COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MOSSDALE
>
444
>
2300 - Underground Storage Tank Program
>
PR0231692
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2026 8:29:16 AM
Creation date
1/2/2025 4:51:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231692
PE
2361 - UST FACILITY
FACILITY_ID
FA0000212
FACILITY_NAME
Mossdale Chevron
STREET_NUMBER
444
Direction
W
STREET_NAME
MOSSDALE
STREET_TYPE
RD
City
LATHROP
Zip
95330
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
444 W MOSSDALE RD LATHROP 95330
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
63
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J OAQ U N Environmental Health Department <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Mossdale Chevron 1444 W MOSSDALE RD, LATHROP TJune 25, 2025 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 55 CA Code of Regulations 2716(f) 2010004- Copies of DO inspections for last 12 months maintained, 36 months for <br /> those after 10/1/18 (TCR 12) <br /> OBSERVATION: Reports were not maintained on site for 36 months. Reports from June 2022 through December 2022 <br /> were not present on site. <br /> REGULATION GUIDANCE: Designated operator inspection reports prior to October 1, 2018 shall be retained on site for <br /> twelve months. Designated operator inspection reports on or after October 1, 2018 shall be retained on site for thirty-six <br /> months. <br /> CORRECTIVE ACTION: Locate and ensure that copies of the previous thirty-six months of designated operator <br /> inspection reports are maintained on site. Submit copies of the missing reports to the EHD. <br /> This is a (Minor)Violation. <br /> 56 CA Code of Regulations 2716(a-e) 2030013 - DO inspections completed at least every 30 days and meet all <br /> requirements (TCR 12) <br /> OBSERVATION 1: Designated operator reports were not signed within the required time frame. <br /> -Multiple designated operator reports were not signed and dated by the owner/operator <br /> REGULATORY GUIDANCE: Within 48 hours of the completion of the designated UST operator visual inspection, the <br /> designated operator shall sign and provide the owner or operator with a copy of the inspection report. Within 72 hours of <br /> being provided a signed copy of the report, the owner or operator shall provide a description of each corrective action <br /> taken or to be taken and shall sign and date the report, acknowledging the identified compliance issues. <br /> CORRECTIVE ACTION: Ensure all designated operator inspection reports are completed and signed within the required <br /> time frame in the future. <br /> OBSERVATION 2: The designated operator failed to check and note all required items on the visual inspection reports. <br /> The incorrect and missing information included the following: <br /> -Multiple reports only list"BZ Service Station Maintenance, Inc" but do not list the DO name in section 2 <br /> -The DO failed to record the date the report was provided to the owner in section 4 of the 10/2/24 report <br /> REGULATION GUIDANCE: During the visual inspection, the designated operator shall check that all required testing and <br /> maintenance for the UST system have been completed and shall check all required items on the report. <br /> CORRECTIVE ACTION: Ensure that designated operators performing visual inspections at this facility are including all of <br /> the required information on the reports. <br /> This is a Repeat(Class 2)Violation. <br /> EHD-CUPA Inspection Report IS02 Page 5 of 7 FA0000212 PR0231692 4519949 6/25/2025 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.