My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PESCADERO
>
1535
>
2800 - Aboveground Petroleum Storage Program
>
PR0515797
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/22/2025 11:59:20 AM
Creation date
5/22/2025 11:54:19 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0515797
PE
2833 - AST FAC 100 K + 1 - </=1 M GAL CUMULATIVE
FACILITY_ID
FA0003854
FACILITY_NAME
YRC INC
STREET_NUMBER
1535
Direction
E
STREET_NAME
PESCADERO
STREET_TYPE
AVE
City
Tracy
Zip
95304
APN
21306046
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1535 E Pescadero AVE Tracy 95304
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />AMENDED <br />4/11/2025 <br />CP22 - AST Non-Qualified Inspection Report <br />Date: <br />March 12, 2025 <br /> Facility Address: <br /> 1535 E Pescadero AVE, Tracy <br /> Facility Name: <br /> YRC INC <br /> □ OUT □ R □ COS4045 - Release/Leaks/Spills - General Local Ordinance 86 <br /> □ OUT □ R □ COS4050 - Abandonment/Illegal Disposal/Unauthorized Treatment - General See below 87 <br /> □ OUT □ R □ COS4055 - Abandonment/Illegal Disposal/Unauthorized Treatment - General Local Ordinance 88 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />Code of Fed Regulations 112.7(f)(3) 4020002 - Spill prevention briefings are conducted annually. <br />OBSERVATION: Failure to conduct spill prevention briefing for oil-handling personnel at least once a year to assure <br />adequate understanding of the SPCC Plan, including: 1. Known discharges or failures. 2. Malfunctioning components. <br />3. Any recently developed precautionary measures. <br />REGULATION GUIDANCE: (f)(3) Schedule and conduct discharge prevention briefings for your oil-handling personnel <br />at least once a year to assure adequate understanding of the SPCC Plan for that facility. Such briefings must highlight <br />and describe known discharges as described in § 112.1(b) or failures, malfunctioning components, and any recently <br />developed precautionary measures. <br />CORRECTIVE ACTION: Discharge prevention briefings for oil handling personnel must be scheduled and conducted at <br />least once a year to assure adequate understanding of the SPCC Plan for that facility. Conduct all required spill <br />prevention briefings. Provide compliance verification to the EHD. <br />This is (Minor) Violation. <br /> 32 <br />Code of Fed Regulations 112.8(c)(3)(iv) 4010026 - Records maintained of drainage from diked areas. <br />OBSERVATION: Adequate records of drainage of uncontaminated rainwater from diked areas (or NPDES permit <br />records) of drainage were not found on site. <br />REGULATION GUIDANCE: (c)(3)(iv) Keep adequate records of such events, for example, any records required under <br />permits issued in accordance with §§ 122.41(j)(2) and 122.41(m)(3) of this chapter. <br />CORRECTIVE ACTION: Immediately begin maintaining adequate records (or NPDES permit records) of drainage from <br />diked areas. Submit proof of correction to the EHD. <br />This is (Minor) Violation. <br /> 52 <br />Code of Fed Regulations 112.7(e), 112.8(c)(6) 4010021 - Written Inspection/testing procedures kept, inspection/testing <br />records signed, kept for 3 years. <br />OBSERVATION: The facility failed to keep written procedures and records of inspections and tests, including integrity <br />tests, for at least three years. Copies of inspection and testing records for 2024 and 2025 were not found on site. <br />REGULATION GUIDANCE: 112.7(e), Conduct inspections and tests required by this part in accordance with written <br />procedures that you or the certifying engineer develop for the facility. You must keep these written procedures and a <br />record of the inspections and tests, signed by the appropriate supervisor or inspector, with the SPCC Plan for a period <br />of three years. Records of inspections and tests kept under usual and customary business practices will suffice for <br />purposes of this paragraph. 112.8(c)(6) Test or inspect each aboveground container for integrity on a regular schedule <br />and whenever you make material repairs. <br />CORRECTIVE ACTION: Inspections and tests must be conducted in accordance with the written procedures <br />developed in the Spill Prevention, Control, and Countermeasure (SPCC) Plan. Records of these inspections and tests <br /> 57 <br />FA0003854 PR0515797 SC001 03/12/2025 <br />EHD Rev. 12/06/2021 CP22 - AST Non-Qualified OIRPage 5 of 6 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.