COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DA VINCI
>
4627
>
2300 - Underground Storage Tank Program
>
PR0231074
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2026 9:09:27 PM
Creation date
5/14/2025 9:02:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231074
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0002541
FACILITY_NAME
7-ELEVEN INC #20632
STREET_NUMBER
4627
STREET_NAME
DA VINCI
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
11002003
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
4627 DA VINCI DR STOCKTON 95207
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank Program Inspection Report <br />Date: <br />December 16, 2025 <br />Facility Address: <br />4627 DA VINCI DR, STOCKTON7-ELEVEN INC #20632 <br />Facility Name: <br />Environmental Health Department <br />76 CCR 2630, 2632, 2643, <br />2644.1 <br />2030015 - Facility demonstrated that methods used to monitor the UST system <br />complies with standards (TCR 9d) <br /> OUT R COS <br />77 CCR 2712(f) 2030073 - Facility has corrected cited violations within 30 days of receiving report OUT R COS <br />78 CCR 2650(e), 2652 2030077 - Owner/Operator notified/prepared report upon discovery of unauthorized <br />release (TCR 9d) <br /> OUT R COS <br />79 CCR 2717.1(g) 2030045 - Red Tag information is legible and has not been removed or tampered <br />with <br /> OUT R COS <br />80 CCR 2717.1(f); HSC <br />25292.3(c) <br />2030044 - Facility did not deposit/allow deposit of petroleum or a hazardous <br />substance into a red tagged UST <br /> OUT R COS <br />81 HSC 25292.3(c)(1)(C) 2030079 - Facility did not dispense petroleum or a hazardous substance from a <br />UST that has been red tagged <br /> OUT R COS <br />82 CCR 2670(b)(e)(f), 2671 2030063 - Facility is in compliance with temporary closure requirements OUT R COS <br />83 HSC 25298(c); CCR <br />2670, 2672 <br />2030038 - UST system properly closed and complies with permanent closure <br />requirements <br /> OUT R COS <br />84 HSC 25392.4(d), 25292.5 <br />(c) <br />2030066 - Repaired/retested any leaks found when ELD testing a UST within 1,000 <br />feet of a public water well <br /> OUT R COS <br />85 CCR 2631(a); HSC <br />25290.1(c) <br />2060027 - Tank system primary containment is constructed, operated, and <br />maintained product-tight. <br /> OUT R COS <br />86 CCR 2631.1, 2660(m) 2060024 - UST system is made of or lined with materials that are compatible with <br />the substance stored. <br /> OUT R COS <br />87 CCR 2631(c), 2662(d) 2060021 - Striker plate installed and positioned correctly. OUT R COS <br />88 CCR 2631(b&d), 2666 <br />(b&e) <br />2060007 - Primary and secondary containment designed and constructed to an <br />engineering specification. <br /> OUT R COS <br />89 HSC 25290.1(j) 2060008 - Enhanced leak detection testing performed before the tank is placed in <br />use <br /> OUT R COS <br />90 CCR 2666(b)(2) 2060029 - SW piping has been upgraded to continuously monitored DW piping <br />when replacement or repair needed <br /> OUT R COS <br />91 HSC 25291(e) 2010 - Administration/Documentation - General OUT R COS <br />92 - 2015 - Administrative/Documentation - General Local Ordinance OUT R COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item #Remarks <br />14 CCR 2637.2(d&e), 2665(a&b) 2010018 - Overfill prevention equipment inspection report form submitted to the UPA <br />within 30 days <br />OBSERVATION: An overfill prevention equipment inspection was performed on 8/28/2024 and a test report was <br />submitted on 10/2/2024, 5 days late. <br />REGULATION GUIDANCE: A copy of the test report must be submitted within 30 days of the tests. <br />CORRECTIVE ACTION: Take all necessary precautions to ensure testing and submittal of test reports are performed in <br />a timely manner. <br />This is a Repeat (Class 2) Violation. <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD <br />Page 4 of 6EHD - CUPA Inspection Report IS03 <br />CP22 - UST FULL <br />12/16/2025FA0002541 PR0231074 4589456