Environmental Health Department <br />CP22 - AST Non-Qualified Inspection Report <br />Date: <br />October 17, 2024 <br /> Facility Address: <br /> 18260 S Harlan RD, Lathrop <br /> Facility Name: <br /> Tesla Lathrop <br /> □ OUT □ R □ COS4010024 - SPCC addresses security measures-lighting, access to handling/storage, <br />valves/pumps/transfer equip <br />Code of Fed <br />Regulations 112.7(g) <br /> 48 <br /> □ OUT □ R □ COS4030001 - Handling areas, valves, pumps/starter controls, load/unload connections secured, <br />lighting adequate <br />Code of Fed <br />Regulations 112.7(g) <br /> 49 <br /> □ OUT □ R □ COS4010025 - SPCC adequately discusses facility tank car and tank truck loading/unloading rackCode of Fed <br />Regulations 112.7(h) <br /> 50 <br /> □ OUT □ R □ COS4030002 - Loading rack containment has capacity to contain single largest compartment of tank <br />car/truck <br />Code of Fed <br />Regulations 112.7(h)(1) <br /> 51 <br /> □ OUT □ R □ COS4030003 - Vehicular departure warning system in place at facility with a loading/unloading rackCode of Fed <br />Regulations 112.7(h)(2) <br /> 52 <br /> □ OUT □ R □ COS4010040 - Documented evaluation of field-constructed tanks for risk of discharge due to brittle <br />fracture <br />Code of Fed <br />Regulations 112.7(i) <br /> 53 <br /> □ OUT □ R □ COS4030034 - Oil filled operational equipment containment standards are metCode of Fed <br />Regulations 112.7(k) <br /> 55 <br /> □ OUT □ R □ COS4010027 - Facility drainage or drainage controls adequately discussedCode of Fed <br />Regulations 112.7(a)(3) <br />(iii) <br /> 56 <br /> □ OUT □ R □ COS4030035 - Facility drainage adequately restrained unless conditions metCode of Fed <br />Regulations 112.8(b)(1) <br /> 57 <br /> □ OUT □ R □ COS4030005 - Valves used for drainage are manual (not flapper-type) to prevent a dischargeCode of Fed <br />Regulations 112.8(b)(2) <br /> 58 <br /> □ OUT □ R □ COS4030008 - Drainage from undiked areas or diversion systems designed to retain final discharge in <br />facility <br />Code of Fed <br />Regulations 112.8(b) <br />(3), 112.8(b)(4) <br /> 59 <br /> □ OUT □ R □ COS4030009 - Lift pumps provided for treated drainage waters when more than one treatment unitCode of Fed <br />Regulations 112.8(b)(5) <br /> 60 <br /> □ OUT □ R □ COS4010029 - Adequate discussion of all bulk storage containers located at the facilityCode of Fed <br />Regulations 112.8(c) <br /> 61 <br /> □ OUT □ R □ COS4030012 - Material and construction of all containers are compatible with the material storedCode of Fed <br />Regulations 112.8(c)(1) <br /> 62 <br /> □ OUT □ R □ COS4030010 - Adequately sized secondary containment provided and maintained for bulk storage <br />containers <br />Code of Fed <br />Regulations 112.8(c)(2) <br /> 63 <br /> □ OUT □ R □ COS4030043 - Secondary containment and/or leak detection provided for TIUGA piping if not viewable <br />on all sides <br />CA Health and Safety <br />Code 25270.2(o)(1)(C) <br />(iv) <br /> 64 <br /> □ OUT □ R □ COS4030006 - Rainwater in diked areas is inspected before drainingCode of Fed <br />Regulations 112.8(c)(3) <br /> 66 <br /> □ OUT □ R □ COS4010026 - Records maintained of drainage from diked areasCode of Fed <br />Regulations 112.8(c)(3) <br />(iv) <br /> 67 <br /> □ OUT □ R □ COS4030017 - Buried section of partially buried or bunkered metallic tank has corrosion protectionCode of Fed <br />Regulations 112.8(c)(5) <br /> 68 <br /> □ OUT □ R □ COS4010028 - SPCC discusses procedures to test/inspect storage containers for integrity per industry <br />standards <br />Code of Fed <br />Regulations 112.8(c)(6) <br /> 69 <br /> □ OUT □ R □ COS4030015 - Aboveground containers tested or inspected for integrity based on industry standardsCode of Fed <br />Regulations 112.7(e), <br />112.8(c)(6) <br /> 71 <br /> □ OUT □ R □ COS4010021 - Written Inspection /testing procedures kept, inspection/testing records signed, kept for 3 <br />years <br />Code of Fed <br />Regulations 112.7(e), <br />112.8(c)(6) <br /> 72 <br /> □ OUT □ R □ COS4030018 - Steam return/exhaust lines that discharge to watercourse are monitored or have <br />treatment system <br />Code of Fed <br />Regulations 112.8(c)(7) <br /> 73 <br />FA0013586 PR0544269 SC001 10/17/2024 <br />EHD Rev. 12/06/2021 CP22 - AST Non-Qualified OIRPage 3 of 12 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD