Laserfiche WebLink
SAW dOAQUI <br />COUNT <br />Environmental Health Department <br />EHD Rev. 12/06/2021 <br />FA0023065 PRO540345 SCO01 06/30/2025 <br />Page 5 of 9 CP22 - UST FULL OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />CP22 - UST FULL Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />FedEx Ground - Tracy <br />5655 Hood WAY Tracy <br />June 30 2025 <br />85 <br />CA Code of Regulations <br />2060027 - Tank system primary containment is constructed, operated, and maintained <br />❑ OUT <br />❑ R ❑ COS <br />2631(a); HSC <br />product -tight. <br />25290.1(c) <br />86 <br />CA Code of Regulations <br />2060024 - UST system is made of or lined with materials that are compatible with the substance <br />❑ OUT <br />❑ R ❑ COS <br />2631.1, 2660(m) <br />stored. <br />87 <br />CA Code of Regulations <br />2060021 - Striker plate installed and positioned correctly. <br />❑ OUT <br />❑ R ❑ COS <br />2631(c), 2662(d) <br />88 <br />CA Code of Regulations <br />2060007 - Primary and secondary containment designed and constructed to an engineering <br />❑ OUT <br />❑ R ❑ COS <br />2631(b&d), 2666(b&e) <br />specification. <br />89 <br />CA Health and Safety <br />2060008 - Enhanced leak detection testing performed before the tank is placed in use <br />❑ OUT <br />❑ R ❑ COS <br />Code 25290.10) <br />90 <br />CA Code of Regulations <br />2060029 - SW piping has been upgraded to continuously monitored DW piping when replacement <br />❑ OUT <br />❑ R ❑ COS <br />2666(b)(2) <br />or repair needed <br />91 <br />CA Health and Safety <br />2010 - Administration/Documentation - General <br />❑ OUT <br />❑ R ❑ COS <br />Code 25291(e) <br />92 <br />2015 - Administrative/Documentation - General Local Ordinance <br />❑ OUT <br />❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />24 <br />CA Code of Regulations 2632(c), 2634(d), 2636(f) 2030003 - Leak detection system maintains continuous monitoring <br />that activates an audible and visual alarm. <br />OBSERVATION: The L28 Bio Fill Brine sensor (bio diesel) failed to activate an audible and visual alarm when tested to <br />ensure continuous monitoring of the tank system. <br />REGULATION GUIDANCE: All monitoring equipment shall be maintained to activate an audible and visual alarm or <br />stop the flow of product at the dispenser when it detects a leak. <br />CORRECTIVE ACTION: Correct immediately by having a properly licensed, trained, and certified contractor replace <br />the failed component with a functional component (LG 113-x listed, if applicable), and obtain a permit within one <br />business day from the EHD, if needed. If the failed component can't be replaced immediately, there is a possibility <br />that the biodiesel UST system may be red tagged to prevent fuel inputs. <br />This is (Class 2) Violation. <br />35 <br />CA Health and Safety Code 25290.1(e) 2030065 - Interstitial space of the UST is under constant VPH monitoring (TCR <br />9d). <br />OBSERVATION: The L28 Bio Fill Brine (biodiesel) sensor failed when tested. <br />REGULATION GUIDANCE: The interstitial space of the UST shall be maintained, as designed, under constant vacuum <br />or pressure such that a breach in the primary or secondary containment is detected before the hazardous substance <br />is released into the environment. <br />CORRECTIVE ACTION: Correct immediately by having a properly licensed, trained, and certified contractor replace <br />the failed component with a functional component (LG 113-x listed, if applicable), and obtain a permit within one <br />business day from the EHD, if needed. If the failed component can't be replaced immediately, there is a possibility <br />that the biodiesel UST system may be red tagged to prevent fuel inputs. <br />This is a repeat violation (Class 2) Violation. <br />36 <br />CA Health and Safety Code 25290.1(d) 2060023 - System has a mon system that can detect entry of haz sub <br />EHD Rev. 12/06/2021 <br />FA0023065 PRO540345 SCO01 06/30/2025 <br />Page 5 of 9 CP22 - UST FULL OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />