Laserfiche WebLink
10,000 GAL DIESEL10,000 GAL. 91 UNLEADED4" TO 6"DEFLECTOR PLATE DEFLECTOR PLATE4" TO 6"CONCRETE SLAB SHALL EXTEND <br />A MIN OF 2'-0" BEYOND THE <br />ENDS AND SIDES OF TANKS, <br />SEE SITE PLAN <br />DROP TUBE WITH <br />OVERFILL VALVE <br />SET AT 95% <br />MAG PLUS <br />LIQUID LEVEL <br />PROBE <br />20 <br />FS4.1 <br />8 <br />FS4.1 6 <br />FS4.1 <br />12 <br />FS4.1 <br />8 <br />FS5.0 <br />6 <br />FS5.0 <br />12 <br />FS4.1 <br />18 <br />FS4.1 <br />20,000 GAL. 87 UNLEADEDVACUUM SENSOR <br />DBL WALL PIPE TO FILL <br />SUMP TO BRING VACUUM <br />LINE TO FILL SUMP FOR <br />VENT AND VAPOR LINES <br />TO TLS <br />TO VAPOR LINE INTERSTITIAL <br />TO DISPENSERS, ZONE 1 <br />TO VENT LINE INTERSTITIAL <br />TO VENT SUMP, ZONE 1 <br />PRODUCT LINE INTERSTITIAL <br />VACUUM LINE <br />TO DISPENSERS, ZONE 1. <br />PRODUCT LINE INTERSTITIAL <br />VACUUM LINE TO <br />DISPENSERS, ZONE 2. <br />DBL WALL PIPE TO <br />FILL SUMP TO BRING <br />VACUUM LINE TO FILL <br />SUMP FOR VENT LINE <br />VENT LINE INTERSTITIAL <br />VACUUM LINE <br />TO VENT SUMP, ZONE 2. <br />PRODUCT LINE INTERSTITIAL <br />VACUUM LINE TO <br />DISPENSERS, ZONE 3. <br />VENT LINE INTERSTITIAL <br />VACUUM LINE TO VENT +CROSSOVER <br />SUMP, ZONE 3. <br />VACUUM SENSOR <br />TEST PORT WITH TEST HOSE AND <br />CONNECTION CAP <br />VACUUM SENSOR <br />DBL WALL PIPE TO <br />FILL SUMP TO BRING <br />VACUUM LINE TO FILL <br />SUMP FOR VENT LINE <br />TEST PORT WITH TEST HOSE AND <br />CONNECTION CAP <br />DROP TUBE WITH <br />OVERFILL VALVE <br />SET AT 95% <br />MAG PLUS <br />LIQUID LEVEL <br />PROBE <br />DROP TUBE WITH <br />OVERFILL VALVE <br />SET AT 95% <br />MAG PLUS <br />LIQUID LEVEL <br />PROBE <br />TEST PORT WITH TEST HOSE <br />AND CONNECTION CAP <br />TEST PORT WITH TEST HOSE <br />AND CONNECTION CAP <br />TEST PORT WITH TEST HOSE <br />AND CONNECTION CAP <br />21 <br />75 <br />80 <br />21 <br />75 <br />81 <br />BRINE INTERSTITIAL <br />SENSOR <br />21 <br />BRINE INTERSTITIAL <br />SENSOR 79 <br />BRINE INTERSTITIAL <br />SENSOR 79 <br />BRINE INTERSTITIAL <br />SENSOR 79 <br />BRINE INTERSTITIAL <br />SENSOR 79 <br />79 <br />4" CONDUIT, <br />SCHEDULE 40 <br />81 <br />80 8180 <br />SEE SHEET FS2.0 FOR EQUIPMENT LIST <br />NOTE: <br />75 <br />4'-0"4'-0" <br />16'-2"8"PEA GRAVEL <br />PAN SENSOR <br />TO WITHIN 1" OF LOWEST POINT <br />79 <br />PAN SENSOR <br />79 <br />BRINE INTERSTITIAL <br />SENSOR 78 <br />BRINE INTERSTITIAL <br />SENSOR 78 <br />PAN SENSOR <br />79 <br />PAN SENSOR <br />79 <br />PAN SENSOR <br />79 <br />PAN SENSOR <br />79 <br />79A 79A <br />79A <br />SHEET NUMBER: <br />SHEET CONTENTS: <br />PROJECT NUMBER:PROJECT DATE: <br />CONSULTANTS: <br />Sacramento, CA 95827 <br />PH:(916) 455-6500 FAX:(916) 455-8100 <br />3090 Fite Circle, #104 <br />REVISIONS: <br />20-007 08-14-2020 <br />K12 Architects, Inc <br />DEVELOPER: <br />CONTRACTOR: <br />PROJECT: <br />Fast N <br />Easy <br />RIVER <br />ISLANDS <br /> 16460 GOLDEN VALLEY <br />PARKWAY <br />Lathrop, California 95330 <br />1 <br />Muhammad Bilal <br />10445 Chantel Lane <br />Stockton, CA 95212 <br />CONVENIENCE STORE AND <br />FUELING STATION <br />Parcel 1 <br />BUILDING DEPT. COMMENTS 10/4/21 <br />2 PLANNING DEPT REV 10/14/21 <br />3 BUILDING DEPT. COMMENTS 06/22/22 <br />3-25-2022 <br />4 BUILDING DEPT. COMMENTS 09/21/22 <br />5 FIRE DEPT. COMMENTS 10/19/22 <br />6 EHD-HAZMAT 12/12/22 <br />7 EHD-HAZMAT 02/03/23 <br />PROFESSIONAL SEALS: <br />8 ELECT MSB 06/28/23 <br />9 OWNER CHANGE 08/02/23 <br />10 WALK-IN COOLER DETAILS 10/13/23 <br />11 VEEDER-ROOT TLS-450 05/17/24 <br />18 <br />20 87 UNLEADED FUEL TANK MONITORING <br />1/2" = 1'-0"SCALE: <br />DIESEL / 91 UNLEADED FUEL TANK MONITORING <br />1/2" = 1'-0"SCALE: <br />FS7.0 <br />MONITORING <br />SYSTEM <br />MONITORING NOTES <br />ALL SENSORS TO BE CONNECTED TO THE TLS 350 <br />THE SYSTEM IS COMPRISED OF VACUUM SENSORS, LIQUID SENSORS AND HYDROSTATIC <br />SENSORS. <br />THE FOLLOWING SENSOR LOCATIONS SHALL BE PROGRAMMED FOR COMPLETE SYSTEM <br />SHUT DOWN: <br /> ELECTRONIC LINE LEAK DETECTOR (PLLD) <br /> LIQUID DETECTION IN PRODUCT PIPING <br /> LIQUID SUMP SENSORS <br />THE FOLLOWING SENSOR LOCATIONS SHALL SET OFF AN AUDIBLE/VISUAL ALARM <br /> INTERSTITIAL HYDROSTATIC AND VACUUM SENSORS <br /> OVERFLOW PROBE <br /> LOW/HIGH PRODUCT SENSORS <br /> VAPOR PRESSURE SENSORS <br /> VAPOR FLOW METER <br />VACUUM MONITORING ZONES <br />ZONE 1: REGULAR TANK <br /> 3 INPUT VACUUM SENSOR <br /> PRODUCT LINE <br /> VENT LINE <br /> VAPOR LINE <br /> CROSS OVER PIPE <br />ZONE 2: PREMIUM TANK <br /> 3 INPUT VACUUM SENSOR <br /> PRODUCT LINE <br /> VENT LINE <br /> CROSS OVER PIPE <br />ZONE 3: DIESEL TANK <br /> 3 INPUT VACUUM SENSOR <br /> PRODUCT LINE <br /> VENT LINE <br />CROSS OVER PIPE <br />ZONE 4: BIO-20 <br /> 3 INPUT VACUUM SENSOR <br /> PRODUCT LINE <br /> VENT LINE <br /> CROSS OVER PIPE <br />ZONE 5: E-85 <br /> 3 INPUT VACUUM SNESOR <br /> PRODUCT LINE <br /> VENT LINE <br /> CROSS OVER PIPE <br />1 1/2" FLEX CONNECTORS <br />91 GAS ZONE 2 <br />87 GAS ZONE 1 <br />VAPOR ZONE 1 <br />ELECTRICAL IS PROVIDED <br />TO THE DISPENSER BY AN <br />OFFSET IN THE SUMP. <br />DISPENSER SUMP <br />DOUBLE WALL <br />SUMP LIQUID SENSOR <br />PLACED AT BOTTOM OF SUMP <br />74 <br />DIESEL ZONE 3 <br />78 <br />SUMP DBL WALL, <br />BRINE SENSOR 46 <br />2" FLEX CONNECTOR <br />49 <br />TEST PORT TYP <br />BRAVO FILL PORT <br />BRAVO TEST PORT WITH TEST <br />HOSE AND CONNECTION CAP <br />SCALE:3/4" = 1'-0" <br />SUMP MONITORING1 <br />SEE DETAIL 20/FS4 FOR SECTION <br />VENT SUMP SIMILAR <br />VACUUM SENSOR MONITORING <br />ZONES <br />ZONE 1 - 87 - UNLEADED <br />ZONE 1 - VAPOR <br />ZONE 2 - 91 UNLEADED <br />ZONE 2- VENT + CROSSOVER <br />ZONE 4 - BIO-20 VENT <br />+CROSSOVER <br />ZONE 5 - E-85 <br />1 <br />1 <br />2 <br />2 <br />4 <br />5 <br />SS MODULE <br />NUMBER <br />CHANNEL <br />NUMBER <br />1 <br />2 <br />1 <br />2 <br />2 <br />1 <br />LENGTH OF <br /> ZONE <br />333 <br />336 <br />362 <br />65 <br />77 <br />111 <br />ZONE 5 - E-85 VENT+CROSSOVER 5 2 58 <br />ZONE 4 - BIO-20 4 1 134 <br />ZONE 3 - VENT+CROSSOVER 3 2 44 <br />ZONE 3 - AUTO DIESEL 3 1 242 <br />ZONE 1 - VENT+CROSSOVER 1 3 61 <br />7 <br />77 <br />7 <br />7 <br />7 <br />7 <br />7 <br />11 11 <br />11