A dOAQU1N Environmental Health Department <br /> CQUNTY AMENDED <br /> 7/28/2025 <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> AISLE 1 #2356 4219 E MORADA LN STOCKTON i Uly 08 2025 <br /> 87 CA Code of Regulations 2060021-Striker plate installed and positioned correctly. ❑OUT ❑R ❑COS <br /> 2631(c),2662(d) <br /> 88 CA Code of Regulations 2060007-Primary and secondary containment designed and constructed to an engineering ❑OUT ❑R ❑COS <br /> 2631(b&d),2666(b&e) specification. <br /> 89 CA Health and Safety 2060008-Enhanced leak detection testing performed before the tank is placed in use ❑OUT ❑R ❑COS <br /> Code 25290.10) <br /> 90 CA Code of Regulations 2060029-SW piping has been upgraded to continuously monitored DW piping when replacement ❑OUT ❑R ❑COS <br /> 2666(b)(2) or repair needed <br /> 91 CA Health and Safety 2010-Administration/Documentation-General ❑OUT ❑R ❑COS <br /> Code 25291(e) <br /> 92 2015-Administrative/Documentation-General Local Ordinance ❑OUT ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 28 CA Code of Regulations 2638(a), 26410)2030043- Leak detection equipment properly installed, calibrated, operated, <br /> and maintained (TCR 9d). <br /> OBSERVATION: During the inspection, interstitial fluid in the other UDCs was observed to be a consistent pink/red <br /> color. However,the fluid inside the brine reservoir of UDC 1-2 appeared opaque and contained yellow debris,which <br /> may indicate contamination or degradation of the monitoring fluid. Brine sensors should be installed in <br /> manufacturer-approved interstitial monitoring fluid. <br /> REGULATION GUIDANCE:All monitoring equipment shall be installed, calibrated, operated, and maintained in <br /> accordance with manufacturer's instructions, and certified for operability, proper operating condition, and proper <br /> calibration. Immediately contact a properly licensed and certified contractor to fix the brine issue. <br /> CORRECTIVE ACTION: Ensure that all leak detection equipment is properly programmed and maintained at all times. <br /> This is (Class 2)Violation. <br /> 35 CA Health and Safety Code 25290.1(e)2030065- Interstitial space of the UST is under constant VPH monitoring (TCR <br /> 9d). <br /> OBSERVATION: During the inspection, it was observed that the brine reservoir for the interstitial space of tank <br /> containing 87product was empty, indicating a potential monitoring failure for the secondary containment system. <br /> Although the sensor passed function testing, the absence of brine compromises the effectiveness of continuous leak <br /> detection. <br /> REGULATION GUIDANCE:Title 23, California Code of Regulations (CCR), section 2631(a)(2),which requires that <br /> interstitial monitoring systems be maintained in a manner that ensures proper leak detection functionality at all times. <br /> CORRECTIVE ACTION: Document the corrective action taken, including the date the brine was restored,the certified <br /> person performing the maintenance. Provide the certification and work order to EHD. <br /> This is a repeat violation (Class 2) Violation. <br /> 47 CA Health and Safety Code 25290.1(c3), 25290.2(c3)2030008-Secondary containment installed after July 1, 2003 is <br /> free of water. <br /> OBSERVATION:Water was found in the diesel STP, 91 STP, and 87 STP sumps. <br /> REGULATION GUIDANCE: Secondary containment shall be constructed to prevent any water intrusion into the <br /> system by precipitation, infiltration, or surface runoff. <br /> FA0016523 PR0524617 SCO01 07/08/2025 <br /> EHD Rev.12/06/2021 Page 5 of 7 CP22-UST FULL OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />