Foundation Schematic Notes jmw_ _ <br /> sign <br /> O GENERAL: 713 washington street <br /> 1. THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND DETAILS BEFORE kerrville,texas80 <br /> M CONSTRUCTION AND REPORT ANY DISCREPANCIES OR DISCREPANCIES OR OMISSIONS IN 830.890.8808/831 :• 1 <br /> THE CONTRACT DOCUMENTS TO THE STRUCTURAL ENGINEER. Sacramento,ca.916.980.9165 <br /> 0) ILA <br /> 2. THE CONTRACTOR SHALL COORDINATE ALL LEAVE-OUTS, SLEEVES AND OTHER SLAB jmwellsdesign@gmail.com/ <br /> tl-I Interior z Exterior Interior <br /> PENETRATIONS BEFORE CONSTRUCTION. jackmwells@outlook.com <br /> 71 LU <br /> COPY RIGHT 2 0 24 <br /> LU 3. SITE, SUBGRADE, CONCRETE, AND CURING SHALL CONFORM TO THE PROVISIONS OF ACI NOT PUBLISHED.ALL RIGHTS RESERVED BY DESIGNER. DRAWINGS <br /> ® O 302.1 R-80. GUIDE FOR CONCRETE FLOOR AND SLAB CONSTRUCTION. IF UNUSUAL AND SPECIFICATIONS AS INSTRUMENTS OF SERVICE ARE AND SHALL <br /> REMAIN THE PROPERTY OF THE DESIGNER.THEY SHALL NOT BE USED <br /> (X -t AMOUNTS OF WATER CONTINUE TO APPEAR ON SITE, A SOILS ENGINEER SHALL BE ON OTHER PRO JECTSOREXTENSIONS TOTHIS PROJECT EXCEPT BY <br /> AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO <br /> ® O r!�! CONTACTED FOR CORRECTIVE ACTIONS. THE DESIGNER.CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND <br /> -A IYl CORRELATION DIMENSIONS AT THE JOB SITE,THE DESIGNER WILL NOT <br /> -A BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, <br /> O 4. SITE GRADING AND DRAINAGE AROUND THE FOUNDATION SHALL BE MAINTAINED AT ALL TECHNIQUES, SEQUENCES OR FOR SAFETY PRECAUTIONS AND <br /> d TIMES IN SUCH A MANNER THAT THE SURFACE OR GROUND WATER WILL NOT COLLECT PROGRAMS IN CONNECTION WITH THE PROJECT. <br /> O AROUND OR UNDER THE SLAB. THIS IS CRITICALLY IMPORTANT DURING THE PERIOD Pg�����3T <br /> IMMEDIATELY AFTER THE CONCRETE PLACEMENT. <br /> Exterior 50 BAR ®IAMEfiERS 5. IF TREES AND HIGH DENSITY BRUSH ARE REMOVED, CONTRACTOR SHALL FOLLOW GUIDE Company, LLC <br /> LINES FOR PAD PREPARATION OUTLINED BY SOILS ENGINEER. TREES WHOSE CANOPY Daryl Jordan P.E. <br /> * 2'-0 MIN. EXTEND OVER SLAB ARE NOT ADVISED SINCE ROOT SYSTEMS CAN EXTEND UNDER THE PO Box 467 <br /> A4.0 SLAB, WHICH IS NOT ADVISED. Mount Hermon,CA 95941 <br /> (209) 485-8620 <br /> 6. THERE SHALL BE A MINIMUM OF 6 INCHES OF CLEARANCE BETWEEN THE TOP OF SLAB OR <br /> NOTE: ALL CORNER BARS SHALL BRICK LEDGE AND SOIL SURFACE. ��`�QO <br /> -j\- JO ••• <br /> BE SAME SIZE AND SPACING AS 7. CONSTRUCTION JOINTS ARE NOT PERMITTED UNLESS SHOWN. = o <br /> � HORIZONTAL REINFORCEMENT. � <br /> \ I 8. TRENCHES FOR PLUMBING LINES SHALL NOT BE LOCATED DIRECTLY UNDER BEAMS. _J <br /> + I z LOCATE BETWEEN BEAMS AND CROSS AT RIGHT ANGLES UNDER BEAM. * o <br /> 9. WHERE THERE ARE DISCREPANCIES BETWEEN SLAB DIMENSIONS AND ARCHITECTURAL CIVIL <br /> 2-0 v PLANS,THE ARCHITECTURAL PLANS SHALL CONTROL. F0 CAS <br /> l� CIAInterior Interior 0 <br /> S1 <br /> SUGGEST 3 10. UPON COMPLETION OF FINAL GRADING, ALL BEAMS SHALL HAVE A MINIMUM SOIL <br /> .0 I AT 16" O.C. EACH WAY) COVER OF 6 INCHES. <br /> I O <br /> m 2 1/2"X 3 1/2" REBAR BAR LIFT/ 11. IT IS ADVISABLE TO HAVE THE HOMEOWNER OR A REPRESENTATIVE OF THE BUILDER date of issue/revisions: <br /> O O CHAIR OR EQUAL AT 36" O.C. MAX PRESENT DURING THE FOUNDATION PLACEMENT. <br /> I <br /> L_____J_ no. date description <br /> CODE&DESIGN SPECIFICATIONS: <br /> IA <br /> �Ajl IN I I <br /> GENERAL: 2022 CALIFORNIA BUILDING AND RESIDENTIAL CODE IS USED AS THE BASIC CODE <br /> Exterior DOCUMENT. THIS IS SUPPLEMENTED BY THE FOLLOWING SPECIFICATIONS AND REFERENCES TO <br /> 50 5AR DIAMETERS SO BAR DIAMETERS a) BE USED FOR DESIGN, DETAILING AND CONSTRUCTION. <br /> 2'-0 MIN. 2'-0 MIN. A. STRUCTURAL CONCRETE: 2022 BUILDING CODE FOR REINFORCED CONCRETE OF THE <br /> SLAB/ FOUNDATION NOTE: MIN 5" THK. SLAB CONSISTING <br /> OF 3500 PSI CONCRETE REINF. w/ #3 AT 16" O.G. E.W. AMERICAN CONCRETE INSTITUTE (ACI 318-19). <br /> OVER IO mil MOISTURE BARRIER/ 4" AGGREGATE BASE B. SPECIFICATION FOR STRUCTURAL CONCRETE FOR BUILDINGS, ACI 301-84, AMERICAN <br /> AND COMP'D SELECT FILL AND/OR UNDISTURBED SOIL. CONCRETE INSTITUTE. <br /> GRADE BEAMS SHALL BE MIN 12"w x 24" d, REINFORCED TYPICAL CORNER BAR SLAB REINFORCEMENT <br /> w/ MIN 2- #5 TOP AND BOT. C. CONTROL OF CRACKING IN CONCRETE STRUCTURES, ACI 224R-80, AMERICAN <br /> 01 PLACEMENT DETAIL 02 PLACEMENT DETAIL <br /> CONCRETE INSTITUTE. <br /> %2" <br />