Laserfiche WebLink
'ft <br /> <br />Wl/r x11% <br />. <br />'77X' <br />= 11315V1d3tid t <br />Y. Signs and Safety Equipment (2-9025,722-65539 and 65547) <br />Pool surface area sq.ft. divided by 20 equals (Occupant Load, 4 in. letters). <br />"No Diving Allowed" signs (2 or more) in 4 in. letters I1or pools less than 6 ft. deep. <br />"No Lifeguard" warning in 4 in. letters and children under 14 notice. <br />Artificial Respiration illustration and notice to begin artificial respiration if needed. <br />Emergency phone numbers for nearest ambulance, fire, and police. <br />"No use allowed after dark" sign in 4 in. letters if no pool Lighting. <br />"Danger: Gaseous Oxidizer-Chlorine" sign 4 in. letters. <br />Emergency evacuation procedure if gas chlorine is used. <br />Body hook bolted to a light, strong, non-telescoping 12 ft. pole. <br />Life ring, 17 in. die., with 3/16 in. line to span width of pool. <br />First aid kit. <br />All items on page completed <br />ii 1 <br />=WM.= <br />=MM. <br />=MM. CraZIIM I=Orki-W <br />=VA= RIANGIVA <br />SAN JOAQUIN PUBLIC HEALTH SERVICES ENVIRONMENTAL HEALTH SWIMMING POOL PROGRAM <br />1601 East Hazelton Ave., P.O. Box 2009, Stockton, CA 95201, (209) 468-3420 <br />SA. Spa Construction (2-9003 <br />1. Plans for the spa shall be drawn to a scale of 1 in. to 1 ft. <br />Finish color may be white or light pastel color. A contrasting color is required on edges <br />of bench and steps. <br />Max. water depth over bench is 24 in. <br />Max surface area 250 sq.ft.; max. depth 4 ft. <br />SC. Inlets (2-9042) <br />1. Spa may have 1 inlet and it need not be 18 in. below water level. <br />SF. Water Supply (2-9035) <br />1. Spas are exempt from having permanently installed line. <br />SG. Spa Bottom Drain (2-9042) <br />Duplicate drains for both the recirculation and aeration/jet systems or single drains <br />with safety covers for both systems. <br />Si. Spa Steps (2-9015) <br />Tread min. 12 in. <br />One handrail for 9 in. max. riser, 2 handrails for up to 12 in. max. riser. <br />Handrail over steps and max. of 12 in. from plane of bottom riser. <br />SK. Handholds (2-9018) <br />3. Other types of handholds permitted at spa. <br />SL. Permanent Markings (2-9014) <br />2. Min. of 2 depth markers indicating max. depth. <br />SW. Decks (2-9018) <br />1. Min. 4 ft. deck around 50X of spa and at spa steps. Min. 6 ft. deck separation between pool <br />and spa. No partial deck. <br />5. Unpaved areas (landscape planters, etc.) must be min. 4 ft. away from spa. <br />SS. Spa Equipment (2-9031) <br />1. Two spas may share systems if flow and chlorination rates adjustable for each spa. <br />SY. Signs and Safety Equipment (2-9025 and 722-65539) <br />1. Spa surface area sq.ft. divided by 10 equals (occupant load)(max. of 25). Sign <br />requires 4 in. letters. <br />3. "No Life Guard" sign is not required. <br />Body hook is not required. <br />Life ring is not required. <br />12. Spa "CAUTIOH" sign is required - posted near entrance to spa. <br />SZ. Spa Pool Special Requirements (2-9043 and 3-680-13) <br />Aeration/jet system separate from filtration system and not connected to any pool. <br />Emergency shut-off switch for filter and jet pumps, labelled and adjacent to spa. Ten ft. <br />separation from jet timer. <br />All items on page completed <br />SPA POOL SUI10LEMENT(V) SWIMMING <br />Re77›\ <br />POOL PLAN CHECK SHEETS