My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
18260
>
2800 - Aboveground Petroleum Storage Program
>
PR0544269
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 2:41:35 PM
Creation date
2/24/2025 2:37:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0544269
PE
2832 - AST FAC 10 K - </=100 K GAL CUMULATIVE
FACILITY_ID
FA0013586
FACILITY_NAME
Tesla Lathrop
STREET_NUMBER
18260
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
Lathrop
Zip
95330
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
18260 S Harlan RD Lathrop 95330
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />CP22 - AST Non-Qualified Inspection Report <br />Date: <br />October 17, 2024 <br /> Facility Address: <br /> 18260 S Harlan RD, Lathrop <br /> Facility Name: <br /> Tesla Lathrop <br /> □ OUT □ R □ COS4010056 - SPCC adequately describes overfill prevention methods, and devices/systems used for <br />each container <br />Code of Fed <br />Regulations 112.7(a) <br />(1), 112.8(c)(8) <br /> 74 <br /> □ OUT □ R □ COS4030019 - Each container installation has a liquid level sensing device.Code of Fed <br />Regulations 112.8(c) <br />(8), 25270.4.5(a) <br /> 75 <br /> □ OUT □ R □ COS4030022 - Liquid level sensing devices regularly tested to ensure proper operationCode of Fed <br />Regulations 112.8(c)(8) <br />(v) <br /> 76 <br /> □ OUT □ R □ COS4030023 - Discharge from effluent treatment facilities which discharge to navigable waterways <br />observed <br />Code of Fed <br />Regulations 112.8(c)(9) <br /> 77 <br /> □ OUT □ R □ COS4030021 - Visible discharges promptly corrected and any accumulation of oil in diked areas <br />promptly removed. <br />Code of Fed <br />Regulations 112.8(c) <br />(10) <br /> 78 <br /> □ OUT □ R □ COS4030020 - Adequate secondary containment provided for mobile/portable storage containersCode of Fed <br />Regulations 112.8(c) <br />(11) <br /> 79 <br /> □ OUT □ R □ COS4030025 - Buried piping is inspected for deterioration if exposed and repaired if corrosion damage <br />is found <br />Code of Fed <br />Regulations 112.8(d)(1) <br /> 80 <br /> □ OUT □ R □ COS4030027 - Buried piping is corrosion protected with protective wrapping, coating, or cathodic <br />protection <br />Code of Fed <br />Regulations 112.8(d)(1) <br /> 81 <br /> □ OUT □ R □ COS4030028 - Terminal connection capped /blank flanged at transfer point & origin marked if not in <br />service/standby <br />Code of Fed <br />Regulations 112.8(d)(2) <br /> 82 <br /> □ OUT □ R □ COS4030029 - Pipe supports designed to minimize abrasion and corrosion, and allow for expansion <br />and contraction <br />Code of Fed <br />Regulations 112.8(d)(3) <br /> 83 <br /> □ OUT □ R □ COS4030026 - Aboveground valves, piping, and appurtenances are regularly inspectedCode of Fed <br />Regulations 112.8(d)(4) <br /> 84 <br /> □ OUT □ R □ COS4030030 - Integrity/leak tested buried piping when installed, modified, constructed, relocated, or <br />replaced <br />Code of Fed <br />Regulations 112.8(d)(4) <br /> 85 <br /> □ OUT □ R □ COS4030031 - Vehicle traffic warned of aboveground piping or other oil transfer operationsCode of Fed <br />Regulations 112.8(d)(5) <br /> 86 <br /> □ OUT □ R □ COS4030044 - Excluded TIUGA <55 gal has secondary containment, inspected monthly and log of <br />inspections kept <br />CA Health and Safety <br />Code 25270.2(a)(8) <br /> 87 <br /> □ OUT □ R □ COS4010037 - Oil filled electrical equipment exclusions have been met, and where not met is included <br />in SPCC plan <br />CA Health and Safety <br />Code 25270.2(a)(4), <br />25270.4.5 <br /> 88 <br /> □ OUT □ R □ COS4010032 - Tank Facility Statement or Business Plan has been submittedCA Health and Safety <br />Code 25270.6(a) <br /> 89 <br /> □ OUT □ R □ COS4010033 - APSA program fee paidCA Health and Safety <br />Code 25270.6(b) <br /> 91 <br /> □ OUT □ R □ COS4030036 - All/any permanently closed tanks are properly closed under the definition in 40 CFR <br />112.2 <br />Code of Fed <br />Regulations 112.1(b) <br />(3), 112.2 <br /> 92 <br /> □ OUT □ R □ COS4010044 - Substantial Harm Criteria certification maintained at the facility as requiredCode of Fed <br />Regulations 112.20(e) <br /> 93 <br /> □ OUT □ R □ COS4010 - Administration/Documentation - GeneralCA Health and Safety <br />Code 25404(e)(4) <br /> 94 <br /> □ OUT □ R □ COS4015 - Administration/Documentation - General Local Ordinance 95 <br /> □ OUT □ R □ COS4020 - Training - General See below 96 <br /> □ OUT □ R □ COS4025 - Training - General Local Ordinance 97 <br />FA0013586 PR0544269 SC001 10/17/2024 <br />EHD Rev. 12/06/2021 CP22 - AST Non-Qualified OIRPage 4 of 12 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page