COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
7707
>
2800 - Aboveground Petroleum Storage Program
>
PR0538333
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 11:19:11 AM
Creation date
2/24/2025 11:18:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0538333
PE
2832 - AST FAC 10 K - </=100 K GAL CUMULATIVE
FACILITY_ID
FA0021992
FACILITY_NAME
CDCR-California Health Care Facility
STREET_NUMBER
7707
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
Stockton
Zip
95215
APN
181-100-11
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
7707 Austin RD Stockton 95215
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />CP22 - AST Non-Qualified Inspection Report <br />Date: <br />September 25, 2024 <br /> Facility Address: <br /> 7707 Austin RD, Stockton <br /> Facility Name: <br /> CDCR-California Health Care Facility <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />records signed, kept for 3 years. <br />OBSERVATION: The facility was not able to provide the following during the inspection: <br />-Monthly and annual SP001 inspection reports for the petroleum tanks at the CHCF. Per Correctional Plant Manager <br />II Nikolas Corren, CHCF did not have any monthly inspections. <br />-Annual SP001 inspection reports for the petroleum tanks at the NCYCC. <br />-Monthly SP001 portable container inspection checklists for both the CHCF and NCYCC. <br />REGULATION GUIDANCE: 112.7(e) Conduct inspections and tests required by this part in accordance with written <br />procedures that you or the certifying engineer develop for the facility. <br />CORRECTIVE ACTION: Immediately begin conducting all inspections and tests in accordance with the procedures <br />outlined in the SPCC Plan and begin using forms provided by the SPCC plan. Keep written inspection procedures and <br />records of inspections and testing signed by the appropriate supervisor/inspector for at least three years. Submit proof <br />of correction to the EHD. <br />This is a repeat violation (Class 2) Violation. <br />Code of Fed Regulations 112.7(a)(1), 112.8(c)(8) 4010056 - SPCC adequately describes overfill prevention methods, <br />and devices/systems used for each container. <br />OBSERVATION: The Spill Prevention, Control, and Countermeasure (SPCC) Plan failed to adequately describe the <br />overfill prevention methods, including a description of the devices or systems in place for each container to prevent <br />overfills for the generators located at the NCYCC. <br />REGULATION GUIDANCE: 112.7 (a)(1) Include a discussion of your facility's conformance with the requirements listed <br />in this part [§112.7]. 112.8 (c)(8) Engineer or update each container installation in accordance with good engineering <br />practice to avoid discharges. You must provide at least one of the following devices : (i) High liquid level alarms with an <br />audible or visual signal at a constantly attended operation or surveillance station. In smaller facilities an audible air <br />vent may suffice. (ii) High liquid level pump cutoff devices set to stop flow at a predetermined container content level . <br />(iii) Direct audible or code signal communication between the container gauger and the pumping station. (iv) A fast <br />response system for determining the liquid level of each bulk storage container such as digital computers, telepulse, <br />or direct vision gauges. If you use this alternative, a person must be present to monitor gauges and the overall filling of <br />bulk storage containers. (v) You must regularly test liquid level sensing devices to ensure proper operation . <br />CORRECTIVE ACTION: The SPCC plan shall adequately address overfill prevention methods, including a description <br />of the devices or systems in place for each container to prevent overfills. Provide proof of correction to the EHD. <br />This is (Class 2) Violation. <br /> 59 <br />Code of Fed Regulations 112.20(e) 4010044 - Substantial Harm Criteria certification maintained at the facility as <br />required. <br />OBSERVATION: The facility failed to complete and maintain (at the facility) the Substantial Harm Criteria certification <br />form, and Associate Hazardous Materials Specialist Anthony Vanni determined that the facility could not be <br />reasonably expected to cause substantial harm to the environment. The Substantial Harm Criteria certification form <br />was not signed in the plan. <br />REGULATION GUIDANCE: (e) If the owner or operator of a facility determines pursuant to paragraph (a)(2) of this <br /> 78 <br />FA0021992 PR0538333 SC001 09/25/2024 <br />EHD Rev. 12/06/2021 CP22 - AST Non-Qualified OIRPage 10 of 11 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD