Laserfiche WebLink
Environmental Health Department <br />AMENDED <br />4/11/2025 <br />CP22 - AST Non-Qualified Inspection Report <br />Date: <br />March 12, 2025 <br /> Facility Address: <br /> 1535 E Pescadero AVE, Tracy <br /> Facility Name: <br /> YRC INC <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />must be signed by the appropriate supervisor or inspector and kept on-site with the SPCC Plan for three years. <br />Immediately locate a copy of all inspection and testing records for the last three years, maintain them on-site, and <br />submit copies to the EHD. <br />This is (Class 2) Violation. <br />Code of Fed Regulations 112.8(c)(8)(v) 4030022 - Liquid level sensing devices regularly tested to ensure proper <br />operation. <br />OBSERVATION: Liquid level sensing devices for the two 80,000 gallons aboveground storage tanks have not been <br />tested. The technician tested the "high-high" level sensing alarm, the alarm did not turn on. No alarm sound nor light <br />were observed. <br />REGULATION GUIDANCE: (c)(8)(v) You must regularly test liquid level sensing devices to ensure proper operation . <br />CORRECTIVE ACTION: Liquid level sensing devices must be installed in accordance with CFR 112.8 and shall be <br />regularly tested to ensure proper operation. Immediately conduct all necessary testing of all liquid level sensing <br />devices to ensure proper operation, submit test results to the EHD. <br />This is (Class 2) Violation. <br /> 61 <br />Overall Inspection Comments: <br />An inspection checklist was provided to the facility operator on the day of inspection. A complete report was <br />finished on 4/11/2025 and replaces the initial checklist. <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, within 30 days of receiving the complete inspection report. <br />Emailed to Ruben Byerley, <br />Environmental Contact <br />March 12, 2025 <br />(209) 616-3045Printed Name and Title: <br /> Date: Inspector: <br /> Kristina Saetern, EHS <br /> Inspector Phone: Received by: <br />AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING THIS <br />FACILITY BACK INTO COMPLIANCE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />FA0003854 PR0515797 SC001 03/12/2025 <br />EHD Rev. 12/06/2021 CP22 - AST Non-Qualified OIRPage 6 of 6 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD