My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
601
>
2300 - Underground Storage Tank Program
>
PR0231348
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/8/2026 12:07:24 PM
Creation date
5/2/2025 11:23:30 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231348
PE
2361 - UST FACILITY
FACILITY_ID
FA0003803
FACILITY_NAME
KETTLEMAN CHEVRON
STREET_NUMBER
601
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04728006
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
601 E KETTLEMAN LN LODI 95240
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A dOAQU1N Environmental Health Department <br /> COUNTY <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> KETTLEMAN CHEVRON 601 E KETTLEMAN LN LODI i Uly 24 2025 <br /> 86 CA Code of Regulations 2060024-UST system is made of or lined with materials that are compatible with the substance ❑OUT ❑R ❑COS <br /> 2631.1,2660(m) stored. <br /> 87 CA Code of Regulations 2060021-Striker plate installed and positioned correctly. ❑OUT ❑R ❑COS <br /> 2631(c),2662(d) <br /> 88 CA Code of Regulations 2060007-Primary and secondary containment designed and constructed to an engineering ❑OUT ❑R ❑COS <br /> 2631(b&d),2666(b&e) specification. <br /> 89 CA Health and Safety 2060008-Enhanced leak detection testing performed before the tank is placed in use ❑OUT ❑R ❑COS <br /> Code 25290.10) <br /> 90 CA Code of Regulations 2060029-SW piping has been upgraded to continuously monitored DW piping when replacement ❑OUT ❑R ❑COS <br /> 2666(b)(2) or repair needed <br /> 91 CA Health and Safety 2010-Administration/Documentation-General ❑OUT ❑R ❑COS <br /> Code 25291(e) <br /> 92 2015-Administrative/Documentation-General Local Ordinance ❑OUT ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 3 CA Code of Regulations 2632(d)(1), 2634(d)2010013- Facility has submitted a complete and accurate UST <br /> Monitoring Plan.. <br /> OBSERVATION:The monitoring plan is not current. <br /> - Based on the completed Service Request SR0087856, all tanks have no ball floats and the overfill Protection Method <br /> is Fill Tube/Shut off Valves.At the time of inspection,the monitoring plan indicates that the Overfill Protection method <br /> is Audible/Visual and that ball floats are present,this is inaccurate. <br /> REGULATION GUIDANCE:The monitoring plan must be uploaded to the California Environmental Reporting System <br /> (CERS). <br /> CORRECTIVE ACTION: Immediately log into CERS, make the necessary changes, and submit for review by the EHD. <br /> This is a repeat violation (Class 2) Violation. <br /> 11 CA Code of Regulations 2637(a-d), 2712(b)(1)(F)2030048-Sec containment testing conducted per requirements& <br /> records kept for 36 mths(TCR 9d). <br /> OBSERVATION: Secondary containment testing was completed on 1/29/2024 and 6/11/2024,the test results were not <br /> found on site at the time of inspection. <br /> REGULATION GUIDANCE:A copy of the test report must be kept on site for 36 months from the date that the testing <br /> was performed. <br /> CORRECTIVE ACTION: Immediately locate the test results and ensure it is kept on site for 36 months from the date <br /> that the testing was performed. Provide a corrective action statement to EHD. <br /> This is (Minor)Violation. <br /> 14 CA Code of Regulations 2637.2(d&e), 2665(a&b)2010018-Overfill prevention equipment inspection report form <br /> submitted to the UPA within 30 days. <br /> OBSERVATION:A repair overfill prevention equipment inspection was performed on 6/11/2024 and a test report was <br /> submitted on 8/7/2024, 27 days late. <br /> REGULATION GUIDANCE:A copy of the test report must be submitted within 30 days of the tests. <br /> FA0003803 PR0231348 SCO01 07/24/2025 <br /> EHD Rev.12/06/2021 Page 5 of 9 CP22-UST FULL OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.