My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
4607
>
2300 - Underground Storage Tank Program
>
PR2500817
>
INSTALL_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2026 12:59:00 PM
Creation date
7/18/2024 2:58:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2024
RECORD_ID
PR2500817
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0004996
FACILITY_NAME
AIRPORT PETROLEUM, LLC
STREET_NUMBER
4607
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
Stockton
Zip
95206
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
4607 S AIRPORT WAY Stockton 95206
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
784
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6"0 STRAIGHT PIPE BOLLARD bp <br /> FILLED WITH CONCRETE 91 <br /> 6" WIDE DETECTABLE UNDERGROUND (EXTENDED DEPTH) <br /> MARKING TAPE BURIED 6"-12" BELOW <br /> FINISHED GRADE: EMPIRE#31-143 CONCRETE PAVING PAINT TOP 1/3, BP YELLOW" <br /> PAINT BOTTOM 2/3, BP PEARL-\ 6 0 <br /> 4 4 q' I <br /> 4 4 DISPENSERS AT GRADE <br /> 2� z ZO 2� 6"o <br /> PEA GRAVEL <br /> BACKFILL CONCRETE MOUND (TYP.) <br /> DRIVE SLAB <br /> 142 148 <br /> co <br /> —2" OR 3" DW FRP <br /> VAPOR RETURN LINE <br /> �'L6'� <br /> 2" INSIDE 3" D.W. FRP. <br /> 6" 12" 10" 6" PRODUCT PIPING X < I <br /> I X- <br /> 38" < <br /> \X, <br /> ARCO <br /> NATIVE SOIL <br /> �/x <br /> VAPOR RECOVERY IN SEPARATE COMBINED VAPOR RECOVERY AND <br /> TRENCH ALTERNATIVE PRODUCT PIPING TRENCH <br /> BP WEST COAST PRODUCTS,LLC <br /> V-16"O MIN. <br /> NOTE: 2,500 PSI CONCRETE FOUNDATIONS SHOWN ARE <br /> NOTE: IN COMBINED TRENCH, MIN. 12" MINIMUM REQUIREMENTS; LOCAL BUILDING CODES <br /> FOR ILLUSTRATION PURPOSES, A BLENDING GASOLINE BETWEEN STAGE 11 & PRODUCT OR FROST LINE MAY REQUIRE GREATER DEPTH <br /> OPTION IS SHOWN. FOR A COMBINED DIESEL OPTION, PIPING (C.L.) <br /> ADDITIONAL PIPING IS REQUIRED. 2016 CA FIRE CODE SECTION 2303.1.1 PROTECTION OF DISPENSING DEVICES: <br /> WHERE DISPENSING DEVICES ARE MOUNTED AT GRADE, THEY SHALL BE PROTECTED AT EACH END WITH A <br /> MINIMUM OF TWO CONCRETE FILLED STEEL POSTS, 6 INCHES IN DIAMETER, HAVING A MINIMUM 3 FEET DEEP <br /> _F�l R�EN�CH FOOTING NOT LESS THAN 15 INCHES IN DIAMETER, AND PROJECTING ABOVE GRADE AT A MINIMUM OF 3 <br /> sc��Z� FEET AND BE LOCATED NOT LESS THAN 4 FEET NOR MORE THAN 5 FEET FROM FUEL DISPENSERS OR POINT <br /> OF SALE DEVICES, OR EQUIVALENT MEANS APPROVED BY THE FIRE CHIEF. <br /> NO. DATE REVISION DESCRIPTION <br /> 2016 CA FIRE CODE SECTION 2306.7.3 MOUNTING OF DISPENSERS: <br /> DISPENSING DEVICES EXCEPT THOSE INSTALLED ON TOP OF A PROTECTED ABOVE GROUND TANK THAT 1/30/2024 INITIAL ISSUE <br /> QUALIFIES AS VEHICLE IMPACT RESISTANT, SHALL BE PROTECTED AGAINST PHYSICAL DAMAGE FROM <br /> VEHICLES BY MOUNTING ON A CONCRETE ISLANDS 6 INCHES OR MORE IN HEIGHT, OR SHALL BE OTHERWISE 2/7/2024 ISSUE FOR PERMIT <br /> BE SUITABLY PROTECTED IN ACCORDANCE WITH SECTION 312.............. <br /> 2" FRIP VAPOR RETURN LEG 142 NOTE: THIS DETAIL TO BE USED WHEN DISPENSERS ARE MOUNTED AT GRADE OR WHEN THE <br /> CROSSOVER DROPS FROM EACH DISPENSER ",_�To OTHER DISPENSERS DISPENSER ISLANDS ARE LESS THAN 6 INCHES IN HEIGHT <br /> 2" INSIDE 3" FRP PRODUCT PIPING 142 148 <br /> CONCRETE MOUND—, <br /> (TYP.) <br /> CROSSOVERS DROPS AT MAIN HEADERS (TYP.) J* 3'-8" (TYP.) 00, 3'-0" SEAL: <br /> �01 __7 �00 <br /> TYPICAL DISPENSER — <br /> TO TANKS 'Off (ACTUAL FOOTPRINT MAY VARY) <br /> 2 <br /> (.0 <br /> cl I <br /> w <br /> Z <br /> =i 0 <br /> oo� 20 ( 'UA_� <br /> w NOTE: WHEN DISPENSERS ARE INSTALLED CONFIDENTIALITY STATEMENT: <br /> TO OTHER DISPENSERS I-_ ON ISLANDS USE STANDARD LENGTH T E RECIPIENT OF THESE MATERIA S UNDERSTANDS THAT <br /> z COPYRIGHT IN THE MATERIALS IS OWNED BY BP,AND ALSO,THAT <br /> THE ATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS <br /> w NFPA 4"0 U-SHAPED BOLLARD INFOMMATION OF Bp ACCORDINGLY,THE RECIPIENT AGREES TO <br /> 3" FRIP VAPOR RETURN MANIFOLD TO TANKS 148 0 RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NO <br /> TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND <br /> FU THEIR AGREES NOT TO MAKE COPIES OF THE MATERIALS.THE <br /> RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED <br /> DISPENSERS ON ISLAND P RPOSE FOR WHICH BP HAS MADE THE MATERIALS AVAILABLE,AN <br /> RUCIPIENT AGREES TO RETURN ALL MATERIALS TO BP EITHER UPON <br /> COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST <br /> o F BP,WHICHEVER COMES FIRST. <br /> NOTE: INDICATES ITEMS <br /> RifbEEANE)rTAN&DESWbNFD�ffaLAMERLANS FOR <br /> PIPING CROSSOVER FOUND ON MATERIALS LIST PETROLEUM STORAGE AN DISPENSING ARE COMPLIANT WITH ALL <br /> LEGAL REQUIREMENTS THAT EXIST OR AS THEY MAY BE APPLIED IN <br /> SCALE: N.T.S. SHEET FM-1 & FM-2 THE FUTURE.NOR DOES BP WARRANT THAT A FUELING STORAGE <br /> *—Ts AND D LIVERY SYSTEM CONSTRUCTED IN CONFORMITY WITH THES <br /> PLANS WI L BE FREE OF ALL LEAKS.YOU ARE ACCORDINGLY <br /> STRONGLY ENCOURAGED TO CONSULT WITH A FUELING STATION <br /> ENGINEER OF YOUR CHOOSING TO INDEPENDENTLY EVALUATE <br /> WHETHER THESE PLANS ARE TRULY SUFFICIENT FO <br /> CONSTRUCTING THE STORAGE AND DELIVERY SYSTEM AT YOUR <br /> STATION. <br /> NOTE: <br /> ACTUAL NUMBER OF FIRE 113'-0" DEVELOPMENT INFORMATION: <br /> 69'-8" EXTINGUISHERS TO MEET <br /> LOCAL REQUIREMENTS .0, 1 01-olt 31'-0" 31'-0" J* 31'-0" 1 01-olt e_ UNDERGROUNDSTORAGE <br /> TANKSTANDARDS <br /> BUILDING SIDE ELEMENT TPO1 <br /> 4'-73., 5' ill <br /> 4 20' 20' 20' -(4 LINE OF CANOPY FACE ABOVE V-15.0 2023 SERIES <br /> SITE ADDRESS: <br /> THS SDE <br /> DISPENSER SHOWS 4607 S. AIRPORT WAY <br /> Lj-j <br /> El El DISPENSERS AT <br /> Lj-j <br /> INSTAILL CABINET GRADE INSTAILL CABINET STOCKTON, CA 95206 <br /> 0 0 PIC UNIT ON CANOPY ON CANOPY PC UHT <br /> -(�F NEEDED COLUMN (TYP.) COLUMN (TYP.) <br /> (IF NEEDED' <br /> 9 9 1? '7 _,_j <br /> ci I N I__ E�' <br /> 04 = 0 <br /> L'i DESIGNED BY: ALLIANCE Z&DM: <br /> u THS SIDE AAK <br /> SHOWS CHECKED BY: BP REPM: <br /> o===o DISPENSERS ON <br /> DRAWN BY: TAR ALLIANCE PM: <br /> STANDS El <br /> 7 <br /> VERSION: PROJECT NO: <br /> CA-4795 <br /> DISP�NSER DRAWING TITLE: <br /> MISCELLANEOUS <br /> DETAILS <br /> LL= <br /> RECOMMENDED BMP NOTE: <br /> EXCEPT FOR WHERL HLOUiRLD h' ACTUAL NUMBER OF FIRE CONSULT WITH MAINTENANCE SHEET NO: <br /> AUTHORTY HAVNIS JURISUCTION EXTINGUISHERS TO MEET ATOR FOR NEED <br /> LOCAL REQUIREMENTS <br /> FS �2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.