Laserfiche WebLink
A dOAQU1N Environmental Health Department <br /> CQLJIVTY AMENDED <br /> 5/22/2024 <br /> CP22 - AST Non-Qualified Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ReConserve of California-Stockton, Inc 704 ZEPHYR ST, STOCKTON May 21 2024 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> discharges, or accumulation of oil inside diked areas. <br /> REGULATION GUIDANCE: REGULATION GUIDANCE: 112.8(c)(6)Test or inspect each aboveground container for <br /> integrity on a regular schedule and whenever you make material repairs. <br /> CORRECTIVE ACTION: Immediately conduct the necessary integrity testing and inspection on the two 250 gal tank, <br /> one 350 gal tank, and one 12,000 gal tank based on industry standards, on a regular schedule, after making material <br /> repairs, using non-destructive testing, inspecting each container's supports,foundations, and outside for signs of <br /> deterioration, discharges,or accumulation of oil inside diked areas. Maintain testing and inspection records. Submit a <br /> copy of the test/inspection results to the EHD. <br /> This is (Class 2)Violation. <br /> 57 Code of Fed Regulations 112.7(e), 112.8(c)(6)4010021 -Written Inspection/testing procedures kept, inspection/testing <br /> records signed, kept for 3 years. <br /> OBSERVATION:The facility failed to keep written procedures and records of inspections and tests, including integrity <br /> tests,for at least three years. Copies of inspection and testing records for 2022, 2023, 2024 were not found on site. <br /> REGULATION GUIDANCE: 112.7(e), Conduct inspections and tests required by this part in accordance with written <br /> procedures that you or the certifying engineer develop for the facility. You must keep these written procedures and a <br /> record of the inspections and tests, signed by the appropriate supervisor or inspector,with the SPCC Plan for a period <br /> of three years. Records of inspections and tests kept under usual and customary business practices will suffice for <br /> purposes of this paragraph.11 2.8(c)(6)Test or inspect each aboveground container for integrity on a regular schedule <br /> and whenever you make material repairs. <br /> CORRECTIVE ACTION: Inspections and tests must be conducted in accordance with the written procedures <br /> developed in the Spill Prevention, Control, and Countermeasure(SPCC)Plan. Records of these inspections and tests <br /> must be signed by the appropriate supervisor or inspector and kept on-site with the SPCC Plan for three years. <br /> Immediately locate a copy of all inspection and testing records for the last three years, maintain them on-site, and <br /> submit copies to the EHD. <br /> This is (Class 2)Violation. <br /> Overall Inspection Comments: <br /> An inspection checklist was provided to the facility operator on the day of inspection. A complete report was <br /> finished on 5/22/2024 and replaces the initial checklist. Complete and submit a copy of the Return to Compliance <br /> Certification form to the EHD with a statement documenting the corrective actions that have been or will be taken <br /> for each violation, and any supporting paperwork, within 30 days of receiving the complete inspection report. <br /> To minimize person to person contact EHD is choosing to write the name of person receiving the report instead of <br /> having them sign. Starting September 1, 2018, all in-office CERS help will be provided at the EHD hourly rate <br /> ($162). To schedule an appointment, please call (209)468-3420. <br /> The following was observed during this inspection: <br /> -One 12,000 gallon diesel tank <br /> FA0015010 PR0540778 SCO01 05/21/2024 <br /> EHD Rev.12/06/2021 Page 8 of 9 CP22-AST Non-Qualified OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />