Laserfiche WebLink
9 <br /> iota GRs <br /> Final ELD Test Project Worksheet <br /> Final Test Date: 1/27/2026 IOTA Technicians: Adam Momejano <br /> to Information CGRS Project No: 61.29632 Installation Contractor Information <br /> Facility: Tracy Triangle Fueling Customer Name: Able Maintenance <br /> Address: W Larch Rd&N Tracy BIVd Address: 3224 Regional Parkway <br /> City,Stale,Zip: Tracy,CA 96304 City,State,Zip: Santa Rosa,CA 95403 <br /> County: San Joaquin Contact: Shea Fuller <br /> CUPA Email: ust@sjgov.org Phone/Email: 707569.4791/Shea.Fuller@ablemalntenance.com <br /> TANKS <br /> Tank No. Ca aci al. Product T e Manufacturer Brine Test Result <br /> Tank 24,000 87 Octane DW FIBERGLASS XERXES YES PASS <br /> Tank 15,000 91 Octane DW FIBERGLASS XERXES YES PASS <br /> Tank 15,000 Diesel DW FIBERGLASS XERXES YES PASS <br /> Tank 6,000 E85 DW FIBERGLASS XERXES YES PASS <br /> 1101-- COMPONENTS IN CONTAINMENT <br /> Tank Top Sums Diameter In. Depth In. Volume al. Description Test Result <br /> Si 48 62 485.68 87 TS PASS <br /> S2 42 62 371.85 87 FS PASS <br /> S3 48 62 485.68 91 TS PASS <br /> S4 42 62 371.85 91 FS PASS <br /> S5 48 62 485.68 DSL TS PASS <br /> 9 <br /> 6 42 62 371.85 DSL FS PASS <br /> S7 48 62 485.68 E85 TS PASS <br /> S8 42 62 371.85 E85 FS PASS <br /> Junction Boxes with Tank Connection Description Test Result <br /> Sl Tank Probe and Turbine J-Box Open During Test PASS <br /> S3 Tank Probe and Turbine J-Box Open During Test PASS <br /> S5 Tank Probe and Turbine J-Box Open During Test PASS <br /> S7 Tank Probe and Turbine J-Box Open During Test PASS <br /> UDC. Length in. Width in. Depth in Volume al. Description Test Result <br /> UDG1 42 20 32 116.36 BRAVO PASS <br /> UDC2 42 20 32 116,36 BRAVO PASS <br /> UDC3 42 20 32 116.36 BRAVO PASS <br /> UDC4 42 20 32 116.36 BRAVO PASS <br /> Transition Sump Length in. Width in. De h in. Volume al. Description Test Result <br /> TS1 42 30 32 174.55 VENT BOX PASS <br /> PIPING <br /> Product Piping Manufacturer Type Size in. Length fL Test Result <br /> 87 PL NOV DW FIBERGLASS 2 275 PASS <br /> 91 PL NOV DW FIBERGLASS 2 270 PASS <br /> DSL PL NOV DW FIBERGLASS 2 150 PASS <br /> E85 PL NOV DW FIBERGLASS 2 150 PASS <br /> Vent Piping Manufacturer Type Size in. Length ft. Test Result <br /> 87 Vent NOV DW FIBERGLASS 2 65 PASS <br /> 91 Vent NOV DW FIBERGLASS 2 55 PASS <br /> DSL Vent NOV DW FIBERGLASS 2 65 PASS <br /> E85Vent NOV DW FIBERGLASS 2 85 PASS <br /> Va or Piping Manufacturer Type Size in. Length R Test Result <br /> VR NOV DW FIBERGLASS 3 32() PASS <br /> 111111111�Leak Logs/Repair <br /> 7 1/28/2026 �x 1775 1/27/2026 <br /> Rtrrkwkd�]' Data IOTA Tech Signature CA License No. Date <br />