General Notes - PLUMBING jmwelisd _
<br /> sign
<br /> 1. ALL WORK SHALL CONFORM TO THE UNIFORM PLUMBING CODE, LOCAL CODES, INCLUDING 713 Washington street
<br /> INSTALLATION OF ALL REQUIRED CLEANOUTS kerrville,texas 78028
<br /> 2. VERIFY SIZE, DEPTH, LOCATION AND ADEQUACY OF ALL UTILITIES, INCLUDING METER LOCATIONS AND "0' '
<br /> 95.9770
<br /> SEWER INVERTS. Sacramento,ca.916.980.9165
<br /> 3. BEFORE STARTING WORK ALL PIPING IN FINISHED AREAS SHALL BE CONCEALED WHERE POSSIBLE, AND jmwellsdesign@gmail.com/
<br /> EXPOSED PIPING SHALL BE RUN AS HIGH AS POSSIBLE AND TIGHT TO WALLS. jackmwells@outlook.com
<br /> COPY RIGHT 2 0 24
<br /> 4. ALL LINES TO BE AWAY FROM BEARING FOOTINGS,OR AS DIRECTED BY STRUCTURAL ENGINEER. NOT PUBLISHED.ALL RIGHTS RESERVED BY DESIGNER. DRAWINGS
<br /> AND SPECIFICATIONS AS INSTRUMENTS OF SERVICE ARE AND SHALL
<br /> REMAIN THE PROPERTY OF THE DESIGNER.THEY SHALL NOT BE USED
<br /> 5. INSTALL BACK FLOW PROTECTION DEVICES AS REQUIRED BY LOCAL CODE. ON OTHER PROJECTS OR EXTENSION$TO THIS PROJECT EXCEPT BY
<br /> AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO
<br /> THE DESIGNER.CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND
<br /> OT
<br /> 6. INSTALL PRESSURE REDUCING VALVE(S)WITH SHUT-OFF WHERE CITY PRESSURE EXCEEDS 80 PSI. CORRELATION DIMENSIONS AT THECONSTJOB RUCTION
<br /> THE DESIGNER ETL DS,
<br /> BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS,
<br /> TECHNIQUES, SEQUENCES OR FOR SAFETY PRECAUTIONS AND
<br /> PROGRAMS IN CONNECTION WITH THE PROJECT.
<br /> 7. ALL APPLIANCE AND PLUMBING VENTS SHALL BE AT LEAST TEN (10) FEET IN HORIZONTAL DIRECTION OR
<br /> THREE(3) FEET ABOVE THE OUTSIDE AIR INTAKES FOR HVAC UNITS. 3RAW110"WIME&W
<br /> 8• SEWER TO BE RUN AT 1/4"SLOPE, UPC (2019 CPC) SEC 718.1 LARGER MAY BE LAID AT A SLOPE OF NOT Company, LLC
<br /> Daryl LESS THAN 1%WHEN FIRST APPROVED BY THE BUILDING DEPARTMENT. y
<br /> 1 Jordan,P.E.
<br /> 9. ALL REQUIRED CLEANOUTS SHALL BE INSTALLED AS PER UPC (2019 CPC.)SEC 707 AND 719. CLEANOUTS PO Box 467
<br /> SHALL BE PLACED INSIDE THE BUILDING NEAR THE CONNECTION BETWEEN THE BUILDING DRAIN AND THE Mount Hermon,CA 95941
<br /> BUILDING SEWER OR INSTALLED OUTSIDE THE BUILDING AT THE LOWER END OF THE BUILDING DRAIN AND (209) 485-8620
<br /> EXTENDED TO GRADE.
<br /> �pF ESSIO
<br /> 01 10. ALL EXTERIOR HOSE BIBS SHALL BE PROVIDE WITH NON REMOVABLE BACK FLOW PREVENTION DEVICES. �OOP��� X019 �F •�'
<br /> -1116, 11. GAS PIPING SHALL NOT INSTALLED IN OR ON THE GROUND UNDER THE BUILDING.CPC SEC 1211.3 J
<br /> A4.0 12. PROVIDE BONDING FROM COLD TO HOT WATER PIPING TO COMPLY WITH NEC ART.250-104
<br /> * • �` o
<br /> 13. WATER CLOSETS SHALL BE TYPE WHICH USES 1.25 GALLONS PER FLUSH AND URINALS SHALL BE NOT MORE
<br /> THAN 1.25 GALLON PER FLUSH. SEC 1921.3(8)STATE HEALTH AND SAFETY CODE. CIV1�
<br /> ��� FOF CA��Ep�
<br /> 14. PROVIDE AN ADEQUATE AMOUNT OF HOT WATER, 120 DEGREES F MAX,AT LAVS.,IN ADDITION TO COLD
<br /> I i
<br /> WATER.
<br /> 15. ALL PLUMBING FIXTURES AND PIPING ARE TO BE LISTED BY AN APPROVED LISTING AND TESTING AGENCY date of issue/revisions:
<br /> AND PROPERLY LABELED. CPC SEC 301.1.1
<br /> 16. MATERIALS: no. date description
<br /> I i
<br /> I i
<br /> I i
<br /> A. ALL DRAINAGE PIPING AND FITTINGS SHALL BE CAST-IRON, GALVANIZED STEEL, GALVANIZED
<br /> I i
<br /> WROUGHT IRON, LEAD, COPPER, BRASS OR OTHER APPROVED MATERIALS HAVING A SMOOTH
<br /> AND UNIFORM BORE. (NO PLASTIC VENTING ALLOWED).CPC 701.1
<br /> B. ALL DRAINAGE FITTINGS SHALL BE COMPATIBLE WITH TYPE OF PIPE USED HAVING A INTERIOR
<br /> it WATERWAY SMOOTH AND OF THE SAME DIAMETER AS THE PIPING SERVED. CPC 701.2 DRAINAGE
<br /> AND VENTING SYSTEMS SHALL BE TESTED WITH A 10 FOOT HEAD OF WATER.
<br /> j C. NO FITTING, FIXTURE AND PIPING CONNECTION, DEVICE OR METHOD OF INSTALLATION WHICH
<br /> OBSTRUCTS OR RETARDS THE NORMAL FLOW OF WATER, SEWAGE OF AIR IN A DRAINAGE OR
<br /> VENTING SYSTEM SHALL BE USED.
<br /> D. NO GALVANIZED WROUGHT IRON OR GALVANIZED STEEL PIPE SHALL BE USED UNDERGROUND AND
<br /> 1 SHALL BE KEPT AT LEAST 6 INCHES ABOVE GROUND. CPC 701.1.1
<br /> E. COPPER TUBE FOR UNDERGROUND DRAINAGE AND VENT PIPING SHALL HAVE A WEIGHT OF NOT
<br /> I
<br /> LESS THAN THAT OF COPPER DRAINAGE TUBE TYPE DWV. CPC 701.1.4.THIS MEANS COPPER TUBING
<br /> TYPES K,L AND M WOULD BE ACCEPTABLE.
<br /> F. COPPER TUBE FOR ABOVE GROUND DRAINAGE AND VENT PIPING SHALL HAVE WEIGHT OF NOT
<br /> LESS THAN THAT OF COPPER DRAINAGE TUBE TYPE DWV CPC 701.1.4
<br /> G. ALL WATER PIPING AND FITTINGS SHALL BE OF BRASS, COPPER, GALVANIZED MALLEABLE IRON,
<br /> GALVANIZED STEEL OR OTHER APPROVED MATERIALS. CPC 604.4
<br /> H. COPPER TUBE FOR ABOVE OR UNDERGROUND WATER PIPING SHALL HAVE A WEIGHT OF NOT LESS
<br /> THAN TYPE 1". CPC 604.0 EXCEPTION: TYPE"M" MAY BE USED FOR WATER PIPING WHEN
<br /> INSTALLED ABOVE GROUND IN, OR ON, A BUILDING OR UNDERGROUND OUTSIDE OF BUILDINGS.
<br /> CPC 604.2
<br /> I j 1 j I• CAST IRON FITTINGS UP TO 2 INCH IN SIZE, WHEN USED IN CONNECTION WITH POTABLE WATER
<br /> PIPING SHALL BE GALVANIZED. CPC 604.1 AND 601.5
<br /> = J. ALL MALLEABLE IRON WATER FITTINGS SHALL BE GALVANIZED.
<br /> I I K. WATER LINES SHALL NOT BE EMBEDDED IN CONCRETE. CPC 313.1 O
<br /> -- - L. WRAP WATER PIPES PASSING THROUGH CONCRETE. CPC 313.1
<br /> M. WATER PIPING SYSTEM TESTING: 50 PSI OF AIR PRESSURE AND WITHSTAND TEST WITHOUT LEAKING A/
<br /> �r FOR AT LEAST 15 MINUTES. CPC 609.4 �j�
<br /> I WATER SUPPLY FIXTURE UNITS: rO
<br /> I MOP SINK 1 3.0
<br /> o
<br /> KITCHEN SINK 1 1.5 O
<br /> I SHOWER 1 2.0 }i
<br /> j CLOTHES WASHER 1 4.0 L
<br /> ------ ---- - DRINKING FOUNTAIN 1 0.5
<br /> HOSE BIBB 1 2.5
<br /> LAV SINKS 4 4.0 }�
<br /> I I LAUNDRY SINK 1 1.5
<br /> I
<br /> WATER CLOSETS 4 10.0
<br /> 02 - SHAMPOO SINKS 3 3.0
<br /> i
<br /> A4.0 I i TOTAL 32.0 E �
<br /> i
<br /> WATER PRESSURE 40 TO 60 PSI
<br /> 80'WATER RUN AT 32.0 FIXTURE UNITS O O
<br /> }♦ DC
<br /> METER AT 1 Yd'WATER SERVICE
<br /> 1 Ya"RP DEVICE °
<br /> O � •�
<br /> I oc J °
<br /> i �
<br /> ' --_ • 3 v
<br /> ENERGY NOTES to 0 r
<br /> _ _
<br /> 1. DOMESTIC HOT WATER HEATERS SHALL BE CERTIFIED AND LISTED BY THE CALIFORNIA ENERGY W Y
<br /> 1 COMMISSION. • U
<br /> EXCEPTION: NON-STORAGE TYPE ELECTRIC WATER HEATERS. °
<br /> 2. ALL HOT WATER PIPING SHALL BE INSULATED IN ACCORDANCE WITH THE TABLS BELOW. �� M N
<br /> 3. SERVICE WATER HEATING SYSTEM SHALL BE EQUIPPED WITH AUTOMATIC TEMPERATURE CONTROLS
<br /> I 1 OV INSTANT HOT CAPABLE OF ADJUSTMENT FROM THE LOWEST TO THE HIGHEST ACCEPTABLE TEMPERATURE SETTING FOR Q Q
<br /> 70 1 THE INTENDED USE, AS LISTED IN TABLE 3, CHAPTER 54 OF THE ASHRAE HANDBOOK, HVAC SYSTEMS
<br /> WATER HEATER APPLICATION VOLUME.
<br /> G 4. LAVATORY FAUCETS AND SINKS (NOT INCLUDING SERVICE SINK FAUCET) SHALL MEET THE FLOW
<br /> tZ REQUIREMENTS OUTLINED IN THE APPLIANCE EFFICIENCY STANDARDS. � ,y
<br /> 1 5. LAVATORIES IN PUBLIC RESTROOMS SHALL HAVE HOT WATER CONTROLS THAT COMPLY WITH THE
<br /> FOLLOWING REQUIREMENTS:
<br /> O 1) MAXIMUM FLOW RATE(GPM):0.5;OR 0.75(WITH A DEVICE THAT LIMITS THE
<br /> oa SS C�r.O. TIE IN TO EXISTING
<br /> - - - - - PERIOD OF WATER DISCHARGE,I.E.FOOT SWITCH OR OCCUPANCY SENSOR.
<br /> II WATER SUPPLY 2) FLOW RATE(GAL/CYCLE) FOR SELF-CLOSING VALVES: 0.25 0
<br /> 4 CNS CIRCULATING;OR 0.5 NON-CIRCULATING;OR 0.75(WITH A DEVICE THAT LIMITS THE PERIOD
<br /> 3 OF WATER DISCHARGE,I.E.FOOT SWITCH OR OCCUPANCY SENSOR.
<br /> 3) MAXIMUM OUTLET TEMERATURE: 1 10°F.
<br /> (�/I HOT WATER INSULATION REQUIREMENT
<br /> O N 1 W DOMESTIC HOT WATER SUPPLY AND RETURN PIPING SHALL BE INSULATED
<br /> THICKNESS TO COMPLY WITH TABLE BELOW:
<br /> z I (�/ KLU
<br /> o O W WATER RUNOUTS 1"OR 1 1/4 TO 2 1/2 TO 5 AND
<br /> z U Z TEMP UP TO 2" LESS 2 4 6 .._j
<br /> CO �
<br /> cn (K ii INSULATION THICKNESS
<br /> ry z _ 9, 44p U
<br /> ry
<br /> X I 105-200 1/2" 1" 1" O 1 1/2" 1 1/2" l
<br /> _ I--1
<br /> 0 is) W z THE THICKNESS OF INSULATION LISTED IN TABLE ABOVE IS BASED ON MATERIAL w
<br /> - 0 HAVING THERMAL CONDUCTIVITY RANGE OF 0.24- 0.28 IN BTU-INCH PER HOUR PER SQUARE
<br /> FLAN
<br /> NORTH FOOT DEGREE F. I= O O Q� U o 0
<br /> LJ_i ADJUSTMENTS ARE REQUIRED IN INSULATION MATERIAL OUTSIDE THIS RANGE. cv
<br /> W04 'saJ � �7 � r-
<br /> CD W05 � Z � o00
<br /> Ln HOT WATER OPERATING TEMPERATURE SHALL NOT EXCEED 110 DEGREES F. a 004. ° W
<br /> W O Qcnrn
<br /> AFFROXIMATE 0 ca o, rn
<br /> S
<br /> II
<br /> Ln NORTH *RUNOUTS TO INDIVIDUAL FIXTURE NOT OVER 2"IN SIZE OR 12 FEET IN LENGTH. ago 0 CD
<br /> Electrical Schematic
<br /> sh eet contents
<br /> D
<br /> 1/4"= 1'-0 Plumbing
<br /> O
<br /> i= Schematic
<br /> U
<br /> z
<br /> O project no
<br /> U 9162024
<br /> THESE DRAWINGS ARE FOR THE drawn by
<br /> J EXPRESS USE OF checked by 1m
<br /> c i JMW/DJ
<br /> Z E.J. PLUMBING E.J. PLUMBING project architect
<br /> 3 STATEMENT OF RESPONSIBILITY 2310 Fay Drive
<br /> E.J.PLUMBING SHALL CHECK AND VERIFY ALL ASPECTS OF DESIGN/ENGINEERING,AND SHALL ENSURE THAT ALL WORK CONFORMS Atwater, Ca. 95301
<br /> n 3 TO CURRENT CODES AND INDUSTRY STANDARDS. E.J.PLUMBING SHALL BE RESPONSIBLE FOR ALL ENGINEERING AND DRAWINGS 209-589-5742 plot date 06242024
<br /> AND SHALL PLACE HIS OR HER NAME,SIGNATURE, LICENSE NUMBER AND DATE ON THE CONSTRUCTION DRAWINGS SO AS TO sheet number
<br /> } O INDICATE SUCH RESPONSIBILITY (PRIOR TO START OF WORK) . ANY MODIFICATIONS To THE DRAWINGS,CALCULATIONS,OR FIELD
<br /> CONDITIONS SHALL BE E.J.PLUMBING RESPONSIBILITY. BY BEGINNING WORK,E.J.PLUMBING AGREES TO THE ABOVE STATEMENT OF
<br /> a> 0 RESPONSIBILITY. ALL OTHER USE BY WRITTEN MEP DISCLAIMER:
<br /> N PERMISSION ONLY OF
<br /> JMWELLS DESIGN is not a engineering firm. The mep design/system and and/or elements,either noted or implied,are foreg neral
<br /> Uuideline purposes only. These drawings have not been reviewed by a licensed Engineer, (unless an official stamp of an licensedmepi
<br /> 0 o EJ E.J. PLUMBING engineer appears on these drawings). it is the responsibility of the owner and General Contractor to obtain the services of a licensed •
<br /> Q = 683610 Engineer to review these drawings prior to construction. By accepting these drawings,JMWELLS Designer/Jack Wells is released from
<br /> a: all liability for any MEP defects and/or failures.
<br /> PRINTED NAME LICENSE NUMBER DATE SIGNATURE Of
<br /> 0 - -
<br />
|