Laserfiche WebLink
A dOAQU1N Environmental Health Department <br /> COUNTY <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> DIAMOND GAS&MARKET#10 515 W ELEVENTH ST, TRACY i Uly 11 2025 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> CORRECTIVE ACTION: Ensure that a written response documenting corrective actions taken or proposed is <br /> submitted within 30 days of receiving an inspection report. <br /> This is a repeat violation (Class 2) Violation. <br /> 85 CA Code of Regulations 2631(a); HSC 25290.1(c)2060027-Tank system primary containment is constructed, <br /> operated, and maintained product-tight.. <br /> OBSERVATION: Fuel was pooling inside the UDC 1/2 sump, and a strong fuel odor was present, indicating a leak in <br /> the primary containment. <br /> REGULATION GUIDANCE:All primary containment for the UST system must be product tight. <br /> CORRECTIVE ACTION: Immediately have a properly licensed, trained, and certified contractor repair or replace the <br /> failed component(s), under permit and inspection of the EHD if necessary. <br /> This is a repeat violation (Class 2) Violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by August 13, 2025. <br /> To minimize person to person, contact EHD is choosing to write the name of person receiving the report instead <br /> of having them sign. Starting July 1,2025, all in-office CERS help will be provided at EHD hourly rate ($179). To <br /> schedule an appointment, please call (209)468-3420. <br /> Note: <br /> The monitoring plan for all 3 tanks lists incorrect UDC panel information. UDC sensors are not connected to the <br /> panel. <br /> UST Tank forms did not identify which grade of Biodiesel, B20 was observed on site. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING THIS <br /> FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: July 11,2025 Inspector: Inspector Phone: <br /> Printed Name and Title: Monica De Anda, EHS (209)616-3063 <br /> Mike Omar, Owner <br /> FA0003539 PR0231400 SCO01 07/11/2025 <br /> EHD Rev.12/06/2021 Page 8 of 8 CP22-UST FULL OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />