My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
116
>
2300 - Underground Storage Tank Program
>
PR0523684
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/7/2026 2:09:55 PM
Creation date
4/3/2025 3:39:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0523684
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0015977
FACILITY_NAME
Fast Lane Central Valley
STREET_NUMBER
116
STREET_NAME
ROTH
STREET_TYPE
RD
City
Lathrop
Zip
95330
APN
19602020
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
116 Roth RD Lathrop 95330
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
149
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANsJOAQUIN AMENDED Environmental Health Department <br /> COUNTY 7/7/2025 <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Fast Lane Central Vallev 1116 Roth RD, Lathrop TJuly 07, 2025 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 3 CA Code of Regulations 2632(d)(1), 2634(d) 2010013 - Facility has submitted a complete and accurate UST <br /> Monitoring Plan. <br /> OBSERVATION: The monitoring plan is not approved by the EHD. The monitoring plan for Tank 4 lists VMI as the <br /> manufacturer of the VR FX1 DV leak detector. <br /> REGULATION GUIDANCE: The monitoring plan must be uploaded to the California Environmental Reporting System <br /> (CERS). <br /> CORRECTIVE ACTION: Immediately log into CERS, make the necessary changes, and submit for review by the EHD. <br /> This is a (Class 2)Violation. <br /> 9 CA Code of Regulations 2638, 26410), 2715(f) 2030002 - Leak detection equipment tested by qualified service <br /> technician every 12 months (TCR 9d) <br /> OBSERVATION: Annual monitoring system certification and leak detector testing were previously performed on <br /> 6/27/2024 and was completed on 7/7/2025, 1 month past due. <br /> REGULATION GUIDANCE: These tests are required once every 12 months. <br /> CORRECTIVE ACTION: Take all necessary precautions to ensure testing is performed in a timely manner. <br /> OBSERVATION: The annual monitoring system certification and leak detector testing were last performed on 6/27/2024 <br /> and were due by June 2025. Testing has not been completed for the auto fueling side and is 1 month past due. <br /> REGULATION GUIDANCE: These tests are required once every 12 months. <br /> CORRECTIVE ACTION: Immediately schedule these tests and provide 48 hours notification to the EHD. <br /> Please be aware that all EHD staff time associated with a follow up inspection will be billed at our current hourly rate <br /> ($179). <br /> This is a Repeat(Class 2)Violation. <br /> 47 CA Health and Safety Code 25290.1(0), 25290.2(c3) 2030008 - Secondary containment installed after July 1, 2003 is <br /> free of water <br /> OBSERVATION: Water was found in the diesel 1 (T1) and diesel 2 (T2) STP piping sumps, diesel 2 fill piping sump, <br /> UDC 1/2, UDC 5/6, and the truck side vent piping sump. <br /> REGULATION GUIDANCE: Secondary containment shall be constructed to prevent any water intrusion into the system <br /> by precipitation, infiltration, or surface runoff. <br /> CORRECTIVE ACTION: Immediately remove this liquid, make a hazardous waste determination per Title 22 hazardous <br /> waste regulations, and manage accordingly. Immediately contact a properly licensed, trained, and certified contractor to <br /> address the water intrusion into the diesel 1 (T1) and diesel 2 (T2) STP piping sumps, diesel 2 fill piping sump, UDC 1/2, <br /> UDC 5/6, and the truck side vent piping sump under permit and inspection of the EHD, if needed. <br /> This is a Repeat(Class 2)Violation. <br /> EHD-CUPA Inspection Report IS02 Page 5 of 6 FA0015977 PRO523684 4522224 7/7/2025 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.