Laserfiche WebLink
M. SIGNS (3119B, 65539) and Safety Equipment (3108B, 65529, 85539) (680-13, 3114B) <br />Occupant Load — bather/20 square feet of water surface area except SPA, 1 bather/10 <br />square feet. EXCEPTION: Wading pools exempt. <br />"No Diving Allowed" sign for pools less that six feet deep. <br />Gas Chlorine warning sign. <br />SPA warning sign. <br />Artificial Respiration Procedures sign. <br />"Warning No Lifeguard" sign. <br />Emergency Phone Number sign. <br />Rescue pole with body hook. <br />Life ring with rope. <br />Safety rope with buoys (if slope break). <br /> 11. Test kit. <br />Emergency Shut-Off Switch sign for spa. <br />"No Use of Pool Allowed After Dark" (pools without lights). <br />Gas Chlorination Equipment Room Switch sign, "Turn On Before Entering." <br />N. INDOOR VENTILATION (3120B) <br />{10‘ 1. Indoor pools shall be adequately ventilated. <br />FOUNDATIONS FOR POOL EQUIPMENT (3121B) <br /> 1. Equipment to be mounted on concrete pad and sloped at least 1/4 inch per foot to drain Or <br />other approved surface disposal. <br />P. GAS CHLORINE ROOM (3122B) <br />Room not located below ground level. <br />Entry door shall open to the exterior of the building and shall not open directly toward the <br />pool or pool deck. <br />Mechanical exhaust which produces at least 60 air changes per hour and is vented to <br />outside air. Discharge located at least 10 feet from windows or adjacent building. <br />Fresh air intake within 6 inches of ceiling. <br />Spray bottle of commercial strength ammonia. <br />Q. SHARED RECIRCULATION (3123B.1) <br />1. SPA: Two spa pools permitted to share the same recirculation and treatment 'system <br />provided that the flow and sanitization are individually metered and adjustable. <br />6