My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
420
>
2300 - Underground Storage Tank Program
>
PR0544259
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/27/2026 7:41:52 PM
Creation date
1/9/2025 7:49:30 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0544259
PE
2361 - UST FACILITY
FACILITY_ID
FA0024739
FACILITY_NAME
KWIK SERV LODI
STREET_NUMBER
420
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06202042
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
420 1 W KETTLEMAN LN LODI 95240
Suite #
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A dOAQU1N Environmental Health Department <br /> CQUNT AMENDED <br /> 1/16/2025 <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> KWIK SERV LODI 420 W KETTLEMAN LN LODI January 13 2025 <br /> 88 CA Code of Regulations 2060007-Primary and secondary containment designed and constructed to an engineering ❑OUT ❑R ❑COS <br /> 2631(b&d),2666(b&e) specification. <br /> 89 CA Health and Safety 2060008-Enhanced leak detection testing performed before the tank is placed in use ❑OUT ❑R ❑COS <br /> Code 25290.10) <br /> 90 CA Code of Regulations 2060029-SW piping has been upgraded to continuously monitored DW piping when replacement ❑OUT ❑R ❑COS <br /> 2666(b)(2) or repair needed <br /> 91 CA Health and Safety 2010-Administration/Documentation-General ❑OUT ❑R ❑COS <br /> Code 25291(e) <br /> 92 2015-Administrative/Documentation-General Local Ordinance ❑OUT ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 28 CA Code of Regulations 2638(a),26410)2030043- Leak detection equipment properly installed, calibrated,operated, <br /> and maintained (TCR 9d). <br /> OBSERVATION:The waste oil tank annular sensor, model number 301, is not properly installed. Per the service <br /> technician at the time of inspection, the annular liquid-filled space consists of water. Water is not one of the listed <br /> manufacturer-specified reservoir solutions for use with the sensor <br /> REGULATION GUIDANCE:All monitoring equipment shall be installed, calibrated, operated, and maintained in <br /> accordance with manufacturer's instructions, and certified for operability, proper operating condition, and proper <br /> calibration. <br /> CORRECTIVE ACTION: Immediately contact a properly licensed and certified contractor to ensure the annular sensor <br /> is installed per manufacturer specifications. Ensure that all leak detection equipment is properly programmed and <br /> maintained at all times. <br /> This is(Class 2)Violation. <br /> 52 CA Code of Regulations 2635(c)(1)2030036-Overfill prevention system has not been overridden and meets overfill <br /> requirements(TCR 9b). <br /> OBSERVATION:The liquid level sensor and monitoring panel used as the overfill prevention system is not an approved <br /> method of overfill for the Used Oil UST.The monitoring panel used for the overfill alarm was not visible and audible at <br /> the tank fill point.When triggering the alarm, the service technician on site during inspection was unable to hear if the <br /> alarm was triggered at the tank fill point. <br /> REGULATION GUIDANCE:All UST systems must be equipped with an approved,functional overfill prevention device <br /> at all times during delivery operations. <br /> LOCAL GUIDANCE 150-3: Overfill alarms must be clearly visible and audible to the transfer operator at the tank fill <br /> point. <br /> CORRECTIVE ACTION: Immediately discontinue deposition of petroleum into this tank until the component is <br /> replaced by a properly licensed, trained, and certified contractor under permit and inspection of the EHD. If the failed <br /> component can't be replaced immediately, there is a possibility that the used oil UST system may be red tagged to <br /> prevent inputs. <br /> This is(Class 2)Violation. <br /> 53 CA Health and Safety Code 25292.2; CCR 2711(a)(11)2010007-Submitted/maintained current Cert of Financial <br /> Responsibility/mech of financial assurance(TCR 11). <br /> FA0024739 PR0544259 SCO01 01/13/2025 <br /> EHD Rev.12/06/2021 Page 5 of 7 CP22-UST FULL OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.