My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MICHAEL CANLIS
>
7000
>
2300 - Underground Storage Tank Program
>
PR0504967
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2026 1:50:58 PM
Creation date
1/30/2025 11:36:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0504967
PE
2361 - UST FACILITY
FACILITY_ID
FA0006440
FACILITY_NAME
SHERIFFS OPERATIONS CTR #2
STREET_NUMBER
7000
Direction
N
STREET_NAME
MICHAEL CANLIS
STREET_TYPE
BLVD
City
FRENCH CAMP
Zip
95231
APN
19305014
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
7000 N MICHAEL CANLIS BLVD FRENCH CAMP 95231
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN aOAQUIN Environmental Health Department <br /> COUNTY— <br /> Greatness grows here. <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SHERIFFS OPERATIONS CTR#2 17000 N MICHAEL CANLIS BLVD FRENCH CAMP I November 05 2025 <br /> 49 25290.1,25290.2, 25291 2030047-Secondary containment maintained tight and has been confirmed by ❑OUT ❑ R ❑ COS <br /> testing <br /> 50 2635,2637.1, 2665, 2712 2060020-Spill buckets meet requirements, have been tested as required, and ❑ OUT ❑ R ❑ COS <br /> records kept for 36 mths(TCR 9a) <br /> 51 25292.1(a) 2030035-UST system is operated to prevent unauthorized release, including spills ❑ OUT ❑ R ❑ COS <br /> and overfills <br /> 52 2635(c)(1) 2030036-Overfill prevention system has not been overridden and meets overfill ❑ OUT ❑ R ❑ COS <br /> requirements(TCR 9b) <br /> 53 25292.2; CCR 2711(a) 2010007-Submitted/maintained current Cert of Financial Responsibility/mech of ❑ OUT ❑ R ❑COS <br /> (11) financial assurance (TCR 11) <br /> 54 2631,2640.1, 2665, 2711 2030007-Documentation of compatibility for UST system components submitted ❑OUT ❑ R ❑COS <br /> and/or maintained. <br /> 55 2716(f) 2010004-Copies of DO inspections for last 12 months maintained, 36 months for ❑OUT ❑ R ❑COS <br /> those after 10/1/18(TCR 12) <br /> 56 2716(a-e) 2030013-DO inspections completed at least every 30 days and meet all ❑ OUT ❑ R ❑ COS <br /> requirements(TCR 12) <br /> 57 2715(c) 2030012-Initial and annual training provided to employees and at least one ❑ OUT ❑ R ❑ COS <br /> trained employee is present <br /> 58 2715(c)(3), 2715(c)(4) 2010015-Copies of Facility Employee Training Certificates maintained ❑ OUT ❑ R ❑ COS <br /> 59 2712(b)(1-2) 2030001 -Records of release detection monitoring and maintenance properly ■ OUT ■ R ■ COS <br /> maintained (TCR 9d) <br /> 60 25281.5(b)(3) 2030020-Unburied fuel piping visually inspected at least monthly and log kept ❑ OUT ❑ R ❑ COS <br /> 61 2643(d) 2030049-Monitoring conducted and written records maintained for SW ❑ OUT ❑ R ❑ COS <br /> conventional suction system(TCR 9d) <br /> 62 25281.5(b)(2) 2030032-Unburied fuel piping at marinas visually inspected at least daily and log ❑ OUT ❑ R ❑ COS <br /> kept <br /> 63 2646.1(d) 2030057-The facility met all corrective action requirements when SIR results failed ❑ OUT ❑ R ❑ COS <br /> 64 2643(b)(2), 2646.1 2030058-All Statistical Inventory Reconciliation (SIR)requirements met(TCR 9d) ❑ OUT ❑ R ❑ COS <br /> 65 25293 2010012-UST records sufficiently maintained to document compliance ❑ OUT ❑ R ❑ COS <br /> 66 2712(b)(6) 2010008-Monitoring, maintenance, repairs, linings, and upgrade records ❑ OUT ❑ R ❑ COS <br /> maintained for life of UST <br /> 67 2712(i) 2030078-Owner/Operator retained a paper or electronic copy of the permit to ❑ OUT ❑ R ❑ COS <br /> operate at the facility <br /> 68 2712(i), 2634(e) 2030046-A current UST Response Plan has been submitted ❑ OUT ❑ R ❑COS <br /> 69 2712(i) 2030033-A current UST monitoring plan has been submitted and is readily ❑ OUT ❑ R ❑ COS <br /> accessible at the facility <br /> 70 2620(b); HSC 25284(a) 2030037-Facility has a current written owner/operator agreement ❑ OUT ❑ R ❑ COS <br /> (3) <br /> 71 2651; HSC 25294 2030061 -Any unauthorized release from the primary containment recorded ❑ OUT ❑ R ❑ COS <br /> 72 2712 2030039-Compliance with all operating permit requirements ❑ OUT ❑ R ❑COS <br /> 73 25281.6(a) 2030059-UST system below ground connected to a E Gen system in compliance ❑ OUT ❑ R ❑ COS <br /> with exclusion/exemption req's <br /> 74 25283.5(a) 2030076-Tank system located in below grade structure meets the exemption ❑ OUT ❑ R ❑ COS <br /> conditions <br /> 75 2715(c)(2) 2030014-Owner/Operator received approval and has implemented a training ❑ OUT ❑ R ❑ COS <br /> program at an unstaffed facility <br /> 76 2630,2632, 2643, 2644.1 2030015-Facility demonstrated that methods used to monitor the UST system ❑ OUT ❑ R ❑ COS <br /> complies with standards (TCR 9d) <br /> 77 2712(f) 2030073-Facility has corrected cited violations within 30 days of receiving report ❑ OUT ❑ R ❑ COS <br /> EHD-CUPA Inspection Report IS02 Page 3 of 5 FA0006440 PR0504967 4573446 11/5/2025 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.