILDINGS AND NOT LESS THAN 12 FT (3.6 M)ABOVE THE ADJACENT GROUND <br /> m 2" BELLxMALE ADAPTER (TYP.) 147 'd CONFORMANCE WITH MANUFACTURERS LEVEL. VAPORS SHALL BE DISCHARGED UPWARD OR HORIZONTALLY AWAY FROM ADJACENT <br /> TEST PORT VALVE < K�A/X WALLS. VENT OUTLETS SHALL BE LOCATED SO THAT VAPORS WILL NOT BE TRAPPED BY DESIGNED BY: AAK ALLIANCE Z&DM: <br /> D 00\ INSTALLATION MANUAL, LATEST CARB EAVES OR OTHER OBSTRUCTIONS AND SHALL BE AT LEAST 5 FT (1.5 M) FROM BUILDING <br /> LIQUID SENSOR 0 EXECUTIVE ORDER VR-204 AND ALL OPENINGS. VENTS SHALL BE INSTALLED IN ACCORDANCE WITH [NFPA 30 (2012) §5.7.21, [IFC CHECKED BY: BP REPM: <br /> 1771\/\ <br /> SERVICEABLE NON-DISCRIMINATING <X>< APPLICABLE STATE AND LOCAL CODES. <br /> VAPOR SENSOR 0 lei 3, < zi (2015) §5704.2.7.3.31, [3 RCNY§2206.7.9.2.2.11, [CFC (2016) §5704.2.7.3.3]. DRAWN BY: TAF ALLIANCE PM: <br /> I \ D 3" FRP BONDED FITTING W/ 126 zi VENT RISERS SHOULD STAND NO LESS THAN 3' FROM OUTSIDE EDGE OF CURB VERSION: PROJECT NO: <br /> ACTIVATED------, TEST PORT (TYP.) Al NOTE CA-4795 <br /> SERVICEABLE CARBON BED ;�I - `_ HYDROSTATIC SEN.SOR MAINTAIN A 5 FOOT CLEARANCE TO <br /> FILTER ELEMENT 2" SW FRIP BONDED 121 7. . 1-� T �T- 212 INSIDE PRIMARY GRADE AROUND CARBON CANISTER DESIGN CRITERIA- PER 2007 CBC DRAWING TITLE: <br /> ENTRY FITTING z]< zi 0. 0 MANOMETER RESERVOIR VAPOR POLISHER FOOTPRINT SEISMIC LOADS VENT SUMP <br /> < ATTACHED TO SUMP <br /> 2" SINGLE WALL FRIP <br /> 142 , SITE INFORMATION IMPORTANCE: 1 SITE CLASS D DETAILS <br /> _1_4 VENT LINE SDOUBLE WALL VENT <br /> 2" INSIDE 3" DOUBLE ,CONTAINMENT SUMP FILLED BASIC RESISTING <br /> CANISTER WALL FRIP VENT LINES 142 148 WITH PROPYLENE GLYCOL SYSTEM: R=2 0=2 SD1=1.0 SDS=1.83 SHEET NO: <br /> INTERSTITIAL FLUID, (REF: ASCE 7-05 Cd=2.5 <br /> OPERABILITY TEST PORT (VACUUM MONITORED) lt�J SUPPLIED BY BRAVO ONLY TABLE 15.4-2) <br /> (BASE SHEAR EQ. (MAX. BASE (MIN. BASE SHEAR <br /> Lu Lu Lu Lu Lu C DESIGN BASE 12.8-2) SHEAR EQ. 12.8-2) EQ. 12.8-5&6 <br /> Z Z Z Z Z Z Z Z Z Z <br /> Lu w w w w SHEAR: 0.92W V=Csw V=SD1W/TR/I V=.5SlW/R/I <br /> DETAIL 'A' SECTION D-D PLAN VIEW '03 :3 :3 :3 :3 <br /> SCALE: NONE SCALE: NONE > > > > > V=0.92W V=1.25W V=O.25W FT� 8 <br /> _j co co cp co <br />
The URL can be used to link to this page
Your browser does not support the video tag.