Laserfiche WebLink
Environmental Health Department <br />Telephone: (626) 575-3070 Owner/Operator: GOLDEN OPPORTUNITY INVESTMENTS LP <br />Inspection Type: Routine Inspection <br />Address: 302 W BENJAMIN HOLT DR, STOCKTON 95207 <br />Date: 06/03/2024Name of Facility:VILLAGE NORTH APARTMENTS <br />Reinspection on or after: 06/04/2024 <br />Swimming Pool Official Inspection Report <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public <br />health and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />VIOLATIONS AND CORRECTIVE ACTIONS <br /> #1 Pool Gates <br />OBSERVATIONS: The pool entrance gate does not have a latch. Install a latch so that pool gate is self-closing and latches. <br />Close pool area until the corrections are made and verified by this department. <br />CALCODE DESCRIPTION: Gates and doors leading into the pool area shall be equipped with self-closing self-latching devices. <br />Self-latching devices shall be designed to keep the gate or door securely closed. Gates and doors shall open outward from the pool <br />area except where otherwise prohibited by law. (CBC 3119B) Pool operator shall keep gates and doors leading into the pool area well <br />maintained. (CCR 65535) <br />This is (Major) Violation. <br />MAJOR <br /> #2 Pool Enclosure <br />OBSERVATIONS: One of the rails near the entrance is missing leaving a large gap. Repair fence so that there are no gaps <br />greater than 4 inches. Correct today. Close pool area until the corrections are made and verified by this department. <br />(REPEAT) <br />CALCODE DESCRIPTION: Pool area shall be enclosed by one or more of the following: a fence, portion of a building, wall, or other <br />approved durable enclosure. Pool enclosure shall be constructed over a hard permanent material equivalent to concrete and shall be <br />installed no more than 2 inches above the finished grade. Holes, gaps, or openings in the enclosure shall not allow the passage of a <br />4-inch diameter sphere. Doors, openable windows, or gates of living quarters shall not be permitted as part of the pool enclosure. <br />(CBC 3119B) Pool operator shall keep the pool enclosure well maintained. (CCR 65535) Pool enclosure shall have a minimum <br />effective perpendicular height of 5 feet and shall be constructed so that it cannot be climbed by small children. Horizontal members <br />shall be spaced at least 48 inches apart. No planters or other climbable structures shall be permitted within 5 feet of the pool <br />enclosure or within a 5-foot arc. Chain link openings shall not be larger than 1 3/4 inches when measured horizontally. Pool <br />enclosures with a height of 4 or more feet are allowed if the enclosure was constructed prior to July 1994. (CBC 3119B) <br />This is (Major) Violation. <br />MAJOR <br /> #10 Disinfectant Residual <br />OBSERVATIONS: Free chlorine is below 2 ppm. Adjust to 2 ppm to 10 ppm. Close pool until the corrections are made and <br />verified by this department. <br />CALCODE DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall <br />maintain the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with <br />cyanuric acid or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to <br />10.0 ppm free chlorine or 4.0 ppm bromine. (CCR 65529) <br />This is (Major) Violation. <br />MAJOR <br />Page 1 of 3EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br /> PR0360486 06/03/2024 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD