My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
2072
>
2300 - Underground Storage Tank Program
>
PR0231426
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2026 8:44:46 PM
Creation date
2/5/2025 8:21:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231426
PE
2361 - UST FACILITY
FACILITY_ID
FA0004625
FACILITY_NAME
NATIONAL PETROLEUM MANTECA
STREET_NUMBER
2072
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
22202001
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
2072 W YOSEMITE AVE MANTECA 95337
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A dOAQU1N Environmental Health Department <br /> COUNTY <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> NATIONAL PETROLEUM MANTECA 2072 W YOSEMITE AVE, MANTECA September 17 2024 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> responsibility documents in CERS are dated 1/15/2023. <br /> REGULATION GUIDANCE: Current financial responsibility documents are required to be submitted annually. <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov/, and upload the required documents. <br /> This is a repeat violation (Class 2) Violation. <br /> 56 CA Code of Regulations 2716(a-e)2030013-DO inspections completed at least every 30 days and meet all <br /> requirements(TCR 12). <br /> OBSERVATION:The designated operator failed to document all the alarms from the attached alarm history on the <br /> 5/28/2024 designated operator inspection report and failed to check that they were responded to appropriately. The <br /> missing alarms include: <br /> - L4 May 24, 2024 Fuel Alarm <br /> REGULATION GUIDANCE: During the inspection,the designated operator shall review the alarm history since the <br /> previous inspection, check that each alarm was documented and responded to appropriately, and attach a copy of the <br /> alarm history with documentation taken in response to any alarms to the inspection report. <br /> CORRECTIVE ACTION: Ensure that designated operators performing inspections at this facility are including all of the <br /> required information on the reports. <br /> This is a repeat violation (Class 2) Violation. <br /> 66 CA Code of Regulations 2712(b)(6)2010008-Monitoring, maintenance, repairs, linings, and upgrade records <br /> maintained for life of UST. <br /> OBSERVATION: Received notification for replacement of H style relay on grade 91,work order was not found on site. <br /> REGULATION GUIDANCE:These records shall be kept on site for the life of the tank. <br /> CORRECTIVE ACTION: Immediately locate and maintain these records on site and submit copies to the EHD. <br /> This is a repeat violation (Class 2) Violation. <br /> 72 CA Code of Regulations 2712 2030039-Compliance with all operating permit requirements. <br /> OBSERVATION:The facility is not in compliance with the written conditions of the operating permit. The racing fuel <br /> 100 and 110 tanks leak detector annual testing has not been conducted. <br /> REGULATION GUIDANCE:The owner and operator of underground storage tank(UST)systems shall comply with all <br /> requirements of the permit issued for the operation of the UST system. <br /> CORRECTIVE ACTION: Immediately take all necessary actions to bring these UST systems into compliance to avoid <br /> the tanks being red tagged. <br /> This is a repeat violation (Class 2) Violation. <br /> 77 CA Code of Regulations 2712(f)2030073- Facility has corrected cited violations within 30 days of receiving report. <br /> FA0004625 PR0231426 SCO01 09/17/2024 <br /> EHD Rev.12/06/2021 Page 8 of 9 CP22-UST FULL OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.