August 11,2023 <br /> San Joaquin Environmental Health-Hazmat <br /> Response to Comments of 6H13123 <br /> Per your request,this is the list Elena Manzo sent on 6/13/23. <br /> Since we are not the responsible party for these documents all the sheets have new title blocks. So <br /> all are attached. There are a few sheets where there are no changes. It is easy to spot a change as <br /> any change shows up bolder than the original. Sheet T&L6, El, E2, E3 had no changes other than <br /> the title block. <br /> 1. Provide updated service requests and permit applications to remove MVP, this should also <br /> include correct billing information and a fire permit number (provide a front page of the approved <br /> permit). All appropriate checkboxes and monitoring details should be indicated. <br /> We have not chosen a contractor yet. When we have we will update all these forms <br /> 2. Provide ELD workplan This is done by the contractor <br /> 3. Provide tank charts and overfill calculations See attached sheets <br /> 4. Sheet T&L1 lists 24k/6k tank and Sheet CO lists 20K/6k tank. The cover sheet is new, revised the <br /> scope of work. <br /> 5. Identify smart sensor locations on T&L1 sheet See sheet T&L1. <br /> 6. Page T&L2 indicates that if people are entering the excavation OSHA notification and a <br /> permit is required. Please submit this permit copy for the tank set and anchoring work- if not <br /> available yet, this must be submitted before scheduling tank set inspection. Same page detail C6- <br /> "1/4"fuel hose capped"—clarify if this is a fuel hose or a vacuum hose. Also on C6 detail "opening <br /> through primary wall"—no openings through the primary wall are allowed. Contractor will do this. <br /> 7. Identify the means to check communication for vacuum monitoring on piping secondary <br /> containment on page T&L2, UDC detail. Seedetails <br /> 8.T&L3, detail 5, and T&L4- sump liquid sensor is not shown at the lowest sump point Revised <br /> location <br /> 9. Provide cut sheets for tank sumps and penetrations (including electrical) Oand for all UDC <br /> and Vent sump penetrations, leak detectors, overfill. See attached <br /> 10.The provided parts order list shows 2 tanks with 2 compartments each, plans show <br /> twocompartment Revised parts list tanks, 100, 103 see T&L7 and 7.1 <br /> and three-compartment tanks, clarify and send in the corrected parts order list <br /> 11. Provide installer/tester certifications for FE Petro and Flex-ing (Fireflex) When we have a <br /> contractor <br /> 12. Provide B-20 compatibility information for all components in contact with B-20 See attached <br /> sheets <br /> 13.T&L4, the 6K/24K fill sump on 24K tank chaise penetration is not located at sump wall but is <br /> K12 Architects,Inc. 3090 Fite Circle,Suite 104, Sacramento,CA. 95827 Phone: (916)455-6500 Fax:(916)455-8100 <br />