2800
>
2800 - Aboveground Petroleum Storage Program
>
PR0516358
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 2:13:35 PM
Creation date
7/30/2024 1:59:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0516358
PE
2832 - AST FAC 10 K - </=100 K GAL CUMULATIVE
FACILITY_ID
FA0003774
FACILITY_NAME
VALLEY FARMS TRANSPORT
STREET_NUMBER
2800
STREET_NAME
TURNPIKE
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
16528007
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
2800 TURNPIKE RD STOCKTON 95206
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />CP22 - AST Non-Qualified Inspection Report <br />Date: <br />May 21, 2024 <br /> Facility Address: <br /> 2800 TURNPIKE RD, STOCKTON <br /> Facility Name: <br /> VALLEY FARMS TRANSPORT <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />Drainage Logs found in Attachment B and kept on site with the SPCC Plan for a minimum of three years . No drainage <br />activity records were observed on site at the time of inspection. <br />REGULATION GUIDANCE: (c)(3)(iv) Keep adequate records of such events, for example, any records required under <br />permits issued in accordance with §§ 122.41(j)(2) and 122.41(m)(3) of this chapter. <br />CORRECTIVE ACTION: Immediately begin maintaining adequate records (or NPDES permit records) of drainage from <br />diked areas. Submit proof of correction to the EHD. <br />This is (Minor) Violation. <br />Code of Fed Regulations 112.7(e), 112.8(c)(6) 4010021 - Written Inspection/testing procedures kept, inspection/testing <br />records signed, kept for 3 years. <br />OBSERVATION: The facility failed to keep written records of inspections and tests, including integrity tests and <br />periodic inspections for at least three years. <br />-The SPCC Plan states that monthly and annual inspection should be performed and documented using the SP-001 <br />checklists provided in Attachment B and kept on site with the SPCC Plan for at least five years . No copies of <br />inspection and testing records were observed on site at the time of inspection. <br />REGULATION GUIDANCE: 112.7(e), Conduct inspections and tests required by this part in accordance with written <br />procedures that you or the certifying engineer develop for the facility. You must keep these written procedures and a <br />record of the inspections and tests, signed by the appropriate supervisor or inspector, with the SPCC Plan for a period <br />of three years. Records of inspections and tests kept under usual and customary business practices will suffice for <br />purposes of this paragraph. 112.8(c)(6) Test or inspect each aboveground container for integrity on a regular schedule <br />and whenever you make material repairs. <br />CORRECTIVE ACTION: Inspections and tests must be conducted in accordance with the written procedures <br />developed in the Spill Prevention, Control, and Countermeasure (SPCC) Plan. Records of these inspections and tests <br />must be signed by the appropriate supervisor or inspector and kept on-site with the SPCC Plan for three years. <br />Immediately locate a copy of all inspection and testing records for the last three years, maintain them on-site, and <br />submit copies to the EHD. <br />This is (Class 2) Violation. <br /> 57 <br />Code of Fed Regulations 112.7(a)(1), 112.8(c)(8) 4010056 - SPCC adequately describes overfill prevention methods, <br />and devices/systems used for each container. <br />OBSERVATION: The SPCC Plan failed to adequately describe the overfill prevention methods, including a description <br />of the devices or systems in place for each container to prevent overfills. <br />-The plan states that liquid level sensing devices must be tested following the manufacturer's recommended <br />procedures as part of the annual inspection. <br />-No manufacturer guidelines were included in the SPCC Plan for the product level gauge utilized as an overfill <br />prevention method during filling activities for AST -1 (diesel fuel). <br />-No overfill prevention was discussed for AST -2, AST-3 or 55 gallon drums. <br />REGULATION GUIDANCE: 112.7 (a)(1) Include a discussion of your facility's conformance with the requirements listed <br />in this part [§112.7]. 112.8 (c)(8) Engineer or update each container installation in accordance with good engineering <br /> 59 <br />FA0003774 PR0516358 SC001 05/21/2024 <br />EHD Rev. 12/06/2021 CP22 - AST Non-Qualified OIRPage 10 of 12 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.