My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
345
>
2300 - Underground Storage Tank Program
>
PR0540987
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2026 3:11:44 PM
Creation date
7/30/2024 2:51:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0540987
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0023459
FACILITY_NAME
Flying J Travel Center Lathrop - 1017
STREET_NUMBER
345
Direction
E
STREET_NAME
ROTH
STREET_TYPE
RD
City
French Camp
Zip
95231
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\cfield
Supplemental fields
Site Address
345 Roth RD FRENCH CAMP 95231
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
110
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin Valley HEWHY AIR UVIN9 <br /> www.haill#hydirliving.gom <br /> AIR POLLUTION CONTROL DISTRICT Make low etwup 1hr Wen$i71. <br /> TP-201.1C/D <br /> Leak Rate of Drop Tube/Drain Valve Assembly and Leak Rate of Drop Tube Overfill Protection <br /> Devices and Spill Container Drain Valves Report Form <br /> Permit Number: N/A Test Company: Jones Covey Group, Inc. <br /> Site Name: Pilot 1017 Lathrop Technician: Keith Henderson <br /> Site Address: 345 Roth Rd. Certification Number Expiration Date <br /> City: Lathrop Zip: 95330 District: SJV-0242 3/31/2026 <br /> Date/Time of Test: 8/27/2024 @ 11:45am <br /> DROP TUBE DRAIN VALVE AND OVERFILL PROTECTION DEVICE PRESSURE INTERGITV TEST <br /> ❑ Straight Drop Tube ® Drop Tube with an Overfill Protection Device <br /> Pressure measuring device ® digital manometer mechanical gauge <br /> Calibration date for pressure measuring device(must be within 18o days of the test) 7/23/2024 <br /> Ending value for digital manometer drift test if applicable(must be o.oi in.w.c.or less) 0.00 <br /> Drop Tube Drain Valve Pressure Test: Drop Tube Overfill Device Pressure Test: "Corrected"Overfill Device Leak Rate <br /> Flow rate 80 ml/min Flow rate 200 mUmin <br /> Time to reach 2 in. Drain valve Final Time to reach 2 in. Overfill Final Overfill Minus Equals <br /> w.c. at 80 ml/min leak rate' pressure w.c. at 200 ml/min leak rate' pressure Device Drain Valve Corrected <br /> Leak Rate Leak Rate Leak Rate <br /> Tank Grade mins. ml/min in.w.c. mins. ml/min in. w.c. ml/min ml/min ml/min <br /> 1 87 15 Sec. Oml 2.03 4 Minutes 13 Sec. Oml 1.97 <br /> 2 91 10 Seconds Oml 2.02 4 Minutes 05 Sec. Oml 2.00 <br /> 3 <br /> 4 <br /> NOTES: 'A straight drop tube must be tested with a bladder in place and using a flow rate of 80 ml/min. <br /> 2The bladder section of TP-201.1D may be skipped if the entire drop tube passes with a leak rate below 80 ml/min. <br /> 3Leak rate=nitrogen flow rate needed to maintain a constant pressure(at least 2 in.w.c.)for 30 seconds. <br /> I declare, under penalty of perjury under the laws of the state of California that based on information and belief formed after reasonable inquiry, the <br /> statements and information provided in this document are true, accurate, and complete. <br /> Signature of Technician: Date: 8/27/2024 <br /> Ver. 1.3—08.07.09 <br />
The URL can be used to link to this page
Your browser does not support the video tag.