My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
4607
>
2300 - Underground Storage Tank Program
>
PR2500817
>
INSTALL_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2026 12:59:00 PM
Creation date
7/18/2024 2:58:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2024
RECORD_ID
PR2500817
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0004996
FACILITY_NAME
AIRPORT PETROLEUM, LLC
STREET_NUMBER
4607
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
Stockton
Zip
95206
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
4607 S AIRPORT WAY Stockton 95206
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
784
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r�j ; <br /> A r--=- <br /> located inside the sump. Also, 6K super tank fill sump has an unlabeled penetration and pipe with <br /> what appears to be an electrical connection that terminates at the bottom of the sump. Revised <br /> details <br /> 14. T&I-4, details A3 and A4 don't show chaise lines Added line. <br /> 15. T&I-6, Need vacuum communication details. Added to details <br /> 16. Bravo deflector plates are proposed on T&I-6, submit bravo cut sheet and installation <br /> information and indicate on plans how they will be installed. Revised to tank manufacturer. <br /> 17. No chaise piping is shown to 20K diesel fill sump for vent piping run to vent transition sump. <br /> No chaise piping is shown for this tank on T&I-1, update all necessary sheets as well as vacuum zone <br /> details, piping length and volumes. See T&I-1 and tanks sections. <br /> 18. It's unclear if the master/satellite piping is VPH-monitored double wall piping. Provide a <br /> revision that illustrates, that master/satellite dispenser piping is double wall and VPH monitored. <br /> No monitoring details or vacuum hose connections are shown inside the UDCs x-sections for <br /> master/satellite dispensers. Update vacuum zones to include pipe lengths and volume details. <br /> Revised the details to show this. YES THEY ARE MONITORED <br /> 19. Not all parts on the list parts and their diamond reference numbers on each respective plan <br /> sheet match across the plans. For example, part 402 listed multiple times on T&I-2 and appears to <br /> point to a Bravo sump penetration, is listed as Fire Flex on the parts list located on page T&I-7.To <br /> avoid any plan review delays, ensure that all parts lists are accurate on the future submittals (pages <br /> T&I-7 and T&I-7.1) and reference accurate parts on all the plan sheets. Done <br /> 20. Please confirm that no ball floats are proposed on these plans. Effective October 1, 2018, <br /> flow restrictors are prohibited from being installed to repair or <br /> replace overfill prevention equipment. There are no ball floats, added note on tanks sections. <br /> Stacy I;Uvera <br /> Lead Sr.Registered Environmental Health Specialist <br /> San Joaquin County Environmental Health Department <br /> 1868 E.Hazelton Ave., Stockton,CA 95205 <br /> phone(2og)616-3043 <br /> JaX(209)468-3433 <br /> *Test notifications and test results should be sent to the general USTernail: ust@sjgov.org* <br /> *NOTE* I will be out of office every other Friday. If you are unable to reach me on those days and need to speak to <br /> someone immediately, please call(209)468-3420 or email our UST email address. <br /> July 7,211 August 4, 18 1 September 1, 15, 29 1 October 13, 27 <br /> EHD will be closed for the holidays on: <br /> September 4 1 November 10, 23,24 1 December 25 1 January 1, 15 <br /> K12 Architects,Inc. 3090 Fite Circle,Suite 104, Sacramento,CA. 95827 Phone: (916)455-6500 Fax:(916)455-8100 <br />
The URL can be used to link to this page
Your browser does not support the video tag.