Laserfiche WebLink
SAN aOAQUIN Environmental Health Department <br /> COUNTY— <br /> Greatness grows here. <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SHERIFFS OPERATIONS CTR#2 17000 N MICHAEL CANLIS BLVD FRENCH CAMP I November 05 2025 <br /> 78 2650(e), 2652 2030077-Owner/Operator notified/prepared report upon discovery of unauthorized ❑OUT ❑ R ❑ COS <br /> release (TCR 9d) <br /> 79 2717.1(g) 2030045-Red Tag information is legible and has not been removed or tampered ❑ OUT ❑ R ❑ COS <br /> with <br /> 80 2717.1(f); HSC 25292.3 2030044-Facility did not deposit/allow deposit of petroleum or a hazardous ❑ OUT ❑ R ❑ COS <br /> (c) substance into a red tagged UST <br /> 81 25292.3(c)(1)(C) 2030079-Facility did not dispense petroleum or a hazardous substance from a ❑ OUT ❑ R ❑ COS <br /> UST that has been red tagged <br /> 82 2670(b)(e)(f), 2671 2030063-Facility is in compliance with temporary closure requirements ❑ OUT ❑ R ❑COS <br /> 83 25298(c); CCR 2670, 2030038-UST system properly closed and complies with permanent closure ❑ OUT ❑ R ❑ COS <br /> 2672 requirements <br /> 84 25392.4(d),25292.5(c) 2030066-Repaired/retested any leaks found when ELD testing a UST within 1,000 ❑ OUT ❑ R ❑ COS <br /> feet of a public water well <br /> 85 2631(a); HSC 25290.1(c) 2060027-Tank system primary containment is constructed, operated, and ❑ OUT ❑ R ❑ COS <br /> maintained product-tight. <br /> 86 2631.1, 2660(m) 2060024-UST system is made of or lined with materials that are compatible with ❑ OUT ❑ R ❑ COS <br /> the substance stored. <br /> 87 2631(c), 2662(d) 2060021 -Striker plate installed and positioned correctly. ❑ OUT ❑ R ❑COS <br /> 88 2631(b&d), 2666(b&e) 2060007-Primary and secondary containment designed and constructed to an ❑ OUT ❑ R ❑COS <br /> engineering specification. <br /> 89 25290.1(j) 2060008-Enhanced leak detection testing performed before the tank is placed in ❑ OUT ❑ R ❑ COS <br /> use <br /> 90 2666(b)(2) 2060029-SW piping has been upgraded to continuously monitored DW piping ❑ OUT ❑ R ❑ COS <br /> when replacement or repair needed <br /> 91 25291(e) 2010-Administration/Documentation-General ❑ OUT ❑ R ❑ COS <br /> 92 2015-Administrative/Documentation-General Local Ordinance ❑ OUT ❑ R ❑ COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 10 2638(c), 2638(d) 2030074-Annual Monitoring System Certification Form to the CUPA within 30 days of completion of <br /> the test <br /> OBSERVATION: Annual spill bucket testing was performed on 11/12/2024 and a test report was submitted on 11/3/2025, <br /> 356 days late. <br /> REGULATION GUIDANCE: A copy of the test report must be submitted within 30 days of the tests. <br /> CORRECTIVE ACTION: Take all necessary precautions to ensure testing and submittal of test reports are performed in <br /> a timely manner. <br /> OBSERVATION: A monitoring system certification and leak detector testing was performed on 11/12/2024 and submitted <br /> 11/3/2025, 356 days late. The Service Technician, Zane Nemo listed on the report did not have the appropriate <br /> certification to perform the test. The test results will not be accepted. <br /> REGULATION GUIDANCE: A copy of the test report must be submitted within 30 days of the test. <br /> CORRECTIVE ACTION: Immediately provide the report with a certified Service Technician to the EHD. <br /> This is a (Minor)Violation. <br /> EHD-CUPA Inspection Report IS02 Page 4 of 5 FA0006440 PR0504967 4573446 11/5/2025 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />