Laserfiche WebLink
SANsJOAQUIN Environmental Health Department <br /> COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> A TEICHERT& SON INC* 1120 FRANK WEST CIR, STOCKTON September 11, 2025 <br /> 52 CA Code of Regulations 2635(c)(1) 2030036 - Overfill prevention system has not been overridden and meets overfill <br /> requirements (TCR 9b) <br /> OBSERVATION: The waste oil underground storage tank does not have an approved overfill prevention system. <br /> REGULATION GUIDANCE: All underground storage tanks shall be equipped with an overfill prevention system that does <br /> not allow for manual override and meets one of the following requirements: <br /> 1. Alert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or triggering an audible <br /> and visual alarm; or <br /> 2. Restrict delivery of flow to the tank at least 30 minutes before the tank overfills, provided the restriction occurs when <br /> the tank is filled to no more than 95 percent of capacity; and activate an audible alarm at least five minutes before the <br /> tank overfills; or <br /> 3. Provide positive shut-off of flow to the tank when the tank is filled to no more than 95 percent of capacity; or, <br /> 4. Provide positive shut-off of flow to the tank so that none of the fittings located on the top of the tank are exposed to <br /> product due to overfilling. <br /> CORRECTIVE ACTION: Immediately contact a properly licensed, trained, and certified contractor to install an approved <br /> overfill prevention system. Replacement of a mechanical flapper valve requires a permit and inspection by the EHD. If <br /> an external audio/visual alarm is replaced, provide a copy of the service receipt to the EHD. If an approved overfill <br /> prevention system can't be installed immediately, there is a possibility that the waste oil UST system may be red tagged <br /> to prevent fuel inputs. <br /> This is a Repeat(Class 2)Violation. <br /> 55 CA Code of Regulations 2716(f) 2010004- Copies of DO inspections for last 12 months maintained, 36 months for <br /> those after 10/1/18 (TCR 12) <br /> OBSERVATION: The designated operator inspection reports prior to 01/05/2024 were not found on site. <br /> REGULATION GUIDANCE: Designated operator inspection reports prior to October 1, 2018 shall be retained on site for <br /> twelve months. Designated operator inspection reports on or after October 1, 2018 shall be retained on site for thirty-six <br /> months. <br /> CORRECTIVE ACTION: Locate and ensure that copies of the previous thirty-six months of designated operator <br /> inspection reports are maintained on site. Submit copies of the missing reports to the EHD. <br /> This is a (Minor)Violation. <br /> Overall Inspection Comments <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting paperwork, <br /> by October 11, 2025. <br /> To minimize person to person contact EHD is choosing to write the name of person receiving the report instead of <br /> having them sign. Starting July 1, 2025, all in-office CERS help will be provided at EHD hourly rate ($179). To <br /> schedule an appointment, please call (209) 468-3420. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING THIS <br /> FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: September 11, 2025 Inspector: Inspector Phone: <br /> Printed Name and Title: Allen ASIo, EHS (209)616-3031 <br /> Nic Armstrong, Compliance <br /> Manager <br /> EHD-CUPA Inspection Report IS02 Page 6 of 6 FA0012107 PR0515365 4549715 9/11/2025 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />