My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ESCALON BELLOTA
>
4469
>
2800 - Aboveground Petroleum Storage Program
>
PR0540158
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2025 2:25:26 PM
Creation date
4/17/2025 2:23:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0540158
PE
2832 - AST FAC 10 K - </=100 K GAL CUMULATIVE
FACILITY_ID
FA0019881
FACILITY_NAME
FARMINGTON CIRCLE K
STREET_NUMBER
4469
Direction
S
STREET_NAME
ESCALON BELLOTA
STREET_TYPE
RD
City
FARMINGTON
Zip
95230
APN
18713010
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
4469 S ESCALON BELLOTA RD FARMINGTON 95230
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />CP22 - AST Non-Qualified Inspection Report <br />Date: <br />March 20, 2025 <br /> Facility Address: <br /> 4469 S ESCALON BELLOTA RD, FARMINGTON <br /> Facility Name: <br /> FARMINGTON CIRCLE K <br /> □ OUT □ R □ COS4045 - Release/Leaks/Spills - General Local Ordinance 86 <br /> □ OUT □ R □ COS4050 - Abandonment/Illegal Disposal/Unauthorized Treatment - General See below 87 <br /> □ OUT □ R □ COS4055 - Abandonment/Illegal Disposal/Unauthorized Treatment - General Local Ordinance 88 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />Code of Fed Regulations 112.7 4010012 - SPCC in writing, follows code seq/cross ref, good eng practice, mgt <br />approval, items not in place. <br />OBSERVATION: The Spill Prevention, Control, and Countermeasure (SPCC) Plan reviewed at the time of inspection, <br />dated 3/27/2024, did not follow the order or requirements of 40 CFR Part 112.7. <br />- In the section, "Discharge Prevention Measures", it states that to review monthly inspection reports for the AST and <br />portable containers to refer to "Attachment 2". Attachment 2 was reviewed and titled as "Discharge Prevention <br />Measures". Therefore, the plan does not include adequate cross-reference. <br /> <br />REGULATION GUIDANCE: The plan must include adequate cross reference <br />CORRECTIVE ACTION: Ensure that your SPCC Plan complies with the following requirements: It follows the required <br />SPCC rule sequence and/or includes adequate cross-reference. Provide proof of correction to the EHD. <br />This is (Minor) Violation. <br /> 11 <br />Code of Fed Regulations 112.7(a)(3vi), 112.7(a4) 4010017 - SPCC contains procedures for reporting a discharge. <br />OBSERVATION: The Spill Prevention, Control, and Countermeasure (SPCC) Plan does not adequately discuss <br />procedures for reporting a discharge. <br />- The plan does not include names of individuals/organizations contacted in the event of a discharge. <br />REGULATION GUIDANCE: Unless you have submitted a response plan under § 112.20, provide information and <br />procedures in your Plan to enable a person reporting a discharge as described in § 112.1(b) to relate information on <br />the exact address or location and phone number of the facility; the date and time of the discharge, the type of material <br />discharged; estimates of the total quantity discharged; estimates of the quantity discharged as described in § <br />112.1(b); the source of the discharge; a description of all affected media ; the cause of the discharge; any damages or <br />injuries caused by the discharge; actions being used to stop, remove, and mitigate the effects of the discharge ; <br />whether an evacuation may be needed; and, the names of individuals and/or organizations who have also been <br />contacted. <br />CORRECTIVE ACTION: Immediately amend the SPCC Plan to include names of individuals/organizations contacted <br />in the event of a discharge. Submit proof of correction to the EHD. <br />This is (Minor) Violation. <br /> 20 <br />Code of Fed Regulations 112.7(b) 4010019 - SPCC predicts direction, rate of flow, total quantity of oil that could be <br />released from a discharge. <br />OBSERVATION: The Spill Prevention, Control, and Countermeasure (SPCC) Plan failed to predict the direction, rate <br />of flow, and the total quantity of the oil that could be discharged for each type of major equipment failure. The potential <br />equipment failure and the resulting spill from the tanks was not addressed in the SPCC Plan. <br /> 22 <br />FA0019881 PR0540158 SC001 03/20/2025 <br />EHD Rev. 12/06/2021 CP22 - AST Non-Qualified OIRPage 5 of 8 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.