D <br />I. SHOWERS, DRESSING FACILITIES, AND TOILETS (3115B) <br />1. One bather/15 square feet of pool surface. Divide factor by 2 to determine sex distribution. <br /> <br />Ap 2. One shower/50 bathers. EXCEPTION: Showers and dressing facilities not required if <br />available in adjacent living quarters, within 300 feet of pool. <br />6r_ 3. One toilet/60 women; one toilet and urinal/75 men; one lavatory/80 bathers. EXCEPTION: <br />Restrooms not required if they are available within 300 feet of pool at living quarters or <br /> <br />4i <br />adjacent building. <br />Floors sloped not less than 1/4 inch per foot to drains or other approved surface disposals. <br />l 4651. Shower and lay temperature control which limits temperature to 110° F. <br />Hot and cold water to showers and lavatories. <br />J. DRINKING FOUNTAINS (3116B) <br />1. Guarded angle jet drinking fountains required unless water is available at adjacent living <br />quarters or adjacent building. Number of fountains based upon one bather/15 square feet <br />and computed at 1 fountain/250 bathers plus an additional fountain for each additional 200 <br />bathers. <br />K. HOSE BIBBS (3117B) <br />1. Provided at each pool and protected against backflow, within 75 feet of all deck areas. <br />L. FENCING AND GATES (3118B, Figures 31B-4 and 31B-5) <br />; 1. Provided at each pool and spa pool, enclosed by 5 feet minimum height fence, building, or <br />enclosure. NOTE: Doors, openable windows, or gates of living quarters or associated <br />private premises shall not be permitted as part of the pool enclosure. <br />Openings, holes or gaps in the enclosure, doors and/or gates shall not allow the passage of <br />a 4 inch diameter sphere. The bottom of the enclosure shall be within 2 inches of the <br />finished grade. <br />Horizontal members shall be spaced at least 48 inches apart. Horizontal and diagonal <br />member designs, which might serve as a ladder for small children, are prohibited. <br />Chain link openings are not greater than 1 1/4 inches measured horizontally. <br /> 5. Gates and doors shall be equipped with self-closing and self-latching devices located at least <br />3 1/2 feet above the deck or walkway. EXCEPTION: Doors leading from areas of hotels and <br />motels, as defined in the Business and Professions Code Section 255Q3.16(b), which are <br />open to the general public, e.g., restaurants, lobbies, bars, meeting rooms, and retail shops <br />need not be self-latching. <br />The enclosure shall be designed and constructed so that all persons will be required to pass <br />through common pool enclosure gates or doors in order to gain access to the pool area. All <br />gates and doors exiting the pool area shall open into a public area or walkway accessible by <br />all patrons of the pool. <br />Gates and doors shall open outward away from the pool except ,'Nhere otherwise prohibited <br />by law.