My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
2057
>
2300 - Underground Storage Tank Program
>
PR0231083
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2026 11:39:15 AM
Creation date
2/5/2025 8:03:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231083
PE
2361 - UST FACILITY
FACILITY_ID
FA0003735
FACILITY_NAME
Top Gas Corporation
STREET_NUMBER
2057
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16515309
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
2057 S EL DORADO ST STOCKTON 95206
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A dOAQU1N Environmental Health Department <br /> COUNTY <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: 72057 <br /> ty Address: Date: <br /> STOCKTON FOOD&GAS#2 S ELDORADO ST, STOCKTON FehruarV 12 2025 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> This is (Minor)Violation. <br /> 28 CA Code of Regulations 2638(a),2641 Q)2030043- Leak detection equipment properly installed, calibrated, operated, <br /> and maintained (TCR 9d). <br /> OBSERVATION: The Veeder Root 208 sensor located in the 87 STP sump was found hanging from an electrical pipe <br /> within the sump, lifted approximately 8 inches above the lowest point of the sump.Approximately 3 inches below the <br /> lifted 208 sensor was about 25 gallons of water. <br /> REGULATION GUIDANCE:All monitoring equipment shall be installed, calibrated, operated, and maintained in <br /> accordance with manufacturer's instructions, and certified for operability, proper operating condition, and proper <br /> calibration. <br /> CORRECTIVE ACTION: Service technician relocated sensor and ensured sensor is properly maintained according to <br /> manufacturer's instructions. <br /> This was corrected on site. <br /> This is (Class 2)Violation. <br /> 30 CA Code of Regulations 2630(d),2641(a)2060015-Leak detection equipment located so leak is detected at the <br /> earliest possible opportunity(TCR 9d). <br /> OBSERVATION:The VR 208 sensor located in the 87 STP Sump was raised approximately 8 inches off the lowest <br /> point of the sump and not located to detect a leak at the earliest opportunity. <br /> REGULATION GUIDANCE: Monitoring equipment shall be maintained to be able to detect a leak at the earliest <br /> possible opportunity. <br /> CORRECTIVE ACTION: The sensor was relocated to the lowest point of the sump by the service technician. Ensure <br /> that all monitoring equipment is maintained and located to detect a leak at the earliest opportunity. <br /> This is a repeat violation (Class 2) Violation. <br /> 31 CA Health and Safety Code 25299(a)(9)2030062-Leak detection equipment has not been tampered with or disabled <br /> (TCR 9d). <br /> OBSERVATION:The Veeder Root 208 sensor located in the 87 STP sump was found hanging from an electrical pipe <br /> within the sump, lifted approximately 8 inches above the lowest point of the sump.Approximately 3 inches below the <br /> lifted 208 sensor was about 25 gallons of liquid. <br /> REGULATION GUIDANCE:An operator of an underground storage tank system shall not allow tampering with or <br /> otherwise disabling automatic leak detection devices or alarms. <br /> CORRECTIVE ACTION: The sensor was relocated to the lowest point of the sump by the service technician. Ensure <br /> that all monitoring equipment is maintained and located to detect a leak at the earliest opportunity. <br /> This is (Class 1)Violation. <br /> 50 CA Code of Regulations 2635, 2637.1, 2665, 2712 2060020-Spill buckets meet requirements, have been tested as <br /> FA0003735 PR0231083 SCO01 02/12/2025 <br /> EHD Rev.12/06/2021 Page 6 of 11 CP22-UST FULL OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />