My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU-2500667
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3950
>
2600 - Land Use Program
>
SU-2500667
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/17/2025 3:50:48 PM
Creation date
7/3/2025 7:44:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU-2500667
PE
2634 -ZONING COMPLIANCE REVIEW - MINOR (Z)
STREET_NUMBER
3950
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
10118032
CURRENT_STATUS
Closed - Issued
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
3950 E WATERLOO RD STOCKTON 95215
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FIXED END General Notes - Reflected Ceiling Plan jmw_ � _ � <br /> • • • OM PERIMETER R'e�ER 3/A2.2 <br /> p <br /> z 1. SUSPEND CEILINGS IN STRUCTURES SHALL BE DESIGNED AND INSTALLED IN 713 washingtonstreet <br /> UJ ACCORDANCE WITH ASTM C535, ASTM C635, AND THE CISCA FOR SEISMIC ZONES 3-4. kerrville, <br /> texas 78028 <br /> MAX <br /> DIAO PRAGINC WIRE AND 830.890.8808/830 :• 0 <br /> _ COMPRESSION STRUfi TYPICAL, 2. A HEAVY TYPE"T-BAR"CEILING SYSTEM SHALL BE USED. <br /> LL_ REl`ER -4/A2.1 <br /> Sacramento,ca.916.980.9165 <br /> 40 40 4 0 3. THE WIDTH OF PERIMETER CLOSURE SHALL BE 2 INCHES MINIMUM IN WIDTH. jmwellsdesign@gmail.com/ <br /> lackmwells@outlook.com <br /> 2 CSA. \/ERTIGAL HANGER WIRE COPY RIGHT 2 0 2 4 <br /> Afi 4'-O O.O. AT MAIN RUNNER _ 4. IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE END OF CEILING GRID SHALL BE <br /> MINIMUM 5 TIGHT TURNS IN 1 1/2" ATTACHED TO THE CLOSURE ANGLE. THE OTHER END IN EACH HORIZONTAL DIRECTION NOT PUBLISHED.ALL RIGHTS RESERVED BY DESIGNER. DRAWINGS <br /> AND SPECIFICATIONS AS INSTRUMENTS OF SERVICE ARE AND SHALL <br /> DOTH ENDS, RE1°ER 5/A2.2 SHALL HAVE A MINIMUM 0.75 INCH CLEARANCE FROM THE WALL END AND SHALL REST UPON ON OT ER PRO CTS ORERTY EX THE DESIGNER. HIS PROJECT ALL <br /> EXCEPT BY ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT EXCEPT BY <br /> OH APPROPRIATE COMPENSATION TO <br /> AND BE FREE TO SLIDE ON THE CLOSURE ANGLE. THE DESIGNER.CONTRACTOR ISAGREEMENT IN W ITING AND T RESPONSIBLE FOR CONFIRMING AND <br /> N CORRELATION DIMENSIONS AT THE JOB SITE,THE DESIGNER WILL NOT <br /> r BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, <br /> 5. FOR CEILING AREA EXCEEDING 1,000 SQUARE FEET, HORIZONTAL RESTRAINS OF THE PROGR1AMSNCON CONNECTION WITH THQUENCES OR OE PROJECT. <br /> R SAFETY PRECAUTIONS AND <br /> CEILING TO THE STRUCTURE SYSTEM SHALL BE PROVIDED. THE TRIBUTARY AREAS OF THE <br /> 0- GROSS TEES HORIZONTAL RESTRAINS SHALL BE APPROXIMATELY EQUAL. pI&AC"W309311111W <br /> 6. FOR CEILING AREAS EXCEEDING 2,500 SQUARE FEET, A SEISMIC SEPARATION JOINT OF Company, LLC <br /> FULL HEIGHT PARTITION THE BREAKS THE CEILING SYSTEM INTO AREAS NOT EXCEEDING 2,500 Daryl Jordan,P.E. <br /> 1k 40 41 40 40 40 PO Box 467 <br /> MAIN RUNNERS i S.F. SHALL BE PROVIDED UNLESS STRUCTURAL ANALYSIS ARE PREFORMED ON THE CEILING Mount Hermon,CA 95941 <br /> BRACING SYSTEM FOR THE PRESCRIBED SEISMIC FORCES THAT DEMONSTRATES CEILING (209) 485-8620 <br /> SYSTEM PENETRATIONS AND CLOSURE ANGLES PROVIDE SUFFICIENT CLEARANCE TO <br /> 4'-0" 12'-0" i ACCOMMODATE THE ANTICIPATED LATERAL DISPLACEMENT. �pEESSIpIt <br /> 0,9���` •• <br /> ® O 6.1 THE SMALLER, BROKEN-UP AREAS SHALL COMPLY WITH ITEMS 5, 4 AND 5 <br /> ll C-)0 LJ <br /> rI <br /> 10 uy 7. SPRINKLER HEADS AND OTHER SIMILAR TYPE OF PENETRATIONS THAT DO NOT BEHAVE �` <br /> INTEGRALLY WITH THIS CEILING SYSTEM IN THE LATERAL DIRECTION, SHALL HAVE A 2 INCH *`` 'O <br /> LL i OVER SIZE RING, SLEEVE OR ADAPTOR THRU THE CEILING TILE WHICH SHALL ALLOW FOR THE �e CIVIC ��\P <br /> MOVEMENT OF AT LEAST 1 INCH IN ALL DIRECTIONS. Q If CAL\� <br /> I I I <br /> FREE END I i 7.1 EXCEPT WHERE RIGID BRACES ARE USED TO LIMIT LATERAL DEFLECTIONS. <br /> Diagrammatic Ceiling <br /> 02 I I 7.2 AS AN ALTERNATIVE SWING JOINT ACCOMMODATING AN INCH OF CEILING date of issue/revisions: <br /> NTS __________________�_ MOVEMENT IN ALL DIRECTIONS MAY BE USED AT THE SPRINKLER HEAD EXTENSION. <br /> ---------------------------7 no. date description <br /> I I <br /> OIL <br /> E3.0. (E) Wd FIr I i 8 CHANGES IN PLAN ELEVATIONS SHALL BE PROVIDED WITH POSITIVE BRACING. <br /> Sys. I i II <br /> Eye Screw I i 9 CABLE TRAYS AND ELECTRICAL CONDUITS SHALL BE SUPPORTED INDEPENDENTLY OF <br /> THE CEILING. <br /> 14 Oa. x 5/4'' <br /> Wide Ceiling I 10 A STRUT IS TO BE ATTACHED TO THE SUSPENSION SYSTEM AND TO THE STRUCTURE ABOVE <br /> Face of Glip I i AT EACH BRACE. <br /> Interior Wall <br /> for 5ulkhead 11 ATTACHMENT OF THE BRACING WIRES TO THE MAIN BEAM AND THE STRUCTURE SHOULD <br /> SUPPORT THE GREATER 200# OR THE ACTUAL DESIGN LOAD WITH A SAFETY FACTOR OF 2. <br /> I I O I <br /> I <br /> 12 Oa. Vertical P P 12 IF PARTITIONS ARE ATTACHED TO THE SUSPENSION SYSTEM, THEY MUST BE LATERALLY <br /> ;IO° Max. Hanger Wire y <br /> BRACED TO THE BUILDING STRUCTURE. <br /> I <br /> I <br /> 13 LIGHT FIXTURES: <br /> I 13.1 PENDENT MOUNTED FIXTURES MUST BE SUPPORTED FROM THE STRUCTURE. THEY MAY <br /> 8" Max i <br /> Stabalizer Bar to Keep NOT USE THE CEILING SUSPENSION SYSTEM FOR SUPPORT. <br /> I <br /> Perimeter Components 13.2 MUST BE POSITIVELY ATTACHED TO WITHSTAND 100% OF THE FIXTURE WEIGHT. <br /> from Spreading Apart <br /> MID <br /> 5/4" Min Heavy Duty I I _�_ - 13.3 THERE MUST BE TWO 12-GA. WIRES ATTACHED AT DIAG CORNERS. IF THE FIXTURE IS 58# tv <br /> Suspended I I i OR LESS. IF THE FIXTURE IS MORE THAN 58#, FIXTURE MUST BE INDEPENDENTLY SUPPORTED <br /> T�Par System <br /> I= FROM THE BUILDING STRUCTURE. O <br /> o - - <br /> o � I <br /> MEP Symbols Legend C <br /> I <br /> d p0 <br /> 2" Perimeter Molding <br /> 110v Receptacle $ Dimmer Light Switch •� O <br /> (Restrained) <br /> I a Ceiling Fan � IIIIIIIIIIIIIIIIIIIIII� <br /> 110v GFI Receptacle L <br /> Pop Rivet Rewired @ Two - -� - i� gfi $ Automatic Light Switch <br /> Adjacent Walls `� <br /> 110v Water resistant <br /> Wpgfl GFI Receptacle $m Motion Light Switch V <br /> LAY- IN CEILING AT PERIMETER WALL , 110v Receptacle"##" f Q <br /> NTS 0 _ __ __ __ _ _ Indicates inches AFF Fan Switch <br /> 03 7� I i -- -Y--L-, T I <br /> 110v Quad Receptacle `"p cc <br /> Water resistant Switch Ceiling Fan w/Light <br /> 0 <br /> ® Fixture O W <br /> , I Ili 110v Floor Receptacle <br /> O Push Button Switch O .c <br /> ® 110v Quad Floor L <br /> Receptacle +� % <br /> � Pott. of ', I i � i � Door Sensor ,____ � � •� <br /> _ Structure I > 220v Receptacle V <br /> ` ` type �/ Volume Control Switch Leg to H c <br /> Junction Box C <br /> LV .Y <br /> r db Door Bell •� C v <br /> Spring Cli I T� Ln <br /> 12 Oa. Splay <br /> Junction Box weather Gas Valve per Local <br /> � Compression wire p y - p resistant dchm Door Chime gas/#"and State Codes •� eh H <br /> Secured to I Q Q <br /> 12 Ga. Strut Structure I Scheduled Lighting <br /> ' Z Fixture <br /> Hanger WirI Phone Jack <br /> e <br /> Wall Sconce � T Thermostat ^y <br /> N <br /> O <br /> 00 Gross T o0 0 0 I Recessed Can Fixture TV TV Jack/Cable ' <br /> i or O or� 9 Supply Air Diffuser <br /> 0 o a o Main Tee <br /> I I Ian Local Area Network <br /> 3 0 o O I R/A Return Air <br /> C) Q O J Pendant Lighting Fixture <br /> ------------------------------------ -----------------------------a �J <br /> N I Audio Speaker \ <br /> Z I Exhaust Fan Z U <br /> 0 0 "Wet Area" Recessed <br /> Z p Can Fixture Z <br /> 0 Oam <br /> Fed "Eyeball" Camera — Supply Air Duct <br /> Fixture �eturn Air DuctCOMPRESSI N STRUT/SPLAY WIRES <br /> 004 A/V Location <br /> A <br /> NTS o[� <br /> www <br /> Exterior Security/ Flood z r <br /> 0 Fixture WiFi AP N o <br /> U oco <br /> 1603.1.5 Earthquake design data.The following information o Iwo _ ~ EI- rq <br /> CD CabinetLED related to seismic loads shall be shown,regardless I — — — (LED) W p � M o0 <br /> of whether seismic loads govern the design of the lateral Lighting Smoke Detector-All smoke w oM a <br /> cy-) May Pe force-resisting system of the structure: sd dectors to be interconnected I' 0 O 0 0 <br /> 1. Risk category.-� ry with battery backu Slack Fluorescent Fixture p <br /> 2. Seismic importance factor,le. #x#Fluor ("#x#" size) <br /> 3. Mapped spectral response acceleration parameters, OCarbon Monoxide Detector s h e e t c o n t e n t s <br /> D Ss and Si. ------------------ Cd <br /> / - Li ht Fixture <br /> Z g 4. Site class. Proposed <br /> 5. Design spectral response acceleration parameters, 0== Tract Lighting n Smoke Detector/Carbon Floor PIan <br /> SDs and SDI. <br /> U 6. Seismic design category. <br /> sd cd monoxide detector <br /> 7. Basic seismic force-resisting system(s). <br /> Seismic GI $ <br /> 8. Design base shear(s). PLAN Light Switch <br /> Z 9. Seismic response coefficient(s),Cs. NORTH Z Exhaust Fan <br /> Q 10. Response modification coefficient(s),R. $ 3 Way Light Switch project no <br /> U 11.Analysis procedure used. 3 24101 <br /> y p Electrical Panel drawn by <br /> LU x I/4" <br /> LU i� Afi=PROXIMATE jm <br /> J S.M.S. NORTH 4 Way L'Ight Switch checked by <br /> 0 Reflected Ceiling PlanZ JMW/DJ project architect - <br /> Q 1/4 <br /> " 1'-0 <br /> = <br /> I� 3 flee <br /> plot date09162024 <br /> � O sheet number <br /> 0 MEP DISCLAIMER: <br /> JMWELLS DESIGN is not a engineering firm. The mepdesign/system and and/or elements, either noted or implied,are foreg neral <br /> guideline purposes only. These drawings have not been reviewed by a licensed Engineer, (unless an official stamp of an licensed <br /> LAY- IN FIXTURE RESTRAINT engineer appears on these drawings). it is the responsibility of the owner and General Contractor to obtain the services of a licensed A590 <br /> n oEngineer to review these drawings prior to construction. By accepting these drawings,JMWELLS Designer/Jack Wells is released from <br /> 05 all liability for any MEP defects and/or failures. <br /> D NTS - Of - <br />
The URL can be used to link to this page
Your browser does not support the video tag.