Laserfiche WebLink
A dOAQU1N Environmental Health Department <br /> COUNTY <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> DIAMOND GAS&MARKET#10 515 W ELEVENTH ST TRACY i Uly 11 2025 <br /> 86 CA Code of Regulations 2060024-UST system is made of or lined with materials that are compatible with the substance ❑OUT ❑R ❑COS <br /> 2631.1,2660(m) stored. <br /> 87 CA Code of Regulations 2060021-Striker plate installed and positioned correctly. ❑OUT ❑R ❑COS <br /> 2631(c),2662(d) <br /> 88 CA Code of Regulations 2060007-Primary and secondary containment designed and constructed to an engineering ❑OUT ❑R ❑COS <br /> 2631(b&d),2666(b&e) specification. <br /> 89 CA Health and Safety 2060008-Enhanced leak detection testing performed before the tank is placed in use ❑OUT ❑R ❑COS <br /> Code 25290.10) <br /> 90 CA Code of Regulations 2060029-SW piping has been upgraded to continuously monitored DW piping when replacement ❑OUT ❑R ❑COS <br /> 2666(b)(2) or repair needed <br /> 91 CA Health and Safety 2010-Administration/Documentation-General ❑OUT ❑R ❑COS <br /> Code 25291(e) <br /> 92 2015-Administrative/Documentation-General Local Ordinance ❑OUT ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 4 CA Code of Regulations 2632(d)(2), 2634(e)2010014- Facility has submitted a complete and accurate UST Response <br /> Plan.. <br /> OBSERVATION:The response plan is not current and/or not approved by the EHD. Section 5"Monitoring Indicators" <br /> was not completed. <br /> REGULATION GUIDANCE:The response plan must be uploaded to the California Environmental Reporting System <br /> (CERS). <br /> CORRECTIVE ACTION: Immediately log into CERS, upload the completed form, and submit for review by the EHD. <br /> This is a repeat violation (Class 2) Violation. <br /> 24 CA Code of Regulations 2632(c), 2634(d), 2636(f)2030003- Leak detection system maintains continuous monitoring <br /> that activates an audible and visual alarm. <br /> OBSERVATION:The sensor on dispenser 1/2 was on its side. The sensor would fail to activate an audible and visual <br /> alarm when tested to ensure continuous monitoring of the tank system. <br /> REGULATION GUIDANCE:All monitoring equipment shall be maintained to activate an audible and visual alarm or <br /> stop the flow of product at the dispenser when it detects a leak. <br /> CORRECTIVE ACTION: The inspector repositioned the sensor at the time of inspection. <br /> This was corrected on site. <br /> This is a repeat violation (Class 2) Violation. <br /> 30 CA Code of Regulations 2630(d), 2641(a)2060015-Leak detection equipment located so leak is detected at the <br /> earliest possible opportunity(TCR 9d). <br /> OBSERVATION:The sensor on dispenser 5/6 was raised approximately 7 inches off the lowest point of the sump and <br /> not located to detect a leak at the earliest opportunity. <br /> REGULATION GUIDANCE: Monitoring equipment shall be maintained to be able to detect a leak at the earliest <br /> possible opportunity. <br /> FA0003539 PR0231400 SCO01 07/11/2025 <br /> EHD Rev.12/06/2021 Page 5 of 8 CP22-UST FULL OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />