Laserfiche WebLink
Table 2CDCR-EW-3 Step Test ResultsWell Installation and Interim Remedial Action ReportCalifornia Department of Corrections and RehabilitationStockton, CaliforniaTime (minutes)Pumping Rate (gpm)Depth to Water (ft btoc)Drawdown (ft)Water Column in Wella (ft)Percentage Water Column Drawdown Water Column Above Screen (ft)Specific Capacity (gal/ft drawdown)Average Specific Capacity per StepStatic0 0 60.55 0.00 55.45 0% 20.45 -- --5 5.1 61.91 1.36 54.09 2% 19.09 3.815 5.1 61.95 1.40 54.05 3% 19.05 3.620 5.1 61.98 1.43 54.02 3% 19.02 3.625 10.0 64.02 3.47 51.98 6% 16.98 2.935 10.0 64.24 3.69 51.76 7% 16.76 2.740 10.0 64.28 3.73 51.72 7% 16.72 2.745 20.4 70.91 10.36 45.09 19% 10.09 2.055 20.3 71.79 11.24 44.21 20% 9.21 1.860 20.3 71.91 11.36 44.09 20% 9.09 1.870 23.9 74.00 13.45 42.00 24% 7.00 1.8130 24.2 74.00 13.45 42.00 24% 7.00 1.8190 24.1 74.00 13.45 42.00 24% 7.00 1.8Notes:a The water column is measured from depth to water to the bottom of the screen and does not include the well sumpb Step 4 was added from the constant rate test dataset.Acronyms and Abbreviations:-- = not applicablebtoc = below top of casingCDCR = California Department of Corrections and Rehabilitationft = feetgal/ft drawdown = gallon per foot of drawdowngpm = gallon per minuteStep 4b1.8Step 13.7Step 22.8Step 31.9Page 1 of 1